DL vertical condensate lift pump

NegotiableUpdate on 11/10
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The DL vertical condensate lift pump adopts the hydraulic model of the highly efficient and energy-saving product IS pump recommended by the country, and is a vertical multi-stage and multi-stage structure. The screw clamps and connects the inlet section, middle section, and outlet section into one. Each stage of the water pump is equipped with an impeller and a guide vane. The axial force is solved by hydraulic balance method, and the residual axial force is borne by the ball bearing and lubricated with grease. The shaft seal adopts soft packing or mechanical seal. The product complies with the JB/T2727-93 "Types and Basic Parameters of Vertical Multistage Centrifugal Pumps" standard, mainly used for suction and delivery of diluted, clean, non corrosive, non explosive clean water and liquids with physical and chemical properties similar to water that do not contain solid particles or fibers.

Product Details

Scope of application:

This type of condensate pump is widely used for fire protection, domestic water supply, air conditioning unit circulation, and cooling water transportation in high-rise buildings.

Product Features:

  • Advanced hydraulic model: high efficiency and wide performance range.
  • Novel structure and reliable operation: The balance drum has been eliminated, and its axial force adopts hydraulic balance, completely solving the problems of corrosion, biting and wear of the balance drum, ensuring more reliable operation.
  • Less operating and maintenance costs: using high-quality mechanical seals, wear-resistant, leak free, long service life, low failure rate, with less operating and maintenance costs.
  • Smooth operation and low noise: Using a low-speed motor, the pump runs smoothly with lower noise.
  • Vertical structure, small footprint.

Technical Specifications:

  • Flow rate: 4.2-504m3/h;
  • Lift: 24-240m;
  • Power: 1.5-450kw;
  • Speed: 1480r/min;
  • Caliber: φ 40- φ 250;
  • Temperature range: 0-+90 ℃;
  • Work pressure: ≤ 2.4Mpa.

Model meaning:

  • 150 DL(R) 150 - 30×3
  • 150- Pump inlet and outlet diameter (mm)
  • DL - Vertical multi-stage centrifugal pump
  • R - Hot water type
  • 150- Pump design flow rate (m3/h)
  • 30- Pump design point single-stage head (m)3/h)
  • 3- Level
model series Traffic (m)3/h) Flow rate (L/S) Head (m) Speed (r Shaft power (kw) Motor power (kw) Efficiency (%) Suction distance (m) Cavitation allowance (m)
40DL 2 6.2 1.72 23.6 1450 0.92 1.5 40 7 3.19
3 6.2 1.72 35.4 1.38 2.2 40 7 3.19
4 6.2 1.72 47.2 1.84 3 40 7 3.19
5 6.2 1.72 59 2.30 4 40 7 3.19
6 6.2 1.72 70.8 2.75 4 40 7 3.19
7 6.2 1.72 82.6 3.22 5.5 40 7 3.19
8 6.2 1.72 94.4 3.68 5.5 40 7 3.19
9 6.2 1.72 106.2 4.14 7.5 40 7 3.19
10 6.2 1.72 118 4.60 7.5 40 7 3.19
11 6.2 1.72 129.8 5.06 7.5 40 7 3.19
12 6.2 1.72 141.6 5.52 11 40 7 3.19
50DL 2 12.6 3.5 24.4 1450 1.55 3 54 7.6 2.66
3 12.6 3.5 36.6 2.33 3 54 7.6 2.66
4 12.6 3.5 48.8 3.10 4 54 7.6 2.66
5 12.6 3.5 61 3.88 5.5 54 7.6 2.66
6 12.6 3.5 73.2 4.65 5.5 54 7.6 2.66
7 12.6 3.5 85.4 5.43 7.5 54 7.6 2.66
8 12.6 3.5 97.6 6.20 7.5 54 7.6 2.66
9 12.6 3.5 109.8 6.98 11 54 7.6 2.66
10 12.6 3.5 122 7.75 11 54 7.6 2.66
65DL 2 30 8.33 32 1450 4.22 5.5 62 7.6 2.82
3 30 8.33 48 6.33 7.5 62 7.6 2.82
4 30 8.33 64 8.44 11 62 7.6 2.82
5 30 8.33 80 10.55 15 62 7.6 2.82
6 30 8.33 96 12.66 15 62 7.6 2.82
7 30 8.33 112 14.77 18.5 62 7.6 2.82
8 30 8.33 128 16.88 22 62 7.6 2.82
9 30 8.33 144 18.99 22 62 7.6 2.82
10 30 8.33 160 21.1 30 62 7.6 2.82
80DL 2 50.4 14 40 1450 7.84 11 70 7.8 22.49
3 50.4 14 60 11.76 15 70 7.8 2.49
4 50.4 14 80 15.68 22 70 7.8 2.49
5 50.4 14 100 19.60 30 70 7.8 2.49
6 50.4 14 120 23.52 30 70 7.8 2.49
7 50.4 14 140 27.44 37 70 7.8 2.49
8 50.4 14 160 31.36 45 70 7.8 2.49
9 50.4 14 180 35.28 45 70 7.8 2.49
10 50.4 14 200 39.20 55 70 7.8 2.49
100DL-72-20 2 72 20 40 1450 10.9 15 72 8 2.8
3 72 20 60 10.9 18.5 72 8 2.8
4 72 20 80 10.9 30 72 8 2.8
5 72 20 100 10.9 37 72 8 2.8
6 72 20 120 10.9 37 72 8 2.8
7 72 20 140 10.9 45 72 8 2.8
8 72 20 160 10.9 55 72 8 2.8
9 72 20 180 10.9 55 72 8 2.8
10 72 20 200 54.4 70 72 8 2.8
100DL-100-20 2 100 27.8 40 1450 15.14 18.5 72 7.2 3.53
3 100 27.8 60 22.72 30 72 7.2 3.53
4 100 27.8 80 30.28 37 72 7.2 3.53
5 100 27.8 100 37.86 45 72 7.2 3.53
6 100 27.8 120 45.39 55 72 7.2 3.53
7 100 27.8 140 53.0 75 72 7.2 3.53
8 100 27.8 160 60.57 75 72 7.2 3.53
9 100 27.8 180 68.14 90 72 7.2 3.53
10 100 27.8 200 75.71 90 72 7.2 3.53
150DL-150-20 2 150 27.8 40 1450 20.42 30 80 5.7 2.8
3 150 27.8 60 30.63 37 80 5.7 2.8
4 150 27.8 80 40.84 45 80 5.7 2.8
5 150 27.8 100 51.05 55 80 5.7 2.8
6 150 27.8 120 61.26 75 80 5.7 2.8
7 150 27.8 140 74.47 75 80 5.7 2.8
8 150 27.8 160 81.68 90 80 5.7 2.8
200DL-280-30 2 280 41.6 60 1450 55.79 90 84 6.0 3.7
3 280 41.6 90 83.69 110 84 6.0 3.7
4 280 41.6 120 111.57 132 84 6.0 3.7
5 280 41.6 150 139.47 160 84 6.0 3.7
6 280 41.6 180 163.38 200 84 6.0 3.7


Outline installation dimension diagram


Outline installation dimension table




Flange installation dimension diagram:


Flange installation dimension table:


fault reason solution
1. The pump does not absorb water, and the pressure gauge pointer swings violently. Insufficient irrigation and water intake, resulting in air leakage at the connection between the pipeline and the instrument. Check if the bottom valve is leaking, fill it with water, tighten or repair the leak.
2. The water pump is not producing water, and the vacuum gauge indicates high vacuum. The bottom valve is not open or blocked, the resistance of the suction pipeline is too high, and the suction height is too high. Check the bottom valve, replace the water pipe, and lower the suction height.
3. The pressure gauge has pressure, but it still does not release water. The resistance of the outlet pipe is too high, the rotation direction is incorrect, the impeller is blocked, and the pump speed is insufficient. Check or shorten the water pipe. Check the motor, remove any dirt from the impeller, and increase the pump speed.
4. The flow rate is lower than the design requirements. The water pump is blocked, the sealing ring is worn too much, and the speed is insufficient. Clean the water pump and pipeline, replace the sealing ring, and increase the pump speed.
5. The pump consumes too much power. The packing gland is too tight and heats up, the impeller is worn, and the pump flow rate increases. Adjust the tightness of the packing gland, check if the pump shaft is bent, replace the impeller, increase the water outlet resistance, and reduce the flow rate.
6. The sound inside the pump is abnormal and the pump is not producing water. Excessive resistance in the suction pipe, air leakage in the suction pipeline, and high temperature of the conveyed liquid. Check the suction pipe and bottom valve, block any leaks, reduce the suction height, and lower the water temperature.
7. The water pump vibrates and the bearings overheat. The motor and pump are not concentric, and the bearings are short of oil or worn. Adjust the coaxiality between the motor shaft and the pump shaft, add oil or replace the bearings.