Comprehensive testing room for battery safety performance

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The comprehensive testing laboratory for battery safety performance is mainly used to test the safety performance of batteries when they are affected by external destructive forces. Except for special devices, the equipment can be manually and remotely controlled to monitor the testing process, making operation more simple, convenient, and safe.

Product Details

product name Comprehensive testing room for battery safety performance

Product Model HT-6100

Product Usage Comprehensive Testing Laboratory for Battery Safety PerformanceMainly used to test the safety performance of batteries when subjected to external destructive forces. The entire scheme, except for special devices,equipmentThe device can be manually and remotely controlledcomeControl,canMonitor the testing processMake the operation simplerJieconvenientsafe The comprehensive testing laboratory for battery safety performance includesBattery compression, needle puncture, heavy object impact, fallingshort circuit(room temperature, high temperature short circuit), internal short circuitCombustion, thermal shockOvercharge, over discharge, and forced discharge testsHigh altitude transportation and other experiments.All testing items can be selected according to customer needsIf there are special non-standard requirements, they can be customized according to the requirements.


Specification and technical parameters of battery compression test chamber:

Transmission mode: hydraulic (or pneumatic)

Battery compression plate: standard circular compression plate, easy to disassemble and replace (size is diameter)150mm)

Squeezing degree: Squeezing continues until the actual pressure reaches13kN ± 0.2kN, once the pressure is reached after holding for 1 minute, the equipment will automatically release the pressure and complete the extrusion;

Pressure range:1KN~20KN (commonly used 13KN)

Pressure display accuracy:0.1N, Sensor resolution: 1/10.00;

Unit Conversion:kg, N, lb、KN

Data sampling frequency:80 times/second

Compressed space:520 * 500 * 445mm (width * height * depth)

Squeezing stroke of the machine:300mm

batterySpecifications and Technical Parameters of Acupuncture Test Chamber:

Steel needle specification: length is100mm ф 2mm~ф 8mm high temperature resistant steel needle

Distance from the needle tip to the lower part: the plane where the battery is placed200mm

Clamping distance:10mm

through wear 力:500~150kg

Power display: pressure sensing LCD screen display

Effective stroke of oil cylinder:300mm

Drive mode: hydraulic or pneumatic drive

Box type equipment: explosion-proof, fireproof, corrosion-resistant, easy to clean

Explosion proof inner box material: Stainless steel material in the box bodyAdd iron fluorine solution adhesive tape at 1/3 of the location, which is heat-resistant, corrosion-resistant, insulated, and easy to clean

Delay function:0-99 (H/M/S can be freely set and adjusted for testing time)

Machine size: Width730 * Depth 775 * Height 1910mm

Using power supply:AC220V, 50HZ, 13A

Equipment power:2.2KW

Whole machine weight: approximately260kg

Specification and technical parameters of battery heavy impact test chamber:

Falling ball weight:9.1kg or 10Kg

Impact height:500~1200mm (limit adjustable freely)

Altimeter display: accurate to5mm

horizontal Bar:15.8mm (5/8 inch) steel rod

Impact method: Lift the falling ball to a certain height and release it. The falling ball falls freely in the vertical direction without tilting or shaking

Upper and lower impact surfaces:A3 steel plate baked paint

electricity Source:3∮,AC220V±10 ﹪, 60Hz,3A

Specification and technical parameters of battery drop test chamber:

Maximum weight of test piece:2kg±100g

Drop height:300-1500mm (adjustable)

Drop height ruler: stainless steel material minimum indicator1mm

Clamping method: Air pressure adsorption type, any part can be dropped

Falling floor medium: cement board, acrylic board, stainless steel (choose one from three)

Drop method: multiple angles (diamond, angle, surface)

Bottom plate size:3500*600*200mm

Specification and Technical Parameters of Temperature Controlled Battery Short Circuit Test Chamber:

Working voltage: AC220V 50Hz~60Hz

Impulse voltage:AC 1kv/1.2~50us(峰值)1min

Maximum voltage of measurable battery:100V

DC response time:≤5us

Maximum short-circuit current:1000A, The maximum allowable current passing through is 4le, 5s

Device internal resistance:≤5mΩ

Mechanical lifespan:300,000 times

Working environment: Temperature-10 ℃~100 ℃, humidity 10~90%, no condensation

Specifications and technical parameters of battery high-altitude low-pressure simulation test chamber:

Inner box material: stainless steel material

Outer box material: Cold rolled steel plate with baked paint treatment

Material of takeover: specially made steel material

Sample partition: made of stainless steel material

Inner box size:30 * 30 * 30mm (expandable as needed)

warm control Table: Can achieve total heating time control, different from ordinary temperature control meters

Vacuum degree display mode: pointer vacuum degree control gauge, pressure range is1kPa, Commonly used 11.6KPA

Air pressure control mode: automatic control of air input and output, automatic control of constant air pressure

Timing method: Each time interval starts from1 minute to 100 hours

Box door design: The safety observation glass box has a tempered glass observation window on the door, allowing users to clearly observe the inside of the box. The insulation layer uses high-temperature resistant silicone sealing rings

Specification and technical parameters of battery thermal shock test chamber:

Temperature range: normal temperature~200℃

Temperature display accuracy:±0.1℃

Temperature uniformity:±2℃

Internal dimensions: approximately350 * 400 * 400mm (can be protected according to needs)

Heating time:5 ± 2 ℃/min (average temperature rise, non-linear no-load)

Temperature controller: capable of controlling the total heating time, different from ordinary temperature controllers

Specification and technical parameters of battery combustion test chamber:

Burner: using a Bunsen burner with an inner diameter of9.5mm, Approximately 100mm in length (including burner and support frame, metal mesh cover, battery placement metal mesh screen)

Flame application time:0-99.9 seconds ± 0.1 seconds

Timer:LED, 0~9999S

Test circular hole surface diameter:102mm

Test cover width:24 "(610mm), octagonal

Test cover height:12″(305mm)

electricitySource: 3 ∧, AC220V ± 10%, 60Hz, 3A