Welcome Customer !

Membership

Help

Dalian Hantai Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Dalian Hantai Technology Co., Ltd

  • E-mail

    hantaikeji@163.com

  • Phone

    13889538285

  • Address

    Xinzhaizi Xinshou Dongyuan, Ganjingzi District, Dalian City, Liaoning Province

Contact Now

Cone/Needle Penetration Tester

NegotiableUpdate on 06/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

This instrument is designed and manufactured in accordance with the technical requirements and relevant regulations of GB/T 4509-1998/2010 "Determination of Penetration of Petroleum Asphalt", GB/T269 "Determination of Cone Penetration of Lubricating Greases and Stone Greases" and JTG E20-2011 "Test Code for Asphalt and Asphalt Mixtures in Highway Engineering" in the People's Republic of China's transportation industry standard T0604-2011 "Asphalt Penetration Test". It is mainly suitable for testing the penetration of asphalt and the cone penetration of lubricating grease (or stone grease).

Product Details

Functional Features

Display accuracy: The measured cone penetration value can be directly read through the LCD screen, which is intuitive and accurate (up to one percent).

Structure: The flexible and lightweight cone adjustment lifting mechanism can be roughly or finely adjusted, with digital setting/control of timing time. The timing electromagnetic mechanism locks the falling cone and cone rod, and the steel structure work tool has a flexible working stroke; Equipped with a full cone.

● It has the functions of coarse and fine adjustment of the lifting frame, easy adjustment, and accurate needle alignment.

Equipped with a tamper, a constant temperature bath, and automatic temperature control for the water bath, the instrument is versatile and cost-effective.

Technical Parameter

1. Measurement range: (0-600) needle penetration;

2. Needle insertion time control device: can select 5 seconds, 8 seconds, 10 seconds, 12 seconds, 30 seconds, and 60 seconds respectively, with a time error of less than ± 0.1 seconds;

3. Resolution: 0.01mm;

4. Needle insertion accuracy: ± 1 needle insertion degree;

5. Standard needle: 50mm, 2.5g ± 0.05g (basic configuration, see Section 4, Instrument Accessories Configuration Table for details);

6. Heater power: 200W;

7. Temperature control accuracy: (25 ± 0.1) ℃ (note: the ambient temperature should not exceed 20 ℃);

8. Temperature control method: high-precision digital temperature controller;

9. Thermostatic bath: for hard glass tanks;

10 standard cone: (102.5 ± 0.05) g, in compliance with the specifications of national standard GB/T 269;

11. Working power supply: AC (220 ± 10%) V, 50Hz, power consumption not exceeding 300W.