Up to 6 lasers
CytoFLEX LX flow cytometerSix laser options are provided for the scientific research field, offering up to 21 fluorescence channels. Users can choose from UV 355nm or near UV 375nm lasers, as well as 405nm purple, 488nm blue, 561nm yellow green, 638nm red, and 808nm infrared lasers. It, like the CytoFLEX system, draws on innovative technology from the telecommunications industry and its performance is comparable to instruments four times its size. As part of the CytoFLEX platform, these instruments feature adjustable bandpass filters with high sensitivity and wide dynamic range, as well as flexible upgrades that can be achieved by activating other parameters.
CytoFLEX LX flow cytometer
Up to 6 laser excitation performance and high detection sensitivity, compact structure, convenient for monochrome and multi-color analysis.
Configuration Selection
7 flexible configurations to easily meet your application needs.
Select (6) lasers from the following options: 355 or 375nm, 405nm, 488nm, 638nm, 561nm, and 808nm.
Design dimensions
Cell analyzer (with or without plate loader)
60.5cm x 73.3cm x 45.1 cm
Fluid containers and fluid container racks
25cm x 25cm x 25cm
5mL (12 x 75mm) polystyrene and polypropylene flow tube
1.5mL and 2mL microcentrifuge tubes
Automatic optical calibration, no need to adjust the optical system
fluid flow
Users can replace (maintenance free) the ultra-low pressure peristaltic sheath and sample delivery system sheath fluid filter, as well as the sample itself.
• Set flow rate for exit: 10, 30, and 60 μ m/min
Custom adjustment of tassel range: 10-240 μ m/min, increment of 1 μ m
Testing performance and resolution
FITC:<30 equivalent soluble fluorescein molecules (MESF-FITC)
PE:<10 Equivalent Soluble Fluorescein Molecules (MESF-PE)
Featuring a 7-order of magnitude ultra wide dynamic data display range, 16777216 channel resolution, and a loading speed of 30000 particles per second.
Innovative wavelength division multiplexing (WDM) detection module; Dual port WDM module.
The proprietary flow chamber design with integrated optical components improves sensitivity and multi wavelength detection capability.
The integrated optical module design using flow chamber and Homodyne forward scattering technology has achieved higher stability and detection capability.
Easily detect 80nm particles with 405nm purple light lateral angle scattering parameters.
Simultaneously obtaining lateral scattered light from 488nm and 405nm for flexible detection of various particles.
CytoFLEX's CytExpert software
CytExpert software can achieve visualization of data collection and analysis modules
The industry standard FCS 3.0 file format supports the use of third-party software.
Full matrix optical compensation supports both automatic and manual compensation.
The compensation library allows users to store and retrieve compensation overflow storage containers for fuel.
• Equipped with free full-featured analysis software, saving analysis time.