Eight row centrifuge

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Eight row centrifuge: compact structure, fast operation, efficient functionality, and economical price. It comprehensively considers the needs of various aspects in the use of micro centrifuges and presents performance in every aspect. This centrifuge is very suitable for micro tube filtration and rapid centrifugation, separation of trace blood cells, microbial sample processing, PCR, small volume cell separation, separation of HPLC samples, and prevention of liquid wall hanging in centrifuge tubes. It is a good helper for processing small batch centrifuge samples

Product Details

Eight row arrangementIntroduction to Centrifuge:

Eight row arrangementcentrifugeCompact structure, fast operation, and cost-effective functionality, it comprehensively considers the needs of various aspects in the use of micro centrifuges and presents performance in every aspect. This centrifuge is very suitable for micro tube filtration and rapid centrifugation, separation of trace blood cells, microbial sample processing, PCR, small volume cell separation, separation of HPLC samples, and prevention of liquid wall hanging in centrifuge tubes. It is a good helper for processing small batch centrifuge samples

Product characteristics of centrifuge:

1: Adjustable speed: Speed range: 500-12000rpm,

2: Drive mode: Abson DC permanent magnet motor*

3: Display mode: LCD screen simultaneously displays speed and time

4: Smart rotor buckle design: rotor replacement requires no auxiliary tools, convenient and fast

5: Timer function: Effective centrifugation time range: 1-99 minutes or 1-59 seconds; Facilitating the accuracy of experiments

6: Security of:Real time monitoring of the centrifugation process is possible to ensure the safe operation of the instrument

7: Process materials: can resist various chemical corrosion, and the rotary head has high temperature resistance and disinfection function

8: Efficient speed control:Faster acceleration/deceleration rates to complete experiments in a shorter amount of time

9: Multifunctionality: Novel composite test tube rotors and compatibility with more test tube rotors to meet basic experimental needs

10: Exquisite design: The airflow design also greatly reduces the temperature rise of the sample during high-speed centrifugation

11: Humanized design: End of operation, error and imbalance, sound signal prompt, stop operation at the same time, LCD display code

Main technical parameters:

Product Model

SmartFuge

Speed [r/min.]

500~12000rpm

Relative centrifugal force [× g]

9700×g

Speed step increase

500rpm

timing range

1-99min. /1-59sec.

Speed deviation

±5%

Control method

ST16 bit MCU/PWM/speed regulation;

display mode

Abson black background white text LCD

Drive Type

Abson DC permanent magnet motor

operation method

Touch button operation

Misoperation/malfunction alarm

Sound prompt+display code

Rotor configuration

SG-B: 1.5/2.2ml x 12+0.2ml x 8 holes x 4 rows/adapter 0.5/0.2ml x 12 (standard)

SG-C: PCR tube swivel 0.2ml x 12 holes x 4 rows (standard)

SG-D: Angle rotary head 5ml x 4 holes/cone bottom connecting tube/adapter 1.8/1.1ml x 4 pieces (optional)

SG-E: capillary specific volume rotary head; Diameter 1.5 x Length 40 Capillary Tubes x 12/Blood Volume Rotary Head Reading Card (optional)

Dimensions: Length x Width x Height [mm]

190×230×120

Weight (without rotor)

2Kg

Noise at RPM

≤47dB(A)

accelerate time

≤12s

deceleration time

≤16s

protection level

IP21

Allow ambient temperature/relative humidity

5-40℃/80%

Power fuse tube

PPTC/Self healing fuse/No need to replace

input power

AC85-264V/50/60Hz

input power

40W

Testing Standard

EN 61010-1,EN 61010-2-020,EN 61326-1,EN 61010-3-2/A2

Transform*

Capacity ml x number of tubes

Speed (r/min.)

Relative centrifugal force (× g)

Test tube type

Composite rotor

1.5/2.2 × 12+CCR0.2 × 8 × 4 rows

12000

9700

PP cone bottom with cover

PCR rotor

PCR0.2 × 12 × 4 rows

12000

5960

PP cone bottom with cover

Angular rotor

5×4

12000

9660

PP cone bottom with cover

Angular rotor

Capillary hematocrit tube × 12

12000

8371

Diameter 1.5mm × 40

Angular rotor

5/1.8/1.1×4

7000

3180

PP can stand screw mouth pipe

configuration information

SG-1

host

SG-2

1.5/2.2ml x 12+PCR 0.2ml x 8 holes x 4 rows/adapter 0.5ml/0.2ml x 12

standard configuration

SG-3

PCR pipette tip 0.2ml x 12 wells x 4 rows

standard configuration

SG-4

Angle rotary head 5ml x 4 holes/cone bottom cover tube/adapter 1.8/1.1ml x 4 pieces

optional

SG-5

Capillary hematocrit turning head; Diameter 1.5mm x Length 40mm Capillary Tube x 12/Blood Volume Rotary Head Reading Card

optional

Operation and usage instructions

Attention: Before using the instrument, please ensure that there is no damage during transportation!

*Is the appearance of the instrument brand new and intact!

*Is it easy to open the transparent cover opening lever without any abnormal sound!

*Is the rotor elastic buckle vertically and tightly fitted on the motor spindle!

*Is the edge of the shock absorber pad firmly stuck on the main body shell!

*Is the power switch and power cord securely fixed to the main body casing without any looseness!

*If none of the above phenomena occur, the instrument can be safely used*

If any of the above situations occur, please contact the manufacturer or authorized dealer in a timely manner. Do not repair without the guidance of professional maintenance personnel!

4.1 [Open/Close Cover]

  • Maintenance and upkeep matters

Do not attempt to clean the centrifuge when the power cord is plugged in or the power switch is turned on. If the equipment or accessories are contaminated by pathogenic, toxic, or radioactive substances, it is the responsibility of the user to carry out appropriate purification, which should be explained when developing the "Laboratory Biosafety Manual" and so on. When there are other requirements for cleaning and decontamination besides those mentioned in this chapter, please contact our company to check if they may damage the equipment. If you plan to return the equipment or accessories to our company or request repairs, you must ensure that the equipment or accessories are clean and not harmful to human health!

Organic solvents should not be used as they can decompose the lubricating grease inside the motor bearings; During the cleaning process, liquids, especially organic solvents, should not come into contact with the motor spindle and the ball bearings inside the bearings!

5.1Do not use sharp objects to collide with the rotor. During handling and disassembly, prevent collision and prevent cracks from occurring in the rotor due to scratches or external injuries.

5.2 Regularly inspect the rotor components (especially the bottom of the test tube hole) for corrosion spots, grooves, and small cracks. If any of the above conditions are found, please stop using the rotor and contact the production unit.

When disassembling the rotor, grab it with both hands and lift it vertically upwards without shaking it left or right!

5.3Normally, the rotor should be cleaned once a week. If separating salt solution or other corrosive samples, please clean it immediately after use. If the sample is found to splash, soak or drip onto the rotor during use, it should be immediately dried and locally cleaned.

5.4When cleaning the rotor, please wet a sponge or cloth with neutral cleaning agent, and then wash off the cleaning agent with distilled water. Do not sprinkle or spray the rotor with water, as the liquid may leave a certain area and cause corrosion. After cleaning, it is allowed to air dry upside down.

5.5Check the locking condition of the transparent cover and the main body shell to ensure smooth opening and closing of the cover.

5.6Carefully wipe the surface of the instrument with a soft cloth dipped in neutral detergent, and then remove the detergent with a clean damp cloth.

5.7 If there is a major problem with the instrument, such as the inability to operate under normal power supply, the smell of burning inside the machine, the broken rotor, or severe shaking during instrument operation, etc