Welcome Customer !

Membership

Help

Zhuhai Yiao Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Zhuhai Yiao Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 501-02, Building 1, 1322 Meijie Road, Xiangzhou District, Zhuhai City

Contact Now

DPT146 Dew Point and Pressure Transmitter for Compressed Air

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

DPT146 Dew Point and Pressure Transmitter for Compressed Air $r $n * transmitters that can simultaneously monitor dew point and process pressure $r $n make compressed air monitoring simple. The transmitter $r $n is compatible with the Visa handheld DM70 instrument, enabling convenient sampling, local display, and data recording

Product Details

Basic Description of DPT146 Dew Point and Pressure Transmitter for Compressed Air

  • *A transmitter that can simultaneously monitor dew point and process pressure
  • A transmitter that makes compressed air monitoring simple and user-friendly
  • High precision humidity information can be obtained by utilizing online pressure compensation dew point data
  • Mature sensor technology
  • Compatible with the Visa handheld DM70 instrument, it enables convenient sampling, local display, and data recording
  • Pressure measurement range: 1... 10 bar
  • Dew point measurement range: -60...+30 ° C (-76...+86 ° F), with an accuracy of ± 2 ° C (± 3.6 ° F).

DPT146 Dew Point and Pressure Transmitter for Compressed Air

measured parameter

dew point
pressure
Temperature (when using only RS-485 port output)
Under certain circumstances)
-60 . .. +30 °C (-76 ... +86 °F)
1 . .. 10 bar (14.5 ... 145 psi)
-40 . .. +80 °C (-40 ... +176 °F)

calculation parameters

Calculate ppm moisture value by volume 1 . .. 40 000 ppm
Convert dew point to atmospheric pressure -75 … +30 °C (-103 ... +86 °F)

performance

Dew point accuracy ±2 °C (±3.6 °F)
At a temperature of 23 ° C (73.4 ° F)
Accuracy of pressure in time
Pressure temperature dependence
±0.4 %FS

±0.1 %FS/10 °C(18°F)
temperature accuracy
0 . .. 40 °C (+32 ... +104 °F)
-40...80 °C (-40 ... +176 °F)
PPM accuracy (7 bar)
±0.5 °C (± 0.9 °F)
±1 °C (± 1.8 °F)
± (14 ppm+12% of the reading value)
Sensor response time
Pressure response time
Dew point measurement response time at 20 ° C and 1 bar is 63% [90%]
-50 -> -10 °C Tdf
-10 -> -50 °C Tdf

< 1 s


5 s [ 10 s]
10 s [ 2.5 min]
? ?

working environment

?
Operating temperature of electronic devices
work pressure
relative humidity
-40 … +60 °C (-40 ... +140 °F)
0 … 50 bar (0…725 psi)
0...100 %
?

output

?
Analog output (2 channels)
current output
voltage output
Analog output accuracy
digital output
connector

0 … 20 mA, 4 … 20 mA
0 … 5V, 0 …10V
± 0.01 V / ± 0.01 mA
RS-485, Non isolated, Vaisala protocol
4-pin M8
?

General Information

?
? sensor
working voltage



input current
During the normal measurement process
During the self diagnosis process
External load
Used for current output
Used for voltage output
Shell material
Shell protection level
sensor protection
Storage temperature range
Only transmitter part
transport packaging
mechanical connection
Recommended calibration cycle
Weight (ISO 1/2 ')
Vaisala MPS1 Multi Parameter Sensor
21 . .. 28 VDC, current output
20 . .. 28 VDC, Voltage output and/or use at cold temperatures (-40... -20 ° C (-40... -4 ° F) 15... 28 VDC, RS485 only

20 mA+load current
300 mA+load current

zui大500 Ohm
zui小10 kOhm
AISI316L
IP65(NEMA4)
18 μ m level filter screen AISI303


-40 . .. +80 °C(-40 ... +176 °F)
-20 . .. +80 °C(-4 ... +176 °F)
Mechanical connections ISOG1/2 ", NPT1/2", UNF3/4 "-16
2 years
190 g(6.70 oz)

Compliant with EMC standard EN61326-1, Electrical Equipment for Measurement, Control and Laboratory Use - EMC Specification; industrial environment

For complete parameter information, please refer to the manual or user guide in the "documentation".