1、 Overview:
EN085-M10-15M-20-GB piezoelectric vibration sensorIntegrating vibration velocity sensors and measurement circuits together to achieve traditional 'sensors'+The vibration measurement system function of the "monitoring instrument" mode is suitable for building an economical vibration measurement system. This transmitter can be directly connectedDCSThePLCOr other systems, such as fans The ideal choice for vibration measurement of factory equipment such as water pumps.
Unit type: various rotating machinery. Such as fans, compressors, motors, pumps, gearboxes, water turbines, etc.
Installation requirements for the probe: only need to make a φ on the casing35mmThe platform, openM10×1.5Screw hole, fix the probe on the screw hole without any operation inside the machine.
2、 Electrical indicators:
Working voltage:DC24V
frequency response: (±3dB)
bit Move:2-3.0KHz±8%
fast Degree:5-300Hz±8%
Range: Vibration Intensity0-50.0mm/sVibration displacement0-500um
Current output:4~20mAOutput load:<500Ω
Input signal: Built in vibration speed sensor signal
spirit Min Degree:20mv/mm/s±5%

3、 Physical indicators:
Dimensions: φ35×75mm
Installation method: fixed with screwsM10×1.5deep10mm(Customizable)
heavy Quantity: Approximately350g
Measurement direction: vertical or horizontal (universal)
4、 Environmental indicators:
Wen Temperature: Operating Temperature-25℃ to+60℃, storage temperature-30℃ to+70℃。
relative humidity ≤90%,No strong magnetic interference
5、 Installation requirements and methods
Connect the integrated vibration transmitter to the measured object, and the fixing method is generally to use the manufacturer's double headed screw to fix one end in the center hole of the sensor base and the other end in a suitable position on the bearing cover of the rotating machinery, and avoid installation in excessively humid places (if the environment is harsh, a protective cover can be ordered from the manufacturer). To eliminate on-site interference, shielded cables must be used, and one end of the shielding layer must be grounded.
6、 Precautions
Installed at vibration sensitive points, points closest to the core, and vulnerable points of the machine. The measurement point should be as close as possible to the load-bearing area and have sufficient rigidity, and the base of the sensor should be in close contact with the measured object.
During transportation and installation of sensors, unnecessary vibrations and impacts should be avoided as much as possible.
When it is inconvenient to drill holes for sensors on site, a magnetic seat can be used for installation.