Displacement, counting, and angle display control instruments

NegotiableUpdate on 05/22
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Displacement, counting, and angle display control instruments are equipped with resistance rulers and potentiometers. Single 6-digit LED display with a display range of -99999 to 99999. The input circuit has been optimized for the characteristics of the resistance ruler (potentiometer), resulting in improved display and measurement stability, as well as enhanced resistance to electromagnetic interference and series mode interference. 0.05 level accuracy, measurement and control speed can be set between 5-200 times per second, display range -99999 to 99999. Panel buttons and switch input setting function. Welcome to consult with all users.

Product Details

Displacement, counting, and angle display control instrumentsConnect resistance ruler and potentiometer. Single 6-digit LED display with a display range of -99999 to 99999. The input circuit has been optimized for the characteristics of the resistance ruler (potentiometer), resulting in improved display and measurement stability, as well as enhanced resistance to electromagnetic interference and series mode interference. 0.05 level accuracy, measurement and control speed can be set between 5-200 times per second, display range -99999 to 99999. Panel buttons and switch input setting function. Welcome to consult with all users.

Displacement, counting, and angle display control instrumentsBasic specifications

project

specification

power supply voltage

ACpower supply

100~240 V AC 50/60 Hz

AC/DCpower supply

10~24V AC 50/60 Hz10~24V DC

power consumption

ACpower supply

7 VAbelow

AC/DCpower supply

AC6 VAfollowing;DC5Wbelow

Allowable voltage variation range

The voltage of the power supply90%~110%

insulation resistance

100500V DC MEGABenchmark)

insulation strength

2000V AC (Test conditions:50/60Hz1Minutes)

anti-interference

IEC61000-4-2(Electrostatic discharge))Grade III

IEC61000-4-4(Electric Fast Transient Pulse Group), Level III

IEC61000-4-5(Surge), Level III

Protection level

IP65(Product front panel protection)(GB/T42-2008

runtime environment

ambient temperature

-30~60(Save:-40~65

ambient humidity

35~85 %RHNo condensation

Installation location

Indoor, height<2000m

















XSAEW-AHWT1A0 input specifications

project

specification

Measure and control speed

5/20/60/100/200time/Available in seconds

basic error

The measurement and control speed is5time/In seconds, the error is less than ±0.05 %FS

The faster the measurement and control speed, the greater the error

display range

-99999~99999, resolution1/10000

Display specifications

6bitLEDdisplay

Analog input signal type

project

measurement range

potentiometer

W

Range of resistance specifications0.5~100kΩ is acceptable








XSAEW-AHWT1A0 optional specifications

project

specification

alarm

output

160×80size

T1~T4

1~4The output of the alarm relay is normally open+Normally closed dual contacts

250V AC/3A

resistive load

96×48size

T1~T2

1~2The output of the alarm relay is normally open+Normally closed dual contacts

T3

3The output of the alarm relay is a single normally open contact

enter

K1

1Click to enter

(Select)K1At that time, communication and transmission can only choose one


Analog output

A1

current output(4~20)mAThe(0~10)mAThe(0~20)mA

Optoelectronic isolation, resolution:1/3000Load capacity:600Ω

A2

voltage output(0~5)VThe(1~5)V

A3

Voltage output(0-10V

communication

interface

S1

RS232interface

Photoelectric isolation,

Response time: less than500μS(Measurement value)

Communication protocol selected through software
TCASCIIorModbus-RTU

S2

RS485interface

power supply

specification

V0

100~240V AC50/60Hz