- Phone
-
Address
Shanghai Xingyun Economic Zone
Shanghai Zike Valve Manufacturing Co., Ltd
Shanghai Xingyun Economic Zone

|
ZKYC7201 Electric Differential Pressure Bypass Valvefunction Electric differential pressure control bypass valveIt is achieved by controlling the opening of the pressure difference bypass valve to regulate the bypass flow rate of chilled water, thereby maintaining a constant pressure difference at both ends of the supply and return water main pipes. Widely used between central air conditioning water collectors and between heat pump supply and return water, it can effectively prevent equipment from being damaged Electric differential pressure control bypass valveCommonly used in gas or liquid systems to control the pressure difference between gas or liquid pipelines and circuits. Install the electric pressure differential bypass valve in the bypass pipeline of the system water pump accessory. When the system pressure differential increases and exceeds the set value of the control valve, the valve will open further, allowing more water to flow through the bypass valve and reducing the system pressure differential. On the contrary, the decrease in pressure difference leads to a decrease in valve opening, resulting in an increase in system pressure difference. This system is suitable for pressure differential bypass control of chilled water/hot water systems in central air conditioning. working principle
Introduction to differential bypass valve, electric differential pressure bypass valve, and electric differential pressure regulating valve Differential pressure bypass valve, electric differential pressure bypass valve, and electric differential pressure regulating valve control the bypass flow of chilled water by controlling the opening of the differential pressure bypass valve, thereby maintaining a constant pressure difference at both ends of the supply and return water main pipe. Widely used between central air conditioning water collectors and between heat pump supply and return water, it can effectively prevent equipment from being damaged.
Differential pressure bypass valve, electric differential pressure bypass valve, electric differential pressure regulating valveThe application Electric differential pressure bypass valves are commonly used in gas or liquid systems to control the pressure difference between gas or liquid pipelines and circuits. Install the electric pressure differential bypass valve in the bypass pipeline of the system water pump accessory. When the system pressure differential increases and exceeds the set value of the control valve, the valve will open further, allowing more water to flow through the bypass valve and reducing the system pressure differential. On the contrary, the decrease in pressure difference leads to a decrease in valve opening, resulting in an increase in system pressure difference.
|