Digital Display Controller XMT-H82-08-000A: XMT-H8 Digital Controller, XMT-S8 Digital Controller, XMT-F9 Digital Controller, XMT-H4 Digital Controller, XMT-S4 Digital Controller
The XMT-H82-08-000A digital display controller uses a good microcontroller as the central processing unit to process input signals, display, keyboard operations, etc. The high-resolution A/D converter enables the instrument to have high measurement accuracy. The input method is flexible, with the option to choose between single input or universal input. Universal input, using jumper free technology, only requires keyboard settings to change the instrument from one input signal to another. The input display range, transmission output range, and alarm control mode can be freely set. The instrument also has RS485 communication function, which can easily form a control system. This series of instruments is suitable for various industrial process control fields, and can measure, display, and control various engineering physical quantities such as temperature, pressure, flow rate, and liquid level.
Model:XMT-H8 (horizontal), XMT-S8 (vertical), XMT-F9 (square), XMT-H4 (horizontal), XMT-S4 (vertical)
Selection:
type number |
generation code |
say bright |
|||||||
XMT- |
□ |
□ |
□ |
□□ |
□ |
□ |
□ |
□ |
Digital display controller |
appearance characteristics |
H |
horizontal format |
|||||||
S |
vertical form |
||||||||
F |
square |
||||||||
Overall dimensions |
4 |
48*96,96*48 |
|||||||
8 |
80*160,160*80 |
||||||||
9 |
96*96 |
||||||||
Control function |
1 |
A set of relays |
|||||||
2 |
Two sets of relays |
||||||||
3 |
Three sets of relays |
||||||||
4 |
Four sets of relays |
||||||||
Type of input |
□□ |
see“Input Type Table” |
|||||||
communication function |
0 |
Nothing |
|||||||
1 |
RS485communication |
||||||||
transmitter output |
0 |
Nothing |
|||||||
1 |
transmitter output |
||||||||
2 |
4-20mAtransmitter output |
||||||||
24VTributary output |
0 |
Nothing |
|||||||
1 |
have |
||||||||
power supply |
A |
AC220Vpower supply |
|||||||
P |
DC24Vpower supply |
||||||||
Example: XMT-H82-16-000A
Note: 1. XMT - □□ - □□ -1 1/2 □□□ (i.e. communication and transmission output functions cannot be simultaneously available)
2. In this series of instruments, the 96mm × 48mm (mode) size instrument cannot be selected.
3. 48mm × 96mm and 96mm × 48mm size instruments can only choose one of the three functions: transmission output, DC 24V output, and communication function; The input type is not
Can choose universal input (input code is 00)
Input type table:
code |
input type |
measurement range |
code |
input type |
measurement range |
code |
input type |
measurement range |
00 |
Universal input |
You can set the input type by yourself |
10 |
Pt100.0 |
-99.9~200.0° C |
20 |
0~5V |
-1999~9999d |
01 |
K |
0~1300° C |
11 |
Cu100 |
-50.0~150.0° C |
21 |
1-5V square root |
-1999~9999d |
02 |
E |
0~1000° C |
12 |
Cu50 |
-50.0~150.0° C |
22 |
0-5V square root |
-1999~9999d |
03 |
J |
0~1000° C |
13 |
0~10mA |
-1999~9999d |
23 |
0~20mV |
-1999~9999d |
04 |
T |
0~400° C |
14 |
0-100mA square root |
-1999~9999d |
24 |
0~50mV |
-1999~9999d |
05 |
B |
500~1800° C |
15 |
0~20mA |
-1999~9999d |
25 |
0~100mV |
-1999~9999d |
06 |
S |
0~1600° C |
16 |
4~20mA |
-1999~9999d |
26 |
0~20mV |
-1999~9999d |
07 |
R |
0~1800° C |
17 |
4-20mA square meter |
-1999~9999d |
|
|
|
08 |
Pt100 |
-200~600° C |
18 |
4-20mA power distribution |
-1999~9999d |
|
|
|
09 |
30~350Ω |
-1999~9999d |
19 |
1~5V |
-1999~9999d |
|
|
|
Note: The universal input (00) can set the input type (P1) code as: 01-12, 15, 16, 18, 19, 20
Main functions and technical indicators of instruments
1. Input methods: various thermocouples, thermistors, current, voltage inputs, and universal inputs. Universal inputs can be changed freely through the keyboard.
2. Input signal: Thermocouples: R, B, S, K, E, J, T
Thermal resistance: PT100, PT100.0, Cu50, Cu100 (lead resistance ≤ 5 Ω) Remote transmission pressure resistance 30-350 Ω
Current: 0-10mA, 4-20mA, 0-20mA
电压: 0~. 、1~. 、0~20mV、0~50mV、0~100mV、0~200mV
3. Output signal
a. Transmission output: 1~ Alternatively, 4-20mA (load resistance ≤ 600 Ω) can be selected.
b. DC 24V output optional, load ≤ 30mA
C. Alarm or control output: 1 to 4 sets of relay outputs are optional, with capacity /3A,./6A, The alarm mode (lower limit, lower limit, upper limit) can be freely set through the keyboard.
4. Measurement accuracy: ± 0.2% ± 1 word
5. Display mode: -1999~9999 words measurement value display 0.56 inches or 0.8 inches high brightness LED digital display LED working status display
6. Parameter setting: The panel has a touch sensitive key for numerical setting. The parameter setting value is saved after power failure, and the display range and transmission output range can be freely set through the keyboard.
7. Temperature compensation: 0-50 ° C digital automatic temperature compensation
8. Communication method: RS485 mode, (communication can be omitted)
9. Power supply: Or optional
10. Power consumption: ≤ 5W
11. Installation method: disk mounted
Similar products: XMZ-H8 digital display instrument (horizontal), XMZ-S8 digital display instrument (vertical), XMZ-F9 digital display instrument (square), XMZ-H4 digital display instrument (horizontal), XMZ-S4 digital display instrument (vertical), XMZG light column display instrument: XMZG-H8 light column display instrument (horizontal), XMZG-S8 light column display instrument (vertical), XMZG-S4 light column display instrument (vertical)