ELCOMETR/UK Yigao Coating Thickness GaugeDetailed introduction of the Jigs456:
ELCOMETR/UK Yigao Coating Thickness GaugeElcometer456, This is a high-precision dry film thickness measurement equipment widely used for industrial coating inspection, supporting iron-based/non-ferrous/dual-use measurement, available in integral and split types, and with three functional levels B, S, and T to choose from.

Model and Form Classification
1. Functional level
Basic Type (B): Meets basic thickness measurement without advanced statistics/alphanumeric batch management;
Standard type (S): increases data storage, Bluetooth/USB transmission, and multiple calibration modes;
Advanced type (T): equipped with complete statistics, over limit alarm, alphanumeric batch naming, and comprehensive data export capabilities.
2. Measuring substrates: iron-based (F, magnetic induction), non-ferrous (N, eddy current), dual-purpose (FNF, dual principle automatic switching);
3. Form
Integrated: Built in Bigfoot probe, stable one handed operation, suitable for routine flat detection;
Split type: can be equipped with various probes including straight/right angle/micro/telescopic/high temperature/underwater, suitable for narrow, irregular, and harsh environments, with a range of up to 31mm (1220mils).

Core technical parameters
1. Display and operation: 2.4-inch QVGA color TFT screen (320 × 240 pixels), automatic rotation, multilingual menu, large buttons can be operated with gloves;
2. Measurement accuracy: The overall range of 1 (0-1500 μ m) is ± 1-3% or ± 2.5 μ m (whichever is greater); Resolution of 0.1 μ m (0-100 μ m), 1 μ m (100 μ m+);
3. Reading speed: 70+/minute, scanning probe can reach 140+/minute;
4. Data storage: up to 150000 readings, 2500 batches;
5. Interface: USB+Bluetooth, compatible with ElcoMaster software and mobile app, one click to generate professional reports;
6. Power supply: 2 AA batteries, working continuously for about 24 hours;
7. Protection and Environment: IP64 dustproof, waterproof, impact resistant; Working temperature -10 ℃~50 ℃;
8. Size and weight: 141 × 73 × 37mm, 161g (including battery).
Key functional highlights
Thermal stability measurement algorithm to maintain accuracy in temperature fluctuating environments;
Multiple calibration modes (zero point, smooth two-point, rough/two-point, automatic calibration), supporting storage of multiple sets of calibration data;
High/low limit setting, visual alarm for exceeding limit;
Split type can be converted from PINIP to integral type, balancing flexibility and stability;
Meets dozens of international testing standards such as ASTM, ISO, BS, EN, etc;
Factory calibrated, with traceable certificate, warranty period of 1 year (registration within 60 days can be extended to 2 years).
Typical application scenarios
Industrial anti-corrosion: testing of coatings/galvanized layers on steel structures, pipelines, pressure vessels, and bridges;
Automobile manufacturing/maintenance: Testing of body paint film thickness;
Ship and Ocean Engineering: Painting and Acceptance of Ship hulls, cabins, and offshore platforms;
Aerospace: Control of surface coating and anodizing layer thickness on components;
Electronics and Home Appliances: Metal Shell Spray Coating/Spray Coating Thickness Measurement.

Suggestions for overall and split type selection
| selection | advantage | Applicable scenarios |
|---|---|---|
| monolithic | Portable, one handed operation, price friendly | Large area flat panel and regular production line sampling inspection |
| split-type | Probe interchangeable, wide range, adaptable to irregular shapes/high temperatures/underwater environments | Equipment internal holes, welds, storage tanks, high-temperature workpieces, underwater structures |