- Phone
-
Address
Building 3, Jibang Technology Park, No. 8 Jishan New Road Street, Tianhe District, Guangzhou City
Guangzhou Dongyi Automation Technology Co., Ltd
Building 3, Jibang Technology Park, No. 8 Jishan New Road Street, Tianhe District, Guangzhou City
Displacement/Counting/Angle Display ControllerConnect resistance gauges, eddy current displacement sensors, etc. 0.2 level accuracy, measurement and control speed of 10 times per second. Display range -1999 to 9999. Panel buttons and switch input zero function. There are two panel forms to choose from: basic type and functional type. 8-segment line correction function. Optional 1-4 point alarm output. This includes five basic alarm modes: upper limit of measurement value, lower limit of measurement value, upper limit of deviation, lower limit of deviation, and absolute value of deviation, as well as five standby alarm modes corresponding to the five basic alarm modes. Welcome to consult with all users.
Displacement/Counting/Angle Display Controllerdetailed introduction
Connect resistance gauges, eddy current displacement sensors, etc.
0.2 level accuracy, measurement and control speed of 10 times per second. Display range -1999 to 9999.
Panel buttons and switch input zero function.
There are two panel forms to choose from: basic type and functional type.
8-segment line correction function.
Optional 1-4 point alarm output. This includes five basic alarm modes: upper limit of measurement value, lower limit of measurement value, upper limit of deviation, lower limit of deviation, and absolute value of deviation, as well as five standby alarm modes corresponding to the five basic alarm modes.
(Standby alarm mode: Refers to the situation where the instrument does not alarm even when it is in the alarm zone when powered on. When the measured value enters the non alarm zone, a standby condition is established and normal alarm is triggered thereafter.).
4 optional external power sources.
Optional communication, transmission, and printing functions.
1 Basic specifications
power supply voltage |
ACpower supply |
100-240 V AC 50/60 Hz |
|
AC/DCpower supply |
10-24V AC 50/60 Hz;10-24V DC |
||
power consumption |
ACpower supply |
7 VAbelow |
|
AC/DCpower supply |
AC:6 VAfollowing;DC:5Wbelow |
||
Allowable voltage variation range |
The voltage of the power supply90 ~ 110% |
||
insulation resistance |
100MAbove Ω(500 V DC MEGABenchmark) |
||
Withstand Voltage |
in2000 V AC 50/60Hzdown1minute |
||
anti-interference |
IEC61000-4-2(Electrostatic discharge))Grade III; IEC61000-4-4(Electric Fast Transient Pulse Group), Level III; IEC61000-4-5(Surge), Level III |
||
Protection level |
IP65(Front part of the product) |
||
surrounding environment |
temperature |
-10 ~ 55℃; 保存 -25~ 65℃ |
|
humidity |
35 ~ 85 %RH; Save35 ~ 85 %RH |
||
2 Input specifications
Measure and control speed |
10time/second |
||
basic error |
±0.2 %F.S |
||
display range |
-1999~ 9999 |
||
input signal |
current |
I |
4-20mAThe0-10 mAThe0-20 mA |
voltage |
V |
0-5V DCThe1-5V DC |
|
potentiometer |
W |
500Ω~10KΩ |
|
digital filtering |
Inertia; Average value; moving average wait |
||
3Select accessory specifications
Contact input |
K |
1Click on external input to reset to zero |
|
Contact output |
T1-T4 |
1-4Point,250VAC/3Aresistive load |
|
Analog output (resolution)1/3000) |
A1 |
current output4~20mAThe0~10mAThe0~20mA |
|
A2 |
voltage output0~5VThe1~5V |
||
A3 |
voltage output0~10V |
||
communication interface |
S1 |
TC ASCIIagreementRS232 |
Speed:2400;4800;9600;19200 Address:0 – 99 Response time:500MS(Measurement value) |
S2 |
TC ASCIIagreementRS485 |
||
M1 |
Modbus-RTUagreementRS232 |
||
M2 |
Modbus-RTUagreementRS485 |
||
Printing interface |
P |
Hardware clock |
|
external power supply |
B1 |
24V±5%,50mAbelow |
|
B1G |
24V±5%,100mAbelow |
||
B2 |
12±5%,50mAbelow |
||
B2G |
12±5%,100mAbelow |
||