DPT145 Dew Point Meter Humidity Density Multi Parameter Transmitter

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

DPT145 sulfur hexafluoride dew point meter humidity density multi parameter transmitter (for SF6 gas) is a transmitter that enables online measurement of seven SF6 parameters in a single device.

Product Details

DPT145 Sulfur Hexafluoride Dew Point Meter Basic Description

  • *A transmitter that enables online measurement of seven SF6 parameters within a single device.
  • Measurement parameters: dew point, pressure, temperature
  • Calculation parameters: SF6 gas density, standardized density (expressed as pressure), dew point and humidity ppm volume ratio under normal pressure
  • From investment and installation to operation and maintenance, comprehensively saving time and money
  • Online measurement can achieve more reliable assessment of SF6 insulation condition
  • A calibration cycle lasting several years

DPT145 Sulfur Hexafluoride Dew Point Meter Parameter Specifications

Technical specifications

measurement parameters

dew point
pressure
temperature
-50 . .. +30 °C (-58 ... +86 °F)
1 . .. 10 bar (14.5 ... 145 psi)
-40 . .. +80 °C (-40 ... +176 °F)

calculation parameters

Standardized to 20 ° C (68 ° F)
Pressure value (density) under the piece

1 . .. 12 bar (14.5…174 psi)
SF6 or SF/N2 mixed density
Ppm moisture value calculated based on volume concentration
Dew point value converted to atmospheric pressure
0...100 kg/m3
40 . .. 40 000 ppm
-65 … +30 °C (-85 ... +86 °F)

performance

Dew point accuracy
Dew point stability
Pressure accuracy at a temperature of 23 ° C (73.4 ° F)
Pressure temperature dependence
± 3 ° C (± 5.4 ° F), refer to the following figure
Five year conventional drift less than 2 ° C (3.6 ° F)
± 0.4% of full range
± 0.1% full range/10 ° C (18 ° F)
Pressure stability
Temperature accuracy
0 . .. 40 °C (+32 ... +104 °F)
-40...80 °C (-40 ... +176 °F)
Five year conventional drift less than 1% of full range

±0.5 °C (± 0.9 °F)
±1 °C (± 1.8 °F)
Density accuracy (high-purity SF6, 1 10 pressure)
0 . .. 40 °C (+32 ... +104 °F)

± 1% of full range
-40 . .. +60 °C (-40 ... +140 °F)
Conventional PPM accuracy (5... 1000 ppm, 7 bar)
± 2.2% full range
± (7 ppm+15% reading)
Sensor response time:
Pressure response time
Dew point response time at a temperature of 20 ° C and a pressure of 1 bar*
63% [90%]
-50 -> -10 °C Tdf
-10 -> -50 °C Tdf

< 1 s


5 s [ 10 s]
10 s [ 2.5 min]
? The response time related to system balance is usually longer. ?
? ?

working environment

?
Operating temperature of electronic devices
work pressure
relative humidity
Tested gas
-40 … +60 °C (-40 ... +140 °F)
0 … 50 bar (0…725 psi)
0...100 %
SF6, SF6/N2 mixed gas
?

output

?
digital output
connector
RS-485, Non isolated, Vaisala protocol
4-pin M8 type
?

General parameters

?
? sensor
working voltage
Sensor Vaisala MPS1 Multi Parameter Sensor
15 . .. 28 VDC
? At cold temperatures (-40... -20 ° C (-40... -4 ° F)), it is 20 .. 28 VDC
? Power supply current during normal measurement process
During the self diagnosis process
Shell material
Shell protection level
?20 mA
Maximum pulse current of 300 mA
AISI316L
IP65 (NEMA4)
? Continuous outdoor use requires the use of an outdoor protective cover
? Storage temperature range
Only applicable to transmitters
transport packaging
mechanical interface
?
-40 … +80 °C (-40 ... +176 °F)
-20 … +80 °C (-4 ... +176 °F)
DILO DN20,ABB Malmkvis, 或
Alstom G1/2 "compatible connector
All interfaces have undergone helium leak detection in the factory
Size chart
Weight (including DILO connector)
Refer to document B211165EN-A
765 grams (27.0 ounces)
Compliant with EMC standard EN61326-1, Electronic Measurement Equipment for Control and Laboratory Use - EMC Requirements
Industrial environment, testing level
EN/IEC 61000-4-2, Electrostatic Discharge
EN/IEC 61000-4-3, Radio frequency field anti-interference capability
EN/IEC 61000-4-4, Electric fast transient
EN/IEC 61000-4-5, surge

EN/IEC 61000-4-6, Inductive RF anti-interference capability

mechanical vibration
EN/IEC 60068-2-6, Fc positive
String vibration

8kV conductor/15kV air
10V/m (80MHz-4.2GHz)
± 2kV power supply and signal
± 2kV power line ground/± 1k line-
Ground and power lines - lines
10Vemf power line, digital
output

± 6 g per axis, 5-500 Hz
Scan for 60 minutes, 3-axis
For complete parameter information, please refer to the manual or user guide in the "documentation".