The drop test bench is mainly suitable for testing the damage caused by product packaging when it is dropped, and evaluating the impact strength of components when they are dropped during transportation. The drop test bench conducts vertical impact tests on transport packages through free drops Suitable for electronic product packaging drops, plastic product packaging drops, toy product packaging drops, other finished product packaging drops, etc.
▲ The drop height can be preset, and when the specimen reaches the preset height, it can be automatically positioned
The release mechanism is free, flexible, and reliable, ensuring that the specimen is not affected by any external forces during the moment of release and free fall, thereby ensuring the required drop state of the specimen.
▲ Conduct inclined table impact test on transportation packaging to determine the impact force that the transportation packaging can withstand and its ability to protect the contents. This machine can perform free fall tests on the surface, corners, and edges of the packaging.
1.Drop height:300~1500mm
2.Maximum weight of test piece(kg):0-50KG
3. Bottom plate thickness: 10mm (solid iron plate, other plates can be added)
4.Maximum size of test piece(mm):800*800*1000
5.Impact panel size(mm):1700*1200
6.Arm size(mm):160*250*10
7. Drop height error: ± 10mm
8. The external dimensions of the test bench are approximately (mm): 1700 * 1200 * 2315
9. Height display; LED instrument digital display (7-inch touchscreen option)
10. Test method: surface, corner, and edge drop
11. Transmission mode: electric transmission
12.Parallel error of impact panel≤ 1 degree
13.Error in the angle between the falling surface and the horizontal during the falling process≤ 1 degree
14.power supply380V AC/3PH+N+PE/50Hz Allowable voltage fluctuation range± 10% frequency allowed fluctuation range ± 1%
15.Net weightkg):600
16.The experimental system meets the specifications:ISO2248JISZ0202-87 GB/T4857.5-92