Product Introduction
Digital buried depth measuring instrumentUsed to measure the buried depth of an empty tank. Use a dial gauge to measure the buried depth of an empty can lid and determine the buried depth dimension. The buried depth gauge is widely used in canning factories, breweries, and beverage factories.
Technical specifications
Measurement range: 0-10mm
Resolution: 0.01mm 0.001mm
Accuracy: 0.03mm 0.005mm

Measurement base material: metal
Measuring rod diameter: ≤φ 1.5mm
Power supply: 1.5V or 3V button battery (different specifications for different meter heads)
Working conditions:
Temperature: 0 ° C~+40C
Relative humidity:<80%
Storage and transportation temperature: -10 ° C~+60 ° C
Usage:
1. Place the instrument on the calibration platform and zero it.
2. Place the sample to be tested horizontally, hold the gauge in hand, and let the measuring needle probe into the bottom of the buried head. After the value stabilizes, read the absolute value of the dial gauge (because the negative value displayed on the gauge is due to the compression zeroing method used, the measured gauge value will be negative, and the negative sign only represents the direction of entry and exit from zero. When taking the value, take its absolute value), which is the buried depth value.

3. Remove the empty can upwards.
Precautions for instrument use:
1. The product is equipped with high-precision sensors and information processing circuits, and must not be soaked.
2. It is strictly prohibited to disassemble the circuit board or adjust the calibration data by oneself.
After turning on the power of the product, if the LCD screen does not display any numbers, the battery should be replaced in a timely manner.
If there is oil stains on the surface, please wipe it clean with a clean and soft cotton cloth.
5. It is not allowed to apply voltage on digital measuring tools, and it is not advisable to use an electric pen to engrave characters to avoid damaging the circuit.

Battery replacement method:
There is a battery mounting position on the side of the watch body. Gently pull the battery cover outward to remove and replace the battery, paying attention to the orientation of the positive and negative poles of the battery, and then insert the battery cover.
Digital buried depth measuring instrumentComes with accessories: instrument box, test probe, spare battery, instruction manual, certificate of conformity, warranty card, and a wiping cloth.