Welcome Customer !

Membership

Help

Guangzhou Philomen Scientific Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Guangzhou Philomen Scientific Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    13th Floor, Shanglou International, No. 179 Tianhe North Road, Guangzhou City

Contact Now

Comixsil HAC liquid chromatography column

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Comixsil HAC liquid chromatography column separation mechanism: ionizable acidic and basic groups are incorporated into the hydrophilic chain, which has anion/cation exclusion/exchange function, can form hydrogen bonds and exhibit HILIC (hydrophilic interaction chromatography) effect, effectively retaining strong hydrophilic compounds while achieving accurate analysis of anions and cations.

Product Details

  • Comixsil HAC liquid chromatography columnSpecification ModelThere are two options for particle size: 3 μ m and 5 μ m. There are various combinations of column length and inner diameter, such as 2.1x50mm, 2.1x100mm, 3.0x150mm, 4.6x250mm, etc. The corresponding product numbers are FMB-HAC3-BUNU, FMD-HAC3-BUNU, FMF-HAC5-YONU, FMG-HAC5-YONU, etc.

  • Comixsil HAC liquid chromatography columnapplication fieldCan be used to separate aminoglycosides from streptomycin and dihydrostreptomycin, analyze 8 aminoglycoside substances, separate 11 nucleic acid bases and nucleosides, etc. It can also be used to analyze metal ions, such as simultaneous analysis of zinc, calcium, copper and other metal ions and corresponding anions, separation of calcium and zinc ions, etc. When analyzing nicotine, compared to C18 and Hilic columns, it can avoid weak retention, tailing, and reproducibility issues under acidic conditions.


Comixsil HAC is particularly suitable for analyzing the following types of substances:
  1. Strong hydrophilic compoundDue to its hydrophilic interaction chromatography (HILIC) function, it can effectively retain compounds with strong polarity and hydrophilicity, solving the problem of weak retention of such substances on traditional reverse phase chromatography columns.
  2. Yin Yang ionic substancesDue to the incorporation of ionizable acidic and basic groups in the chromatographic column, it has the functions of anion/cation exclusion and exchange, and can accurately analyze various anions and cations, such as metal ions such as zinc, calcium, copper, and corresponding anions.
  3. Specific biological small moleculesSuch as aminoglycoside antibiotics, nucleic acid bases and nucleosides, can achieve good separation effects.
  4. Substances such as nicotine that are prone to retention and peak shape issuesWhen analyzing nicotine, compared to C18 columns and ordinary Hilic columns, it can avoid weak retention, tailing, and poor reproducibility under acidic conditions, and performs better.

  5. Sample propertiesIf the analyzed sample matrix is complex (such as containing a large amount of impurities, highly corrosive substances, or proteins in biological samples), it will accelerate the contamination or loss of chromatographic column packing and shorten the service life; And clean samples can prolong the column efficiency retention time.
  6. Terms of UseIncluding the pH value of the mobile phase (extreme acid-base conditions may damage the stationary phase), flow rate (excessive flow rate will increase column pressure and accelerate packing wear), column temperature (excessive temperature may affect the stability of the stationary phase), etc. Reasonable control of these parameters can prolong the service life.
  7. maintenanceRegular column flushing (such as rinsing residual samples with appropriate solvents after analysis), avoiding dry columns, and proper storage (such as short-term storage with mobile phase and long-term storage with pure organic solvents) can effectively extend the service life of chromatography columns.


Under normal use and proper maintenance, the service life of such chromatography columns can typically reach hundreds to thousands of injections. The specific lifespan needs to be determined based on the actual usage scenario. If there is an abnormal increase in column pressure, deterioration of peak shape (such as tailing or splitting), or a decrease in separation, it may mean that the chromatographic column needs to be replaced.


Item number Description Specifications
FMB-HAC5-BONU Comixsil HAC 5u 2.1x50
FMD-HAC5-BONU Comixsil HAC 5u 2.1x100
FMF-HAC5-BONU Comixsil HAC 5u 2.1x150
FMG-HAC5-BONU Comixsil HAC 5u 2.1x250
FMB-HAC5-YONU Comixsil HAC 5u 3.0x50
FMD-HAC5-YONU Comixsil HAC 5u 3.0x100
FMF-HAC5-YONU Comixsil HAC 5u 3.0x150
FMG-HAC5-YONU Comixsil HAC 5u 3.0x250
FMB-HAC5-EONU Comixsil HAC 5u 4.6x50
FMD-HAC5-EONU Comixsil HAC 5u 4.6x100
FMF-HAC5-EONU Comixsil HAC 5u 4.6x150
FMG-HAC5-EONU Comixsil HAC 5u 4.6x250
FMB-HAC3-BONU Comixsil HAC 3u 2.1x50
FMD-HAC3-BONU Comixsil HAC 3u 2.1x100
FMF-HAC3-BONU Comixsil HAC 3u 2.1x150
FMG-HAC3-BONU Comixsil HAC 3u 2.1x250
FMB-HAC3-YONU Comixsil HAC 3u 3.0x50
FMD-HAC3-YONU Comixsil HAC 3u 3.0x100
FMF-HAC3-YONU Comixsil HAC 3u 3.0x150
FMG-HAC3-YONU Comixsil HAC 3u 3.0x250
FMB-HAC3-EONU Comixsil HAC 3u 4.6x50
FMD-HAC3-EONU Comixsil HAC 3u 4.6x100
FMF-HAC3-EONU Comixsil HAC 3u 4.6x150
FMG-HAC3-EONU Comixsil HAC 3u 4.6x250
FMF-HAC5-NONU Comixsil HAC 5u 10x150
FMG-HAC5-NONU Comixsil HAC 5u 10x250