measurement parameters |
| |
dew point pressure temperature |
-50 . .. +30 °C (-58 ... +86 °F) 1 . .. 10 bar (14.5 ... 145 psi) -40 . .. +80 °C (-40 ... +176 °F) |
| |
calculation parameters |
|
| |
Standardized to 20 ° C (68 ° F) Pressure value (density) under the piece |
1 . .. 12 bar (14.5…174 psi) |
| |
SF6 or SF/N2 mixed density Ppm moisture value calculated based on volume concentration Dew point value converted to atmospheric pressure |
0...100 kg/m3 40 . .. 40 000 ppm -65 … +30 °C (-85 ... +86 °F) |
| |
performance |
|
| |
Dew point accuracy Dew point stability Pressure accuracy at a temperature of 23 ° C (73.4 ° F) Pressure temperature dependence |
± 3 ° C (± 5.4 ° F), refer to the following figure Five year conventional drift less than 2 ° C (3.6 ° F) ± 0.4% of full range ± 0.1% full range/10 ° C (18 ° F) |
| |
Pressure stability Temperature accuracy 0 . .. 40 °C (+32 ... +104 °F) -40...80 °C (-40 ... +176 °F) |
Five year conventional drift less than 1% of full range
±0.5 °C (± 0.9 °F) ±1 °C (± 1.8 °F) |
| |
Density accuracy (high-purity SF6, 1 10 pressure) 0 . .. 40 °C (+32 ... +104 °F) |
± 1% of full range |
| |
-40 . .. +60 °C (-40 ... +140 °F) Conventional PPM accuracy (5... 1000 ppm, 7 bar) |
± 2.2% full range ± (7 ppm+15% reading) |
| |
Sensor response time: Pressure response time Dew point response time at a temperature of 20 ° C and a pressure of 1 bar* 63% [90%] -50 -> -10 °C Tdf -10 -> -50 °C Tdf |
< 1 s
5 s [ 10 s] 10 s [ 2.5 min] |
| ? |
The response time related to system balance is usually longer. |
? |
| ? |
?working environment
|
? |
| |
Operating temperature of electronic devices work pressure relative humidity Tested gas |
-40 … +60 °C (-40 ... +140 °F) 0 … 50 bar (0…725 psi) 0...100 % SF6, SF6/N2 mixed gas |
| ? |
output |
? |
| |
digital output connector |
RS-485, Non isolated, Vaisala protocol 4-pin M8 type |
| ? |
General parameters |
? |
| ? |
sensor working voltage |
Sensor Vaisala MPS1 Multi Parameter Sensor 15 . .. 28 VDC |
| ? |
At cold temperatures (-40... -20 ° C (-40... -4 ° F)), it is 20 .. 28 VDC |
| ? |
Power supply current during normal measurement process During the self diagnosis process Shell material Shell protection level |
?20 mA Maximum pulse current of 300 mA AISI316L IP65 (NEMA4) |
| ? |
Continuous outdoor use requires the use of an outdoor protective cover |
| ? |
Storage temperature range Only applicable to transmitters transport packaging mechanical interface |
? -40 … +80 °C (-40 ... +176 °F) -20 … +80 °C (-4 ... +176 °F) DILO DN20,ABB Malmkvis, 或 Alstom G1/2 "compatible connector |
| |
All interfaces have undergone helium leak detection in the factory |
| |
Size chart Weight (including DILO connector) |
Refer to document B211165EN-A 765 grams (27.0 ounces) |
| |
Compliant with EMC standard EN61326-1, Electronic Measurement Equipment for Control and Laboratory Use - EMC Requirements |
| |
Industrial environment, testing level EN/IEC 61000-4-2, Electrostatic Discharge EN/IEC 61000-4-3, Radio frequency field anti-interference capability EN/IEC 61000-4-4, Electric fast transient EN/IEC 61000-4-5, surge
EN/IEC 61000-4-6, Inductive RF anti-interference capability
mechanical vibration EN/IEC 60068-2-6, Fc positive String vibration |
8kV conductor/15kV air 10V/m (80MHz-4.2GHz) ± 2kV power supply and signal ± 2kV power line ground/± 1k line- Ground and power lines - lines 10Vemf power line, digital output
± 6 g per axis, 5-500 Hz Scan for 60 minutes, 3-axis |
| |