Application of hot deformation and Vicat softening point temperature measuring instrument:The thermal deformation and Vicat softening point temperature tester is used to measure the thermal deformation and Vicat softening point of non-metallic materials such as plastics, rubber, nylon, and electrical insulation materials.
definition:
Thermal deformation:Deformation temperature under load (bending stress under three-point loading) (determination of load deformation temperature);
Vicat softening point temperature:The temperature at which the specified needle penetration phenomenon occurs in a plastic sample under controlled testing conditions (plastic Vicat softening temperature test method).
Standard for thermal deformation and Vicat softening point temperature measuring instrument:ASTM-D1525、 ASTM-D648、DIN53460、DIN53461、ISO-306、ISO-75;
Specification of hot deformation and Vicat softening point temperature tester:
1 Number of workstations: 3 or 6, requiring oil discharge ports;
2 Measurement method: HDT+VICAT;
3 Control mode: computer system;
4 Temperature control range: room temperature -300℃(Other temperatures are optional);
5 Heating rate: 50℃/hAnd 120℃/hCan be set, using imported temperature modules or temperature control meters for temperature control;
6 Temperature fluctuation value: ± 0.2℃;
7 Temperature sensing: Measurement around the sample, with each temperature measurement group having a temperature sensing device above each sample, which can adjust the height position according to the shape of the sample and display the temperature separately;
8 Heating medium: Methyl silicone oil (below 200 cm-1, ignition point 300)℃Above), randomly equipped;
9 Deformation measurement: Korean Dongdu LVDT displacement sensor;
10 Mobile LVDT sensor fixed bracket for quick adjustment of sensing position;
11 Variable measurement range: 0.001-4mm (LVDT sensing);
12 Hot deformation specimen span: 64mm, 100mm, and 101.6mm available for selection;
13 Sample holder and weight bracket, electric take-off and landing, no need to move weights when replaying samples, can quickly place samples;
14 Cooling method: water cooling or compressor cooling;
15 Meet the requirements of the new national standard for flat test specimens, with a total rack weight of less than 64g. The load rod is designed with an air guide ring, which can provide vertical frictionless action;