- Phone
-
Address
158 Baoxiang Road, Jiading District, Shanghai
Shanghai Shengxu Electric Co., Ltd
158 Baoxiang Road, Jiading District, Shanghai
ETCR2000 Clamp on Grounding Resistance TesterThe 2025 model is an upgraded version of the ETCR2000A, with a brand new appearance and a return to red and gray design. The instrument panel is more compact and lightweight, and has added sound and light alarm functions.
The clamp shaped grounding resistance tester is controlled by a microprocessor and can accurately detect grounding resistance. It uses fast filtering technology to minimize interference. Simultaneously providing functions such as data storage and data upload.
1、 Product function grounding resistance test and circuit resistance test.
2、 Product Features 1 A major breakthrough in grounding resistance testing technology and fast and safe non-contact measurement. When measuring a grounding system with a circuit, there is no need to disconnect the grounding lead or auxiliary grounding electrode, saving time and effort. 3. The clamp type grounding resistance meter can measure grounding faults that cannot be measured by traditional methods, and can be applied in situations where traditional methods cannot measure them. 4. Sound and light alarm function, data storage, and data retention function.
IIIETCR2000 Clamp on Grounding Resistance TesterTechnical Specifications
Product model |
ETCR2000 clamp type grounding resistance meter |
ETCR2000A clamp type grounding resistance meter |
ETCR2000C clamp type grounding resistance meter |
resistance range |
0.010Ω to 1000Ω |
0.010Ω to 200Ω |
0.010Ω to 1000Ω |
current range |
- |
- |
0.00mA~30.0A |
Resistance measurement accuracy |
measurement range |
resolution |
accuracy |
0.010Ω-0.099Ω |
0.001Ω |
±(1%rdg+0.01Ω) |
|
0.10Ω-0.99Ω |
0.01Ω |
±(1%rdg+0.01Ω) |
|
1.0Ω-49.9Ω |
0.1Ω |
±(1%rdg+0.1Ω) |
|
50.0Ω-99.5Ω |
0.5Ω |
±(1.5%rdg+0.5Ω) |
|
100Ω-199Ω |
1Ω |
±(2%rdg+1Ω) |
|
200Ω-395Ω |
5Ω |
±(5%rdg+5Ω) |
|
400Ω-590Ω |
10Ω |
±(10%rdg+10Ω) |
|
600Ω-1000Ω |
20Ω |
±(20%rdg+20Ω) |
|
Accuracy of current measurement |
0.00mA-9.99mA |
0.01mA |
±(2.5%rdg+1mA) |
10.0mA-99.9mA |
0.1mA |
±(2.5%rdg+5mA) |
|
100mA-299mA |
1mA |
±(2.5%rdg+10mA) |
|
0.30A-2.99A |
0.01A |
±(2.5%rdg+0.1A) |
|
3.0A-9.9A |
0.1 A |
±(2.5%rdg+0.3A) |
|
10.0A-19.9A |
0.1 A |
±(2.5%rdg+0.5A) |
|
20.0A-30.0A |
0.1 A |
±(3%rdg+1A) |
|
Jaw size |
55mm×32mm |
||
Clamp gauge size |
277mm×100mm×57mm |
||
Clamp gauge quality |
About 1.6kg (including accessories)
|
||
Power supply |
DC6V, No.5 alkaline dry battery (LR6 1.5V × 4) |
||
Single measurement time |
0.5 seconds |
||
liquid crystal display |
4-digit LCD digital display, length and width 47mm × 28.5mm |
||
data storage |
99 groups |
||
audible and visual alarm |
Beep beep beep beep "alarm sound |
||
Alarm threshold setting range |
Resistance: 1-199 Ω; *Current: 1-499mA (limited to C-type) |
||
Jaw opening size |
32mm |
||
protection level |
Double insulation
|
||
Shift gears |
Fully automatic gear shifting |
||
Random attachment |
Clamp gauge: 1 piece; Test loop: 1 piece; LR6 battery: 4 cells; Instrument box: 1 piece |
||