E-mail
maike168@126.com
- Phone
-
Address
Jinhui Industrial Park, Fengxian District, Shanghai
Shanghai Maike Pump Manufacturing Co., Ltd
maike168@126.com
Jinhui Industrial Park, Fengxian District, Shanghai
This type of condensate pump is suitable for industrial and urban water supply and drainage, high-rise building pressurized water supply, garden sprinkler irrigation, fire pressurization, long-distance water supply, heating, bathroom and other cold and warm water circulation pressurization and equipment matching, especially suitable for small boiler water supply.
| model | series | Traffic Q | head (m) |
speed (r/min) |
Motor power (KW) |
|
| m3/h | L/S | |||||
| D-50 type | 2 | 18 | 5 | 19 | 2900 | 2.2 |
| 3 | 18 | 5 | 28.5 | 2900 | 3 | |
| 4 | 18 | 5 | 38 | 2900 | 4 | |
| 5 | 18 | 5 | 47.5 | 2900 | 5.5 | |
| 6 | 18 | 5 | 57 | 2900 | 5.5 | |
| 7 | 18 | 5 | 66.5 | 2900 | 7.5 | |
| 8 | 18 | 5 | 76 | 2900 | 7.5 | |
| 9 | 18 | 5 | 85.5 | 2900 | 7.5 | |
| 10 | 18 | 5 | 95 | 2900 | 11 | |
| 11 | 18 | 5 | 104.5 | 2900 | 11 | |
| 12 | 18 | 5 | 114 | 2900 | 11 | |
| D-80 type | 2 | 32.4 | 9 | 22.7 | 2900 | 3 |
| 3 | 32.4 | 9 | 34.05 | 2900 | 5.5 | |
| 4 | 32.4 | 9 | 45.4 | 2900 | 7.5 | |
| 5 | 32.4 | 9 | 56.75 | 2900 | 7.5 | |
| 6 | 32.4 | 9 | 68.1 | 2900 | 11 | |
| 7 | 32.4 | 9 | 79.45 | 2900 | 15 | |
| 8 | 32.4 | 9 | 90.8 | 2900 | 15 | |
| 9 | 32.4 | 9 | 102.15 | 2900 | 15 | |
| 10 | 32.4 | 9 | 113.5 | 2900 | 18.5 | |
| 11 | 32.4 | 9 | 124.85 | 2900 | 18.5 | |
| 12 | 32.4 | 9 | 136.2 | 2900 | 18.5 | |
| D-100 type | 2 | 54 | 15 | 35.4 | 2900 | 11 |
| 3 | 54 | 15 | 52.8 | 2900 | 15 | |
| 4 | 54 | 15 | 70.4 | 2900 | 18.5 | |
| 5 | 54 | 15 | 88 | 2900 | 22 | |
| 6 | 54 | 15 | 105.6 | 2900 | 30 | |
| 7 | 54 | 15 | 123.2 | 2900 | 37 | |
| 8 | 54 | 15 | 140.8 | 2900 | 37 | |
| 9 | 54 | 15 | 158.4 | 2900 | 45 | |
| 10 | 54 | 15 | 176 | 2900 | 45 | |
| 11 | 54 | 15 | 193.6 | 2900 | 55 | |
| 12 | 54 | 15 | 211.2 | 2900 | 55 | |
| D-125 type | 2 | 108 | 30 | 40 | 2900 | 22 |
| 3 | 108 | 30 | 60 | 2900 | 30 | |
| 4 | 108 | 30 | 80 | 2900 | 37 | |
| 5 | 108 | 30 | 100 | 2900 | 45 | |
| 6 | 108 | 30 | 120 | 2900 | 55 | |
| 7 | 108 | 30 | 140 | 2900 | 55 | |
| 8 | 108 | 30 | 160 | 2900 | 75 | |
| 9 | 108 | 30 | 180 | 2900 | 75 | |
| 10 | 108 | 30 | 200 | 2900 | 90 | |
| 11 | 108 | 30 | 220 | 2900 | 90 | |
| 12 | 108 | 30 | 240 | 2900 | 110 | |
| D-150 type | 2 | 162 | 45 | 54.6 | 2900 | 37 |
| 3 | 162 | 45 | 81.9 | 2900 | 55 | |
| 4 | 162 | 45 | 109.2 | 2900 | 75 | |
| 5 | 162 | 45 | 136.5 | 2900 | 90 | |
| 6 | 162 | 45 | 163.8 | 2900 | 110 | |
| 7 | 162 | 45 | 191.1 | 2900 | 132 | |
| 8 | 162 | 45 | 218.4 | 2900 | 160 | |
| 9 | 162 | 45 | 245.7 | 2900 | 160 | |
| model | series | Traffic Q | Head (m) | Speed (r | Power n (kW) | Allow gas Corrosion allowance (m) |
Efficiency (%) | impeller diameter (mm) |
||
| m3/h | (l/s) | shaft power | motor power |
|||||||
| D6-25 DG6-25 DGR6-25 |
3 | 6.3 | 1.75 | 75 | 2950 | 2.86 | 5.5 | 2 | 45 | 138 |
| 4 | 100 | 3.81 | 7.5 | |||||||
| 5 | 125 | 4.77 | 7.5 | |||||||
| 6 | 150 | 5.72 | 11 | |||||||
| 7 | 175 | 6.67 | 11 | |||||||
| 8 | 200 | 7.63 | 15 | |||||||
| 9 | 225 | 8.58 | 15 | |||||||
| 10 | 250 | 9.53 | 18.5 | |||||||
| 11 | 275 | 10.5 | 18.5 | |||||||
| 12 | 300 | 11.44 | 18.5 | |||||||
| D12-25 DG12-25 DGR12-25 |
3 | 12.5 | 3.47 | 75 | 2950 | 4.73 | 7.5 | 2 | 54 | 146 |
| 4 | 100 | 6.3 | 11 | |||||||
| 5 | 125 | 7.88 | 11 | |||||||
| 6 | 150 | 9.46 | 15 | |||||||
| 7 | 175 | 11 | 15 | |||||||
| 8 | 200 | 12.61 | 18.5 | |||||||
| 9 | 225 | 14.18 | 18.5 | |||||||
| 10 | 250 | 15.67 | 22 | |||||||
| 11 | 275 | 17.34 | 22 | |||||||
| 12 | 300 | 18.9 | 30 | |||||||
| D25-30 DG25-30 DGR25-30 |
3 | 25 | 6.94 | 90 | 2950 | 9.88 | 15 | 2.2 | 62 | 160 |
| 4 | 120 | 13.1 | 18.5 | |||||||
| 5 | 150 | 16.47 | 22 | |||||||
| 6 | 180 | 19.77 | 30 | |||||||
| 7 | 210 | 23.1 | 30 | |||||||
| 8 | 240 | 26.4 | 37 | |||||||
| 9 | 270 | 29.65 | 37 | |||||||
| 10 | 300 | 32.9 | 45 | |||||||
| D46-30 DG46-30 DGR46-30 |
3 | 46 | 12.8 | 90 | 2950 | 16.11 | 22 | 70 | 3.0 | 164 |
| 4 | 120 | 21.48 | 30 | |||||||
| 5 | 150 | 26.85 | 37 | |||||||
| 6 | 180 | 32.21 | 37 | |||||||
| 7 | 210 | 37.58 | 45 | |||||||
| 8 | 240 | 42.95 | 55 | |||||||
| 9 | 270 | 48.32 | 55 | |||||||
| 10 | 300 | 53.69 | 75 | |||||||
| D25-50 DG25-50 DGR25-50 |
3 | 25 | 6.94 | 150 | 2950 | 18.9 | 30 | 54 | 2.7 | 196 |
| 4 | 200 | 25.2 | 30 | |||||||
| 5 | 250 | 31.5 | 37 | |||||||
| 6 | 300 | 37.8 | 45 | |||||||
| 7 | 350 | 44.1 | 55 | |||||||
| 8 | 400 | 50.4 | 75 | |||||||
| 9 | 450 | 56.7 | 75 | |||||||
| 10 | 500 | 63.0 | 75 | |||||||
| 11 | 550 | 69.3 | 90 | |||||||
| 12 | 600 | 75.6 | 110 | |||||||
| D46-50 DG46-50 DGR46-50 |
3 | 46 | 12.8 | 150 | 2950 | 29.83 | 37 | 63 | 2.8 | 210 |
| 4 | 200 | 39.77 | 45 | |||||||
| 5 | 250 | 49.11 | 55 | |||||||
| 6 | 300 | 59.65 | 75 | |||||||
| 7 | 350 | 69.6 | 90 | |||||||
| 8 | 400 | 79.48 | 90 | |||||||
| 9 | 450 | 89.48 | 110 | |||||||
| 10 | 500 | 99.42 | 110 | |||||||
| 11 | 550 | 109.36 | 132 | |||||||
| 12 | 600 | 119.36 | 132 | |||||||





| fault | reason | Solution method |
| 1. The pump does not absorb water, and the pressure gauge pointer swings violently. | Insufficient irrigation and water intake, resulting in air leakage at the connection between the pipeline and the instrument. | Check if the bottom valve is leaking, fill it with water, tighten or repair the leak. |
| 2. The water pump is not producing water, and the vacuum gauge indicates high vacuum. | The bottom valve is not open or blocked, the resistance of the suction pipeline is too high, and the suction height is too high. | Check the bottom valve, replace the water pipe, and lower the suction height. |
| 3. The pressure gauge has pressure, but it still does not release water. | The resistance of the outlet pipe is too high, the rotation direction is incorrect, the impeller is blocked, and the pump speed is insufficient. | Check or shorten the water pipe. Check the motor, remove any dirt from the impeller, and increase the pump speed. |
| 4. The flow rate is lower than the design requirements. | The water pump is blocked, the sealing ring is worn too much, and the speed is insufficient. | Clean the water pump and pipeline, replace the sealing ring, and increase the pump speed. |
| 5. The pump consumes too much power. | The packing gland is too tight and heats up, the impeller is worn, and the pump flow rate increases. | Adjust the tightness of the packing gland, check if the pump shaft is bent, replace the impeller, increase the water outlet resistance, and reduce the flow rate. |
| 6. The sound inside the pump is abnormal and the pump is not producing water. | Excessive resistance in the suction pipe, air leakage in the suction pipeline, and high temperature of the conveyed liquid. | Check the suction pipe and bottom valve, block any leaks, reduce the suction height, and lower the water temperature. |
| 7. The water pump vibrates and the bearings overheat. | The motor and pump are not concentric, and the bearings are short of oil or worn. | Adjust the coaxiality between the motor shaft and the pump shaft, add oil or replace the bearings. |