Comprehensive drug two box stability test boxIt is a device that integrates temperature, humidity, lighting, and ultraviolet illumination testing conditions, and can simultaneously meet the requirements of long-term testing, accelerated testing, high-temperature testing, and strong light irradiation testing specified in the pharmacopoeia. It is the preferred solution for pharmaceutical companies to conduct drug stability testing.
Comprehensive drug two box stability test boxProduct Features
The selection of this series can be based on specific test conditions and site requirements.
Adopting a multi-channel touch screen temperature and humidity control instrument, it integrates functions such as temperature, humidity, lighting, UV, printing, USB export of recorded data, communication, cumulative timing, alarm prompts, etc.
The main technical parameters of the equipment are superior to the technical requirements stipulated by GMP, and also meet the relevant requirements stipulated by ICH and FDA.
Equipped with temperature and humidity deviation, power outage and other SMS alarms, wireless or wired RS485 communication interface, facilitating centralized monitoring of equipment and management of multiple devices.
Adopting multi-channel touch screen temperature and humidity control instrument
Temperature and humidity deviation, power outage and other SMS and phone alarm prompts
Third level permissions and audit tracking
Wireless or wired RS485 communication interface
Electronic data storage and export
real-time printing
Accumulated timing
The high temperature of the constant temperature and humidity incubator does not meet the set indicators in the experiment
If the temperature change of the incubator does not reach the required temperature value for the experiment, the heating electrical system of the incubator can be checked and the faults can be eliminated one by one. If the temperature of the constant temperature and humidity incubator rises slowly, it is necessary to check the air circulation system to see if the regulating baffle of the air circulation is open normally. Otherwise, check if the motor of the air circulation is running normally. If the temperature overshoot is severe, it is necessary to adjust the PID setting parameters. If the temperature rises directly and is protected against overheating, then the incubator controller has malfunctioned and the control instrument needs to be replaced.