Application Description of Differential Pressure Transmitter LED-1151DP
Differential pressure transmitters are mainly used to measure the differential pressure, pressure, liquid level, and density of liquids, gases, or vapors, and then convert them into 4-20mA.DC signal outputs.
Differential pressure transmitters include three types: DP type (base type), HP type (high static pressure), and DR type (micro differential pressure). The above three types of transmitters can be combined with an intelligent amplifier board to form an intelligent differential pressure transmitter, which can communicate with each other through a handheld device that complies with the HART protocol for setting and monitoring.
The HP type high static pressure differential pressure transmitter is a type of differential pressure transmitter suitable for high-pressure equipment in petrochemical and power plants. Due to its high pressure resistance of up to 32MPa and the ability to withstand unidirectional overload pressure without damage, it can be reliably used for differential pressure measurement in high-pressure systems.
The DR type differential pressure transmitter can convert small differential pressures into 4-20mA DC signals. It uses a specially designed amplification circuit board and a special temperature compensation process, ensuring stable and reliable performance. It is an ideal product for detecting micro pressure, primary and secondary air flow, and airflow loss in furnace combustion chambers.
Differential pressure transmitter LED-1151DP
| Transmitter selection code | ||||||||||||||||||
| Measurement type | DP | Differential pressure transmitter | ||||||||||||||||
| Measurement range (KPa) | 3 | 0 –1.3~7.5 | Note that the use of ranges below 1kPa must be specified in the purchase contract. | |||||||||||||||
| 4 | 0 - 6.2~37.4 | |||||||||||||||||
| 5 | 0 - 31.1~186.8 | |||||||||||||||||
| 6 | 0 - 117~689.5 | |||||||||||||||||
| 7 | 0 - 345~2068 | |||||||||||||||||
| 8 | 0 - 1170~6895 | |||||||||||||||||
| Output signal type | E | 4-20mA.DC analog amplifier, linear output | ||||||||||||||||
| SF | 4-20mA.DC digital amplifier with square root output and 4 1/2 digit digital display | |||||||||||||||||
| S | 4-20mA.DC intelligent amplifier, can choose square root or linear, and uses HART protocol communication | |||||||||||||||||
| structural material |
Container and connector | Exhaust/Drain Valve |
||||||||||||||||
| 1 | chrome-plated carbon steel | 316 steel | ||||||||||||||||
| 2 | 316 steel | 316 steel | ||||||||||||||||
| 3 | Hastelloy C | Hastelloy C | ||||||||||||||||
| 4 | Monel alloy | Monel alloy | ||||||||||||||||
| Isolation diaphragm |
2 | 316 steel select |
||||||||||||||||
| 3 | Hastelloy C | |||||||||||||||||
| 4 | Monel alloy | |||||||||||||||||
| 5 | Tantalum | |||||||||||||||||
| Allowable static pressure value |
B | 5 | ||||||||||||||||
| C | 10 | |||||||||||||||||
| D | 14 | |||||||||||||||||
| Type of filling fluid |
Nothing | low viscosity silicone oil | ||||||||||||||||
| F | Fluorine oil (inert liquid, used in oxygen production system) | |||||||||||||||||
| display mode | M1 | Linear indicator with 0-100% scale |
||||||||||||||||
| M2 | Square root indicator scale 0-10 | |||||||||||||||||
| M4 | Digital display indicator with 0-100% scale | |||||||||||||||||
| Bracket form | B1 | Pipe installation bending bracket (installing pipe diameter 60) | ||||||||||||||||
| B2 | Board mounted bending bracket | |||||||||||||||||
| B3 | Pipe installation bending bracket (installing pipe diameter 60) | |||||||||||||||||
| Location of exhaust/drain valve | D1 | The exhaust/drain valve is installed on the upper part of the side of the chamber | ||||||||||||||||
| D2 | The exhaust/drain valve is installed at the lower part of the side of the chamber | |||||||||||||||||
| flameproof type | d | Explosion proof type, explosion-proof mark Exd Ⅱ BT4-6 |
||||||||||||||||
| LED-1151 | DP | 4 | E | 2 | 4 | C | F | M4 | B2 | Example of Selection from 0 to 35KPa | ||||||||