Welcome Customer !

Membership

Help

Xiangtan Xinlian Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

DHF series spodumene rapid analyzer

NegotiableUpdate on 01/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The DHF series spodumene rapid analyzer is developed based on the principle of photometric analysis, using linear extension and sensitivity improvement methods. Solved the problem of traditional photometric analysis of high component content deviating from linearity and poor sensitivity in analyzing low component content. Realized rapid analysis on a large scale and with high precision. Specially suitable for industries such as ceramics, refractory materials, cement, glass, geology, non-metallic minerals, etc. This product has been promoted and applied in more than 1000 colleges, research institutes, factories, and mining enterprises, all of which have achieved good results and have entered the market in bulk.
Product Details

研发中心 大门 高企.png

05.jpg

DHF series spodumene rapid analyzerIt is an analyzer developed based on the principle of photometric analysis, using linear extension of * and methods to improve sensitivity. Solved the problem of traditional photometric analysis of high component content deviating from linearity and poor sensitivity in analyzing low component content. Realized rapid analysis on a large scale and with high precision. Specially suitable for industries such as ceramics, refractory materials, cement, glass, geology, non-metallic minerals, etc. This product has been promoted and applied in more than 1000 colleges, research institutes, factories, and mining enterprises, all of which have achieved good results and have entered the market in bulk.

DHF series spodumene rapid analyzerAnalysis tolerance explanation:

Analysis error: The analysis error of this equipment is formulated in accordance with the requirements for error in two national standards, GB/T4734 Chemical Analysis Methods for Ceramic Materials and GB/T6900 Chemical Analysis Methods for Refractory Materials. The analysis error of the analyzer should meet or exceed the allowable error specified in the national standard method. The allowable errors for the analysis method standards of the two countries are as follows:

Allowable errors in the analysis of ceramic materialsGB/T4734

Allowable errors in the analysis of refractory materialsGB/T6900

project

Content range(%)

Allowable error(%)

project

Content range(%)

Allowable error(%)

SiO2

≤60

60

0.30

0.40

SiO2

5.00-15.00

15.00-30.00

30.00-65.00

0.20

0.30

0.50

Al2O3

≤20

20

0.30

0.40

Al2O3

30.00-40.00

40.00-60.00

60.00-80.00

80.00

0.50

0.60

0.70

0.80

Fe2O3

≤0.50

0.51-1.0

1.1-2.0

0.05

0.10

0.15

Fe2O3

0.50-1.00

1.00-2.00

2.00-4.00

0.10

0.15

0.20

TiO2

≤0.30

0.31-1.0

1.10

0.05

0.10

0.15

TiO2

0.50-1.00

1.00-2.00

2.00-4.00

0.10

0.15

0.20

CaO(MgO)

≤0.10

0.11-1.0

1.0

0.05

0.10

0.15

CaO

≤0.50

0.50-1.00

0.08

0.10

MgO

0.05-0.10

0.10-0.50

0.50-1.00

1.00-2.00

0.02

0.05

0.10

0.15

K2O(Na2O)

≤1.0

1.1-5.0

5.1-10

10

0.15

0.25

0.35

0.45

K2O(Na2O)

≤0.100

0.10-0.50

0.50-1.00

1.00-2.00

2.00-4.00

0.02

0.06

0.10

0.20

0.30

Burning loss

≤1.0

1.1-5.0

5.0

0.05

0.10

0.15

Burning loss

≤0.50

0.51-1.00

1.10-5.00

5.00-10.00

10.00-15.00

0.10

0.15

0.20

0.30

0.35


03.jpg

04.jpg