- Phone
-
Address
Changping District, Beijing
Beijing Jiuzhou Pengyue Technology Co., Ltd
Changping District, Beijing
Detection principle: Extraction type, with automatic blowback function, communicating with DCS through Modbus TCP protocol, power supply 220VAC, equipped with radiation monitoring instrument, and shielded steel box. The device adopts negative pressure suction and comes with a compressed air injector. Sampling and exhaust pipe specifications: φ 14 * 2, stainless steel 304L. Complete cabinet installation, cabinet material: stainless steel 304L. Comes with installation bracket and connecting accessories. Environmental protection level: IP54.
Measurement objects: industrial waste gas, smoke, dust
Measurement principle: Based on the principle of forward light scattering, the highly stable laser emitted by the laser is collimated and then injectedThe measurement room generates forward scattered light when the laser beam meets the particles. The scattered light is received by a lens and transmitted through a signalThe optical fiber is imported into the photodetector.After ultra-high sensitivity photoelectric signal conversion, the scattered light signal is transformed into a telecommunication signal proportional to the concentration of particulate matterNumber, output the concentration value of particulate matter through a specific algorithm.Extraction heating return gas path structure, which can be used in situations where the measured gas contains water mist;Optical path structure, with extremely high sensitivity and resolution;Automatic zero point and automatic span calibration; Technology: Jiuzhou Pengyue Zhang Haitao
The structure and calculation method of the blowback and air curtain held, resistant to window pollution;
Industry applications: Online monitoring of emissions (thermal power, steel, metallurgy, cement, petrochemical, ceramics, aluminum, nuclear)Electricity can also be widely used for continuous measurement of particulate matter in process control, hygiene, safety, scientific research, and other fieldsVenue
Execution standard:HJ/T 76-2007Technical requirements and testing methods for continuous monitoring system of national pollution source emissions of flue gaslawTechnical parameters
Working principle: Laser forward scattering measurement principle
Sampling method: extraction type, sampling tube and exhaust tube specifications: φ14*2Stainless steel304L
Measurement objects: industrial waste gas, smoke, dust
Measurement range: minimum(0~5-10) (mg/m3), maximum(0-1000) (mg/m3 )
Zero drift:±2%F.S./24hRange drift:±2%F.S./24hIndication error±10%F.S.Weighing methodDetection limit:0.01mg/m³Flue diameter:(2~20)m
Resolution ability: superior to0.005mg/m3Analog output:4-20(mA)(Maximum output load)500)Digital output:RS485(Support)ModbusAgreement)Flue diameter:(0.3-20)RiceSmoke flow rate:(0-40)m/sFlue pressure:(-5~5)kPaSmoke temperature:≤300℃
Smoke humidity:≤300g/mAnti blocking reverse blowing: automatic, reverse blowing time interval can be setBackblowing setting: Automatic (Backblowing time interval can be set by oneself)
Protection level: SystemIP65
Power Supply:220ACThe600WOverall dimensions:
Host:675mm*490mm*265mm