Chengde Shenghe Intelligent Instrument Co., Ltd
Building 4, Chengde High tech Intelligent Garden, Liandong U Valley, Dongxiying Area, High tech Zone, Chengde City
| flow range | 0-3.0 L/min、0-6.0 L/min、0-8.0 L/min、0-15 L/min |
| Pressure range | 10 bar, 16 bar, 25 bar (aluminum body) |
| connection method | Quick twist connector (Φ 12 × 1.5 hose), hose connection (Φ 10 hose), internal thread (G/NPT 1/4 '~2') |
| alarm output |
AC 90-250V (normally open/normally closed), DC 10-30V (two-wire/NPN/PNP) |
| core functionality |
2. It can lower the traffic alarm and provide real-time fault warning 3. The large section bow valve is anti blocking and can clean the measuring tube online without interrupting the waterway 4. Compatible with single/double mechanical seals, providing pressure regulation and display options |
By sealing type
SHD (Double Mechanical Seal)Equipped with pressure control knob, no pressure gauge (customer provided)
According to the connection method
Hose connection (Φ 10/Φ 12 hose, optional 1/4 ', 3/8', 1/2 'connectors).
Threaded connection (G/NPT 1/4 '~1/2' internal thread).
Card sleeve connection (suitable for industrial hard pipes).
According to installation method
S-shaped floor bracket: suitable for stable installation on the ground.
B-type cantilever bracket: saves space and can be fixed on the side wall of the equipment.
Attachment extensionFilter (G) is equipped for high impurity working conditions, and check valve (V) needs to be installed to prevent backflow.
working principleThe cooling water flows through the inlet distribution plate float measuring tube, and the float moves under the fluid thrust. When stable, the white circular ring points to the corresponding flow scale; The pressurized water flows through the outlet into the shaft seal to achieve cooling and lubrication.
State diagnosis logic
Normal: The flow rate and pressure are consistent with the target values.
Leakage: Flow rate ↑+pressure ↓.
Blockage: Flow rate ↓+pressure ↑.
Water supply failure: flow rate ↓+pressure ↓.
Chengde Shenghe Intelligent Shaft Seal Water Flow MeterInstallation specifications
Priority should be given to horizontal installation to ensure free movement of the float and avoid interference of bubbles with readings.
Install a filter before the entrance to prevent impurities from blocking the measuring tube or sealing surface.
The alarm line should be wired correctly according to the voltage type to ensure stable signal transmission.
Chengde Shenghe Intelligent Shaft Seal Water Flow Meterroutine maintenance
Regularly check the flexibility of the float, and if it is stuck, clean the transparent measuring tube online (without cutting off the water).
Calibrate the traffic alarm threshold monthly to avoid false positives/false negatives.
Quarterly inspection of bow valves and joints to prevent water leakage or blockage.
Fault handling
Float unresponsive: Check if the filter is clogged and if the water circuit is vented.
Abnormal pressure: Check the water supply source with a single seal, adjust the pressure knob with a double seal, and investigate pipeline leaks.
Alarm false triggering: recalibrate the alarm value, check the wiring and power stability.
First, confirm the type of equipment seal (single/double mechanical seal), the required flow range (such as 0-6 L/min commonly used for pump shaft seals), and the pressure rating (working pressure+safety margin ≥ 1.2 times).
Select the connection method (hose/thread/sleeve) according to the on-site pipeline, and choose the cantilever bracket due to limited space.
Media containing particles or impurities must be equipped with filters, and it is recommended to add check valves to prevent backflow during continuous operation.
The alarm function needs to be matched with PLC/DCS signal types (AC/DC, normally open/normally closed) to ensure system linkage.