NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The main technical parameters of the drug melting point testing machine are as follows: $r $n1. Melting point measurement range: 40 ℃~280 ℃ $r $n2. Melting point display mode: LCD display $r $n3. Temperature digital display minimum display value: 0.1 ℃ $r $n4. Measurement indication error: amp; amp; amp; Within the temperature range of 200 ℃:; amp; amp; amp; #177; Within the range of 0.5 ℃ ≥ 200 ℃:; amp; amp; amp; #177; 0.8℃

Product Details

Drug melting point testing machineThe main technical parameters are as follows:

1. Melting point measurement range: 40 ℃~280 ℃

2. Melting point display method: LCD display

3. Minimum temperature display value: 0.1 ℃

4. Measurement indication error: within the range of<200 ℃: ± 0.5 ℃ ≥ 200 ℃: ± 0.8 ℃

5. Repeatability: 0.3 ℃ at a heating rate of 1.0 ℃/min

6. Initial temperature setting error: ± 1 ℃

7. Linear heating rate: four levels: 0.5 ℃/min, 1.0 ℃/min, 1.5 ℃/min, 3 ℃/min

8. Linear heating rate error: 10%

9. Thermal conductive medium: Silicone oil

10. Instrument level: This instrument meets the technical requirements of level 0.5 in JJG701-1990

11. Capillary size: inner diameter: 0.90mm~1.10mm, diameter thickness: 0.10mm~0.15mm, length: 120mm

12. Sample filling height: 3mm

13. Power supply: 220V ± 22V, 50HZ ± 1HZ, 250W

14. Dimensions (length, width, height): 270mm × 310mm × 400mm

15. Mass: 12.5kg

Drug melting point testing machineThe main technical parameters are as follows:

1. Melting point measurement range: 40 ℃~280 ℃

2. Melting point display method: LCD display

3. Minimum temperature display value: 0.1 ℃

4. Measurement indication error: within the range of<200 ℃: ± 0.5 ℃ ≥ 200 ℃: ± 0.8 ℃

5. Repeatability: 0.3 ℃ at a heating rate of 1.0 ℃/min

6. Initial temperature setting error: ± 1 ℃

7. Linear heating rate: four levels: 0.5 ℃/min, 1.0 ℃/min, 1.5 ℃/min, 3 ℃/min

8. Linear heating rate error: 10%

9. Thermal conductive medium: Silicone oil

10. Instrument level: This instrument meets the technical requirements of level 0.5 in JJG701-1990

11. Capillary size: inner diameter: 0.90mm~1.10mm, diameter thickness: 0.10mm~0.15mm, length: 120mm

12. Sample filling height: 3mm

13. Power supply: 220V ± 22V, 50HZ ± 1HZ, 250W

14. Dimensions (length, width, height): 270mm × 310mm × 400mm

15. Mass: 12.5kg