EP600Type infrared spectrophotometer oil analyzer
1Compliant with standards
Compliant with national standards“HJ637-2012Water quality - Determination of petroleum, animal and vegetable oils - Infrared photometric method”
2Department using the instrument
Environmental monitoring systems, petrochemicals, hydrology and water conservancy, tap water, sewage treatment plants, thermal power plants, steel enterprises, scientific research and teaching in universities, agricultural environmental monitoring, railway environmental monitoring, automobile manufacturing, marine environmental monitoring, transportation environmental monitoring, environmental research and other testing rooms and laboratories are used.
3Technical indicators
detection limit3SD≤0.04mg/L(measurement11Secondary blank calculation3Multiple standard deviation)
Minimum detectable concentration0.001mg/L
Maximum measured concentration pure oil
Basic measurement range0.0-800mg/L
repetitivenessRSD≤0.5%(30-100mg/LOil sample determination11time)
Accuracy error<2%
correlation coefficientR>0.999
scanning speed Full spectrum scanning,30second/time
wavenumber range3400cm-1~2400cm-1(i.e2941nm~4167nm)
Range of absorbance 0.0000~2.0000AU(i.e. transmittance)100~1%T)
Wave number accuracy and repeatability ±1cm-1
Measure tetrachloroethylene2930cm-1 Absorbance: <0.2(A)
Aromatic hydrocarbon detection limit2mg/L(National standard substance for benzene)
Use temperature and humidity temperature range1℃-40℃, humidity≤90﹪
external dimensions45cm×35cm×13cm(Length, Width, Height)
Use power supply(220±22)VThe(50±1)HzThe50VA
4Technical features
1. The true three wavenumber and infrared three wavenumber spectra are clear and accurately calibrated, and can clearly display the absorption spectra and absorbance generated by the three wavenumbers;
2. Capable of measuring instrument calibration coefficient function;
3. Can test the transmittance and purity of extractants, and distinguish various interferences;
4. adoptedNCInfrared light source, long lifespan, can be illuminated by other types of light;
5. Electric modulation light source, replacing mechanical switching light source, simplifies structure, and improves performance;
6. The thermal sensitive photodetector collects dual signals when the light source is on or off, achieving automatic adjustment of the zero point of infrared light at any time;
7. adoptWindows XPorwin7Operating system control;
8. Other non hydrocarbon organic solvents such as tetrachloroethylene and trichlorotrifluoroethane can be used as extractants;
9. It has functions such as automatic statistical analysis, spectrum display, storage, and printing.
10. Detachable integrated optical system, small size, short optical path, high energy, first splitting and then absorbing, good stability.