E-mail
hytdtec@163.com
-
Phone
17694800211,15811077873
-
Address
Room 6208A, Kangde Building, No.17 Shangdi 6th Street, Haidian District, Beijing
Beijing Hongyuan Tongda Technology Co., Ltd
hytdtec@163.com
17694800211,15811077873
Room 6208A, Kangde Building, No.17 Shangdi 6th Street, Haidian District, Beijing
Our company customizes special process requirements for customers定制high precisionConstant temperature and humidity testing chamberTest box,Unconventional constant temperature and humidity chamber.
The accuracy level of temperature and humidity can reach the level of sensor calibration box. The following table shows a case of a 1 cubic meter test chamber. Please contact us for customization.
Project Name |
1 cubichigh precisionConstant temperature and humidity testing chamberTechnical parameters and requirements |
Product Model |
定制。 |
Test cabin volume |
Workspace 1.0 m3. 1000 × 800 × 1250mm, adjustable according to actual needs. |
External volume of test cabin |
Width x Height x Depth: 1300 x 1800 x 2700mm. |
meet the standard |
Both parties agree. |
temperature and humidity |
Temperature: -30~80 ℃, control accuracy ± 0.3 ℃; Relative humidity: -30~0 ℃, uncontrolled, only displayed; Other, control accuracy ± 3%; The absolute humidity control range is 3.0-95g/kg dry air. |
uniformity |
Temperature uniformity ± 0.3 ℃, relative humidity uniformity ± 2%. |
fresh air |
Adjust the fresh air system according to temperature and humidity control requirements. |
inside cabin |
SUS304 stainless steel plates and profiles. |
sealing material |
Whole welding and polishing, with a small amount of silicone strip. |
air circulation |
The internal and external cabin jacket design ensures the uniformity of airflow and temperature and humidity in the workspace with high air volume. |
air conditioning system |
Low temperature air conditioning+room temperature air conditioning dual air conditioning system, imported compressor. (Danfoss or equivalent grade) |
Humidification system |
Intelligent selection and control based on different humidity requirements. |
control system |
Computer control can record temperature and humidity data in the cabin at any time. In addition, 10 sets of sensor signals (voltage or current) required for calibration can be collected and directly output to the computer to form a calibration comparison report. |
sensor |
The temperature and humidity sensor adopts the imported Rotronic brand HC2A-S3, and the test data is displayed on the system interface. |
equipment power supply |
Power supply 380V, power: 5kW. |