I. Overview
DDSY6111 single-phase stepped multi rate prepaid electricity meter is designed and manufactured based on the actual electricity consumption of residents. It has high accuracy and reliability.
This instrument is designed with a dedicated chip for electric energy measurement, combined with mature multi rate and prepaid technologies. It is an instrument product manufactured using 16 bit digital sampling processing technology and SMT process. Improved the reliability and service life of the product, and the data display adopts a large screen LCD for easy meter reading.
This instrument can realize functions such as time-sharing metering prepayment, setting daily meter reading, handheld computer programming, and meter reading; Can be set2A time zone,4Fee rate,12Daily time period; And it has infrared and485Communication function, capable of remote meter reading, communication protocol can supportDL/T 645-2007The Communication Protocol for Multi functional Energy Meters provides essential conditions for the automation management of electricity consumption.
Its performance indicators comply with the technical requirements for electronic active energy meters in GB/T 17215.321-2008 "Static AC Active Energy Meters for Class 1 and Class 2", meet the technical requirements for multi rate energy meters in GB/T15284-2002 "Special Requirements for Multi rate Energy Meters", and comply with various technical requirements of GB/T18460-2001 "IC Card Prepaid Electricity Sales System".
2、 Main functions
Remote prepaid energy meters have the following basic functions:
2.1 Time division active positive and negative energy metering, which can be divided into 4 rates, 12 time periods, and 2 time zones.
2.2 With staircase function, up to 4 staircases can be set, and the electricity quantity and price of each staircase can be set separately.
2.3 Infrared communication, programming settings, and meter reading can be performed through a handheld computer.
2.4 It can achieve parameter rotation display, and the parameters (no more than 32 items) and time intervals of the rotation display can be pre-set. The order of parameter rotation display can also be set arbitrarily.
2.5 Equipped with optocoupler isolation active passive pulse output interface, with the same pulse constant as the meter constant.
2.6 Record the total active power and hourly power for 12 months, and meter reading can be done through infrared or 485 methods.
2.7 It has programming prohibition function and data reset function.
2.8 Support for reduced meter reading according to departmental regulations.
2.9 It has the function of purchasing electricity first and then using it, and automatically freezing the monthly electricity consumption rates on designated meter reading days.
2.10 IC card can be used for parameter setting and meter reading.
2.11 adopts a one meter one card method, with multiple verifications and encryption of data in the IC card, ensuring security and reliability.
2.12 Each time electricity is purchased, data is transmitted bidirectionally through the power card.
2.13 Can set non working hours and emergency credit limits.
2.14 Within the rated current range, the maximum operating power can be limited (by the power supply department).
2.15 has an external alarm output interface.
3.16 has built-in sound and light alarm, trip and power-off functions
a. When overloaded, it is possible to control the output of alarm and trip signals by selecting whether to allow alarm tripping.
b. When the remaining power is less than or equal to the alarm set value, the alarm and trip signals can be controlled by selecting whether the meter is allowed to output alarm and trip signals.
c. When the remaining power is zero, the meter outputs a trip signal.
3.15 has the functions of remote meter reading, remote opening and closing, and remote electricity sales.
3、 Working principle
When the electric energy meter is working, the voltage and current are sampled separately by the sampling circuit, and then multiplied by a dedicated integrated circuit for electric energy processing before being sent to the CPU for processing. Finally, the CPU sends the processed data to output devices such as the display and communication parts as needed.
The information system is managed by a computer, and through an IC card reader/writer, a certain amount of electricity and monitoring requirements are written into the IC card input table of the microprocessor system. After being processed by the CPU, it provides display, alarm, and cut-off status signals.
The working principle of the instrument is shown in Figure 1.
4、 Technical indicators
4.1 Accuracy Level Active 1.0 2.0 Level
4.2 Reference voltage 220V
4.3 Rated current 1.5 (6) A, 2.5 (10), 5 (20) A, 10 (40) A, 15 (60) A, 20 (80) A
4.4 Rated frequency 50Hz
4.5 Starting current level 1: ≤ 0.004In
Level 2: ≤ 0.005In
4.6 Stealth with anti creep logic design
4.7 External dimensions 168mm × 110mm × 61mm
4.8 Weight approximately 1 kg
4.9 Electrical Parameters
|
Operating Voltage |
0.9Un~1.1Un |
|
Extreme working voltage |
0.75Un~1.15Un |
|
Voltage line power consumption |
≤ 2W and 5VA |
|
Power consumption of current circuit |
<1VA |
|
Data backup battery voltage |
3.0VDC |
4.10 Rate Working Parameters
|
Clock accuracy (daily error) |
≤0.5S (23℃) |
|
battery capacity |
≥1000mAh |
|
Data retention time after power outage |
≥ 10 years (using new batteries) |
4.11 Climate conditions
|
Normal operating temperature |
-20℃~+50℃ |
|
working temperature limit |
-30℃~+60℃ |
|
Storage and transportation temperature |
-40℃~+70℃ |
|
Storage and working humidity |
≤85% |
4.12 Technical Parameters
|
rate number |
4 |
|
Number of time periods |
12 |
|
Number of time zones |
2 |
|
Measurement range |
0~999999.99 kWh |
|
display |
Liquid Crystal (LCD) |
|
Baud rate |
RS485:1200bps~9600 bps、 Infrared port: 1200bps |
|
Communication Protocol |
DL/T645-2007 Multifunctional Energy Meter Communication Protocol |
5、 Display symbol description
Full screen display effect image
Please refer to Appendix 3: Functional Appendix Table for specific display items
6、 Electric meter diagram
Physical picture of electric meter
Explanation of indicator lights in the diagram
|
7、 Programming instructions
7.01 Programming allowed. The authorized person opens the programming switch button of the electric energy meter (completed by transmitting signals through an IC card), and the programming symbols are displayed on the LCD screen. The electric energy meter is in the programming state, and at this time, the handheld computer can communicate with the electric energy meter to complete the programming settings.
7.02 Data reset. If the energy meter is in the zeroing allowed state, use the zeroing card to reset all internal electricity data and historical record data of the meter.
7.03 Programming is prohibited. After the programming of the energy meter is completed (through signal transmission via IC card), press the programming switch button once, and the programming symbol on the LCD display screen disappears. At this time, the energy meter is in a programming disabled state, and the internal parameters of the energy meter can only be read out, not modified. Only electricity meters within the specified error range can be calibrated.
Note: In order to prevent unauthorized personnel from operating the programming switch after it is turned on, a 10 minute allowed programming time is specially set in the meter. When the time exceeds, the meter will automatically disable programming.
7.04 Table Number and Factory Number: The identification number for communication between the handheld computer and the energy meter. When reading or setting up meters, it is necessary to input the meter number or factory number of the energy meter in order for the handheld computer to communicate with the energy meter normally. The meter number can also be assigned to the user's account through the purchase of a power card. The factory number is assigned when the electricity meter leaves the factory and printed on the meter nameplate.
7.05 Rotation Time: The display time of each data item during rotation, with a default rotation time of 4 seconds.
7.06 Wheel Display Content Encoding: The encoding of the wheel display content that users can set according to their needs, as detailed in Appendix 3.
7.07 Automatic Meter Reading Date and Time: Programmable Meter Reading Date and Time. If the item is assigned as 28 00, the meter will automatically store the current data in the previous month's records at 0:00 on the 28th of each month. Users can set their content as needed.
7.08 Main and Deputy Time Periods: Two time periods can be set, namely two sets of rates, such as daylight saving time.
7.09 Sub period start and end dates: If set to start date 040503 and stop date 041003.
7.10 Time slot and rate number: The peak rate number is 01; The peak rate number is 02; The flat rate number is 03; The grain rate number is 04.
7.11 Public Holidays: 24 public holidays can be set at a time.
7.12 Weekends off: You can specify a weekend for the middle of each week.
7.13 Non business hours: You can set daily non business hours. For example: 18:00-08:30
7.14 Emergency credit limit: The limit of emergency credit allowed for users during public holidays, weekends, and non business hours can be set. The above management parameters can be transmitted from the management system to the user's electricity meter through preset cards and purchase cards.
7.15 Date: should be the current accurate date.
7.16 Time: should be the current accurate time. The date and time should be regularly checked on-site.
8、 Installation and wiring
8.1 The instrument shall be inspected and sealed with lead before leaving the factory. Before installation and use, it is necessary to check whether the lead seal is intact. If the lead seal is intact, it can be installed and used. For instruments without lead seals or stored for too long, relevant departments should be asked to re inspect them. Only qualified instruments can be installed and used.
8.2 The instrument should be installed in a ventilated and dry indoor area, fixed with three screws, and drilled with holes on the bottom plate according to the installation size shown in Figure 1 (150 × 231). The base should be fixed on a sturdy, fire-resistant, and non vibrating object to ensure safe and reliable installation and use. In places with pollution or potential damage to the instrument, the instrument should be protected by a protective cabinet.
8.3 The instrument should be wired correctly according to the wiring diagram. It is recommended to use copper wire or copper connectors for the incoming wires of the terminal box. The screws inside the terminal box should be tightened to avoid burning due to poor contact or thin leads.
8.4 The instrument will enter normal operation after being powered on according to the correct wiring as described above
8.5 Wiring diagram
Wiring diagram
9、 Transportation and storage
The product should not be subjected to severe impact during transportation and unpacking, and should be transported and stored in accordance with GB/T5464-1995 "General Technical Conditions for Packaging of Instruments and Meters".
Inventory and storage should be stored on racks in their original packaging conditions, with a stacking height not exceeding 5 layers.
The storage location should be clean, with an ambient temperature of 0-40 ℃, a relative humidity not exceeding 85%, and no harmful substances in the air that can cause corrosion.
10、 Guarantee period
From the date of sale, if the user complies with the requirements specified in the manual and the lead seal of the manufacturer is still intact, the company will provide a 2-year warranty for the electric energy meter
Appendix 1 Prepaid Function Description
1、 Normal use
Electric energy meters with prepayment function use IC cards for purchasing and managing electricity. And there are multiple functional cards such as preset card, power purchase card, power check card, reset card, etc. for setting, purchasing, checking, and resetting operations.
New meter installation: When using a meter that has been reset to zero and is functioning properly, the preset card should be used to preset parameters such as load control, main time period, sub time period, meter reading date, and wheel display items.
Clock calibration: It is necessary to use a meter reader for broadcasting time synchronization.
Account opening form: Use the upper computer software "Electricity Sales Management System" to open an account and pay the advance payment for this electricity purchase. Insert the generated user card into the new table, completing the account opening and pairing of one table and one card.
User electricity purchase: The management system settles the actual electricity bills receivable by the user based on the total, peak, average, and valley electricity consumption returned by the user card. And pay the advance payment for this electricity purchase. New load control, sub time periods, meter reading days, public holidays and other parameters are also written into the power purchase card and transmitted to the electricity meter.
For the convenience of real-time operation, this table can also be programmed with a handheld computer or infrared remote control for parameter settings. The content of parameter programming is related to multiple rate parameters. The pre paid part of the setting parameters must be transmitted and set by the preset card and the power purchase card.
2、 Check function
A power card can check one meter. Using a power card can facilitate the electricity management department to check the parameter data of any meter. Important data such as electricity consumption, purchased electricity, remaining electricity, etc. can be written back to the power card. The data content written back by the power card can be read out by the electricity sales management system.
3、 Management function
3.1Load control settings
According to the user type and power supply season, policies for controlling the user's electricity load can be formulated, and different load management can be carried out for peak, off peak, off peak, and off peak periods to achieve the management goal of "peak shaving and valley filling". When running, open the electricity meter and save the data stored in the already opened meter2If the PROM display board is unplugged and replaced with a new meter, the new meter can replace the original meter and all data will be the same as the fault meter. (The nameplate of the electric meter also needs to be replaced with a new one)
(2) When the allowed load and remaining power exceed the pre-set values, and the available power of the meter is zero, the meter will output an alarm or trip signal.
Attention: When both alarm and trip are selected, trip takes priority over alarm.
(3) When the remaining power of the meter is 0 and the external power supply circuit cannot be disconnected due to emergency credit or other reasons, the meter will start calculating the overdrawn power and automatically deduct the overdrawn power when the next power card is inserted.
5、 Instructions for various functional cards
5.1Set card
The setting card is a setting card created by the electricity sales system after the installation of the electricity meter, which sets the basic parameters of the electricity meter in this system. Only the electricity meter that has been set up can be used to open an account and purchase electricity.
5.2Pre installed card
The new watch can be installed directly after leaving the factory. After using the "preset card" to preset the specified "preset power" and multi rate extended data, it can be powered on for use. And transition from factory state to installation state. The preset power consumption is treated as an internal "credit limit" in the electricity meter, which can be automatically deducted when inserting the purchase card. Note: It can also be pre-set by the manufacturer.
Pre installed cards can be used interchangeably to set up meters of the same specifications and can be reused. Used and managed by watch installation personnel.
The installed electricity meter needs to be paired with one meter and one card before accepting the electricity purchase account opening card.
The power of the preset card is written into the electricity sales management system, and the power can be written from 0 to 100 yuan.
Without a pre account electricity meter, multiple pre-set cards can be accepted, with the last pre-set data being valid.
Note: The preset card can also be used for testing and typing tests on the electricity meter. After the test is completed, use the reset card to reset it to zero.
5.3Purchase electricity card
Users bring their purchase cards to the electricity sales department to purchase electricity, and the department uses the electricity sales management system to manage the usage
The amount of electricity purchased by the household is written into the electricity purchase card. The power purchase card adopts a one meter one card method, and the power purchase cards listed by each user are not interchangeable with each other. The power sales management system saves the original records stored by users.
If the hoarding limit is set to the maximum value of 9999 yuan, the maximum amount of electricity purchased by the user at a time is 9999 yuan. When the sum of the purchased electricity and the remaining electricity in the meter is greater than the storage limit, the meter displays "009999.00", and the purchased electricity in the card will not be written into the meter. When the sum of the remaining electricity and the purchased electricity is less than the storage limit, the purchased electricity card will be inserted again, and the purchased electricity will be read in.
After inserting the power purchase card into the meter, wait for the meter to confirm that the user number and password are correct, and then write the purchased electricity into the meter. The power purchase card has the function of writing back the operation data of the electricity meter, such as the current electricity level, remaining amount, meter status, and the electricity level of the previous three months, which are written back to the power purchase card and read out through the electricity sales management system for easy management.
The system can also transmit parameters such as public holiday data, primary and secondary time periods, and load control methods during electricity sales according to actual needs. This function can be selected and set in the electricity sales management system software.
5.4Check the power card
A power card can check one meter. Using a power card can facilitate the electricity management department to check the parameter data of any meter. Important data in the meter, such as energy, purchase amount, remaining amount, etc., can be written back to the power card. The data content written back by the power card can be read out by the electricity sales management system.
Inserting the power card again before the first check shows that it has not ended can detect whether the relay can trip normally.
5.5Clear card
After inspection and testing, the electricity meter can be reset to zero (can be used multiple times) to restore its factory state and put back into use.
Conditions for using the reset card:
(1) Press the programming key to enter programming mode.
(2) Within 2 minutes of the electricity meter being powered on.
5.6Meter reading card
Electric card usage: Used for copying meter data during the manufacturing process and user usage. a
The meter reading card can read up to 100 meters of data. When the number of meter readings exceeds 100, the last collected data will overwrite the data in the 100th meter.
Note: The meter reading card only returns internal data for the prepaid portion.
If you want to collect historical records and other data of multiple rates, you should use a meter reader to collect them.
5.7test card
Usage of electric card: Used for rapid inspection and evaluation of electric meter performance testing, re inspection, and process aging procedures during manufacturing processes and acceptance inspections.
Appendix 2 Explanation of User Precautions
1. One table, one card:
The IC card held by the user cannot be exchanged. In case of loss, a replacement card should be purchased from the power supply department (sales office).
2. Preparation for purchasing electricity:
Before purchasing electricity, users must insert their IC card into the electricity meter once to facilitate the return of data from the meter to the computer database.
3. When purchasing electricity, please declare the amount of electricity to be purchased and the alarm reminder amount.
4. Electricity card usage: Insert the power purchase card into the electricity meter. If it is a valid power purchase card, the electricity meter will automatically read the data into the meter. The LCD display screen will show the total purchased electricity, remaining electricity, overdrawn electricity, purchased electricity, and the number of times the electricity meter has been used. Please store the unplugged card properly.
5. Operation display: During the operation of the electricity meter, it alternately displays the total average electricity, peak and valley electricity, remaining electricity, and operation period in the meter.
6. Overcapacity alarm: During the operation of the electricity meter, if the "alarm" LED indicator flashes rapidly, it warns the user that the electricity has been exceeded. If the meter is set to the over capacity power-off limit mode, after 30 seconds of over capacity power consumption, it will be tripped for 3 minutes and the countdown display (180 seconds) will show the time to restore power supply; The user's card insertion response can immediately restore power supply.
7. Accumulation limit: If the purchased electricity+remaining electricity>accumulation limit (e.g. 9999kWh), the purchased electricity will not be read in, and the display will show a "NNNNNN" prompt, indicating that the electricity in the card is still valid.
8. Warning reminder: When the remaining battery level in the meter is less than twice the "alarm battery level", the "alarm" LED indicator will flash (with an interval of 1 second) to remind the user to purchase electricity. At this time, if the user responds by inserting a card, the "alarm indicator" will flash at an interval of 2 seconds to avoid power outage warnings.
9. Power outage warning: If the user does not respond by inserting the card during the warning reminder, when the remaining power is the alarm power agreed upon by the user (or 10% of the purchased power), the electricity meter will be tripped and a power outage warning will be issued. At this time, inserting the IC card into the electricity meter once will restore power supply. If the IC card of this meter cannot be found after pulling the switch, you can borrow a neighbor's IC card to insert it and restore power supply.
10. Power purchase reminder: When the remaining power in the meter is less than the "alarm power", the "alarm" LED indicator will remain on as a constant reminder.
11. Fault declaration: When the remaining power is displayed as zero or negative, the "alarm" LED indicates. If the meter continues to operate (except for emergency credit), the user should immediately purchase electricity and proactively report the situation to the power supply department.
12. Emergency credit can be granted during non working hours, weekends, and public holidays. When the battery level is zero and the business outlet cannot purchase electricity without going to work, a power purchase card can be inserted to activate emergency credit. Emergency credit for electricity cannot exceed the 'credit limit'.
13. When emergency credit is due, the electricity load is limited, and users should purchase electricity as soon as possible to avoid affecting their daily lives.