Welcome Customer !

Membership

Help

Shanghai Jinggong Industrial Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Jinggong Industrial Co., Ltd

  • E-mail

  • Phone

  • Address

    108 Xinjian Village, Lingang New Area, Shanghai Pilot Free Trade Zone

Contact Now

Delger detection tube

NegotiableUpdate on 06/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

German Delger * detection tube 8101041, with a range of 0.1-3 ppm and a specification of 1 box of 10 tubes. This detection tube can detect the * content in air or technical gases. Shanghai Jinggong is a 14 year agent of Delger, with year-round stock and beautiful prices. Welcome to inquire!

Product Details

*It is an inorganic compound with the chemical formula H2O2. Pure * is a light blue viscous liquid that can be mixed with water in any proportion. It is a strong oxidant, commonly known as hydrogen peroxide in aqueous solution, and is a colorless and transparent liquid. Its aqueous solution is suitable for medical wound disinfection, environmental disinfection, and food disinfection. In general, it slowly decomposes into water and oxygen, but the decomposition rate is extremely slow, accelerating its reaction rate.

GermanyDelger detection tube8101041The content of H2O2 in air or technical gases can be measured, with a specification of 1 box of 10 tubes.Delger detection tube priceBeautiful, large quantity is preferred!

<strong>德尔格*检测管</strong> 8.jpg

1.jpg

GermanyDelger detection tube8101041

★ Determine * (H2O2) in air or technical gases.

★ Measurement range: 0.1 to 3 ppm 1 ppm

★ Number of strokes (n): 20 2

★ Measurement duration: approximately 3 minutes. approximately 18 seconds

★ Standard deviation: ± 10-15%

★ Color Change: White → Brown

★ Temperature: 10 ° C to 25 ° C

★ Humidity: 3 to 10 mg/L (equivalent to 50% relative humidity at 23 ° C)

Correction factor: F=1013/actual air pressure (hPa).

2.jpg

2 H2O2 + 2 KI → I2 + 2 H2O + O2

3.jpg

The working principles of the test tube and Dr ä ger gas detection pump are coordinated with each other. Using other pumps may impair the normal function of the test tube.

Please pay attention to the instructions for using the pump (seal test!).

The measurement value is only applicable to the measurement location and measurement time point.

4.jpg

1. Break two tubes in the Dr ä ger tube opener.

2. Insert the test tube tightly into the pump. The arrow points to the pump.

3. Extract air or gas samples through a test tube.

4. Read the color change of the entire length.

5. Multiply the numerical value by the pressure correction factor F.

6. Pay attention to possible cross sensitivity.

7. Rinse the pump with air after use.

1 ppm H2O2 = 1.4 mg H2O2 /m3

1 mg H2O2/m3=0.71 ppm H2O2 (at 20 ° C, 1013 hPa)

5.jpg

GermanyDelger detection tube8101041When simultaneously affected by nitrogen dioxide and chlorine gas, H2O2 cannot be measured. Only display H2O2 vapor, not aerosols.

1693809275687.jpg

<strong>德尔格*检测管</strong> 7.jpg

荣誉.jpg

Shanghai Jinggong has been the agent of Delge for 14 years, with sufficient inventory of gas detectors, compressed air detectors, alcohol detectors, and various protective equipment. Welcome to contact Shanghai Jinggong, the price is beautiful!