The CZ-3 computerized fully automatic penicillin bottle verticality deviation tester is designed and manufactured according to standards such as QB 2357-1998 Polyester (PET) Non carbonated Beverage Bottles, QB/T 1868-2004 Polyethylene Terephthalate (PET) Carbonated Beverage Bottles, and the national drug packaging container YBB00192003 Vertical Axis Deviation Measurement Method. It is specialized in measuring the verticality deviation of various bottle containers, with simple operation, high centering and measurement accuracy. 1. Microcomputer control, touch screen display, menu interface, mechatronics design. 2 Real time display
CZ-3 typeComputerized fully automatic penicillin bottle verticality deviation testerIntroduction
CZ-3Computerized fully automatic penicillin bottle verticality deviation testerDesigned and manufactured according to standards such as GB/T8452-2008 Glass Bottle and Can Vertical Axis Deviation Test Method, QB 2357-1998 Polyester (PET) Non carbonated Beverage Bottles, QB/T 1868-2004 Polyethylene Terephthalate (PET) Carbonated Beverage Bottles, and YBB00192003 National Drug Packaging Container Vertical Axis Deviation Determination Method, this product is specialized in measuring the verticality deviation of various bottles and containers. It is easy to operate, has high centering and measurement accuracy.
1、 Product Features
1. Microcomputer control, touch screen display, menu interface, mechatronics design.
2. Real time display of measurement values and experimental process curves, automatic capture of large and small values, and automatic calculation of axis deviation values.
3. It can print large values, small values, and axis deviation values, and automatically record measurement results.
2、 Technical indicators
1. Small division value: 0.01 (0.001 optional) mm, range: 0-12.7mm
2. Clamping range: diameter 5-100mm, height 500mm, net weight 20kg
Part1
Product Application
Ampoule bottle, penicillin bottle, glass infusion bottle, beer bottle, white wine bottle, red wine bottle, beverage bottle, mineral water bottle.
Part2
Product Features
1. Microcomputer control, LCD display, menu style interface, mechatronics design.
2. Real time display of measurement values, automatic statistics of large, small, and axis deviation values.
3. Each measurement result, as well as the maximum, minimum, and axis deviation values, can be printed.
4. The instrument can store data, and each set of data measurement points can be viewed with recording intervals.
5. The instrument is equipped with professional testing software, and the LCD screen can display the experimental process curve in real time, which can be switched according to the screen.
Part3
Product parameters
Sample diameter: 3-200mm
Instrument range: 0-12.7mm
Division value: 0.001mm with an error of less than 0.1mm
Measurable height: 5mm-500mm
Dimensions: 400 × 270 × 680mm
Weight: Approximately 18kg
Part4
technical standard
YBB0033203-2015 Sodium Calcium Glass Injection Bottles
YBB00032004-2015 Sodium Calcium Glass Controlled Oral Liquid Bottles
GB/T 8452-2008 "Test Method for Vertical Axis Deviation of Glass Bottles and Jars"
YBB0033202-2015 "Low Borosilicate Glass Ampoule"
Part5
Product configuration: Standard host, measuring chuck, and mini printer.