Welcome Customer !

Membership

Help

Shanghai Naiai Precision Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Naiai Precision Instrument Co., Ltd

  • E-mail

    nai17@foxmail.com

  • Phone

    13817078549

  • Address

    Building 1, No. 139 Rongmei Road, Songjiang District, Shanghai

Contact Now

Dry nitrogen blower - electric type

NegotiableUpdate on 04/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

NAI-DCY-12GD, NAI-DCY-24GD. Currently, the specifications of the electric dry nitrogen blowing instrument are 12 holes and 24 holes (with manual adjustment of the dry nitrogen blowing instrument). Note: The default diameter for sample tube processing is 16mm (tubes larger than 16mm can be customized). Product description: The electric dry nitrogen blowing instrument NAI-DCY-12GD, 24GD adopts blowing and trapping technology, and can also control the temperature and heat of the sample. Inert gases such as nitrogen are quickly, controllably, and continuously blown onto the surface of the sample to achieve rapid anaerobic concentration of the sample solution. Dry nitrogen blowing apparatus is mainly used for the concentration preparation of large quantities of samples, such as in the fields of pharmaceuticals, medical testing, pesticide residue detection, drug screening, hormone analysis, liquid phase, gas phase, and mass spectrometry analysis for sample preparation Application range: 1. Pesticide analysis: vegetables, fruits, grains, plant tissues, etc. 2. Pharmaceutical testing: traditional Chinese medicine pharmaceuticals and drug testing 3. Environmental analysis: drinking water, groundwater, polluted water, etc. 4. Biological analysis: serum, plasma, blood, urine, etc. 5. Product testing: testing for dioxins, Croats, etc. 6. Food and beverage: milk, alcohol, liquid beverages Main characteristics Principal character: 1. Each blowing needle can be independently controlled to avoid cross contamination. The height of the instrument's air chamber can be adjusted by itself, and it is equipped with a standard air needle length of 15 centimeters. 2. NAI-DCY-12GD and 24GD have 12 or 24 airway control switches to save gas, and each blowing needle is equipped with .....

Product Details

NAI-DCY-12GD ,NAI-DCY-24GDcurrentlyelectricdrySpecification of nitrogen blowing instrument: 12 holes, 24 holes (with manual adjustment of dry nitrogen blowing instrument available)

Note: Sample tube processing default diameter: 16mm (tubes larger than 16mm can be customized)


DESCRIPTION Product description



Electric dry nitrogen blowerNAI-DCY-12GD,24GDBy using blow sweep capture technology and temperature controlled heating of the sample, inert gases such as nitrogen are rapidly, controllably, and continuously blown onto the surface of the sample to achieve rapid anaerobic concentration of the sample solution.Dry nitrogen blowerMainly used for concentrated preparation of large quantities of samples, such as in the fields of pharmaceuticals, medical testing, pesticide residue detection, drug screening, hormone analysis, liquid phase, gas phase, and mass spectrometry analysis for sample preparation

Application scope Application range



1. Pesticide analysis: vegetables, fruits, grains, plant tissues, etc

2. Pharmaceutical inspection: Traditional Chinese Medicine pharmaceuticals and drug testing

3. Environmental analysis: drinking water, groundwater, polluted water, etc

4. Bioanalysis: Serum, plasma, blood, urine

5. Product inspection: Inspection of dioxins, Croods, etc

6. Food and beverages: milk, alcohol, liquid beverages

Main features Principal character



1. Each blowing needle can be independently controlled to avoid cross contamination. The height of the instrument's air chamber can be adjusted by itself, and it is equipped with a standard air needle length of 15 centimeters.

2. NAI-DCY-12GD and 24GD have 12 or 24 airway control switches to save gas, and the position of each blowing needle can be independently changed for blowing.

3. When concentrating toxic solvents, the entire system can be placed in a fume hood to reduce danger.

4. Built in over temperature protection device, automatic fault detection and alarm function, convenient to use.

5. LED display screen, temperature synchronous display, time decreasing display, can observe temperature changes in real time.

Technical Parameter Technical parameter



1. Operating environment temperature: 5 ° C~30 ° CRelative humidity: ≤ 70%

2. Power supply: AC220V~50-60Hz

3. Temperature range: Room temperature+5 ° C~150 ° C

4. Timed time: 99 hours and 59 minutes in duration

5. Temperature control accuracy: ≤± 0.5 ° C

6. Display accuracy: ± 0.1 ° C

7. Temperature uniformity: 40~100 ° C ≤± 0.5 ° C

8. Temperature uniformity: 100~150 ° C ≤± 1 ° C

9. Heating time (40-150 ° C): ≤ 30 minutes

10. Maximum lifting stroke: 200mm Maximum gas flow rate: 15L/min


Model Selection Model selection


PRODUCT MODEL NAI-DCY-12GD NAI-DCY-24GD
Number of processed samples 12 independent controls 24 independent controls
Number of modules 1 piece 2 of them
Power 150W 300W
fuse 250V 3A Ф5×20 250V 4A Ф5×20
precision ±0.5℃ ±0.5℃
Maximum lifting stroke 200mm (electric) 200mm (electric)
Dimensions (mm) 280X240X500 280X240X500
Timed Time 0~99h59min 0~99h59min
gas flow Controllable 0-15L/min Controllable 0-15L/min
Maximum gas pressure 0.02Mpa (using ≤ 16 air needles) 0.05Mpa (using more than 16 air needles)
Needle length 80mm(Test tube)diameter10), 150mm 80mm(Test tube)diameter10), 150mm
weight 7KG 7.5KG
Test tube diameter 16mmx45mm 16mmx45mm

Option Modules Optional module



Type
Test tube diameter
Number of test tubes
Number of test tubes
MK01
10mm
12 24
MK02
12mm
12
24
MK03
13mm
12
24
MK04
15mm
12
24
MK05
16mm
12
24
MK06
19mm
12
24
MK07
20mm
12
24
MK08
26mm
12
24
MK09
1500mm
12
24
MK10
2000mm
12
24


NAI dry nitrogen blower|Quotation for dry nitrogen blowing instrument|Dry bath nitrogen blower | Dry heat nitrogen blower quotation | Dry nitrogen blower quotation


 4.1文案-干式-电动.jpg