Welcome Customer !

Membership

Help

Tingyi (Shanghai) Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Tingyi (Shanghai) Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 301, Building G, No. 525 Zhangwengmiao Road, Fengxian District, Shanghai

Contact Now

Diffuse silicon pressure transmitter LED-800

NegotiableUpdate on 05/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The diffusion silicon pressure transmitter LED-800 consists of a signal conversion module, and the core component of the sensor is a single crystal silicon wafer. When the single crystal silicon is subjected to pressure, its resistivity changes. Four resistors are diffused on a silicon wafer through semiconductor planar technology and connected to form a Stone bridge. Under constant current, a voltage signal proportional to the pressure signal can be output. The signal conversion module processes and converts the voltage signal of the sensor into a 4-20mA standard signal

Product Details

purpose

Diffuse silicon pressure transmitter LED-800It can be used to measure parameters such as pressure and liquid level of fluids (liquids, gases, and vapors), and convert the measured signal into a 4-20mA standard electrical signal output, which can be used as an input signal for indication, recording, and regulation.Diffuse silicon pressure transmitter LED-800It has the advantages of small size, light weight, high accuracy, and low price. It can be equipped with on-site indicator meters, zero point migration, range expansion and other functions. It can be intrinsically safe and explosion-proof, and has all the functions of industrial pressure transmitters.



Main technical indicators
Working power supply: 12~36V DC
Target audience: liquids, gases, and vapors
Range: 0-250Pa to 100MPa
Output: 4-20mA DC
power supply
Working power supply: 12-36V DC
Output indication
Indication accuracy: ± 2%
Migration: The transmitter can perform a positive zero shift of 50% of the calibration range, but the upper limit of the calibration range must not exceed the upper range limit. Negative transfer is not allowed.
Overvoltage: 2 times the range limit (except for range 7:0-50MPa which is 1.5 times)
temperature range
Working temperature range: -25~C~-80~C
Storage temperature range: -40~C~-120~C
Humidity range: 0-100% relative humidity
Start time: 2 seconds, no preheating required
Accuracy: ± 0.2% of the measuring range, including linearity, variation, and weight.
Temperature effect: The zero position temperature error is 0.75%/55~C of the large range
The comprehensive temperature error is 1.1%/55~C of a large range
Vibration effect: In any direction, the vibration error caused by the vibration frequency up to 200Hz is 0.25%/g of the large measurement range.
Time response: less than 0.2 seconds
Isolation membrane: 316SST
Sensor housing: 1Cr18Ni9Ti
Filling fluid: Silicone oil
Process connection port: optional according to selection information
Electrical connection: The connection holes of the electronic box are 1/2-14NPT taper tube screw holes, and the electrical connection terminal block is located on the terminal side of the electronic box.
Weight: Approximately 1kg