Welcome Customer !

Membership

Help

Beijing Keda Road Industry Testing Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Beijing Keda Road Industry Testing Instrument Co., Ltd

  • E-mail

    851407415@qq.com

  • Phone

    15611883444

  • Address

    38 Kechuang 5th Street, Beijing Economic and Technological Development Zone, Beijing, China

Contact Now

Combustion method asphalt content analyzer

NegotiableUpdate on 01/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The combustion method asphalt content tester Cleveland open flash point tester is suitable for determining the flash point and ignition point of petroleum products using the standard GB/T3536, ISO2592, ASTMD92, IP36 (Cleveland open cup method) except for fuel oil and petroleum products with an open cup temperature below 79 ℃. The asphalt flash point meter complies with the JTJ052-2000 standard of the Ministry of Transport.
Product Details

Combustion method asphalt content analyzerTechnical Specifications:

Automatic swipe ignitionElectric furnace heating power 400WTemperature control adopts thyristorContinuous temperature regulation

Combustion method asphalt content analyzerSYD-3536 Cleveland Open Flash Point Tester/Flash Point Tester Experimental Procedure:1、 Start heating the sample at a rapid rate of 14 ℃/min-17 ℃/min. When the temperature reaches 56 ℃ before the expected flash point, reduce the heating rate and control the rate at 5.5 ℃/min ± 0.5 ℃/min before the flash point of 28 ℃.2、 Starting from 28 ℃ before the expected flash point, sweep the test flame of the igniter horizontally along the center of the test cup with a radius of 150mm every 2 ℃ for about 1 second.3、 When a blue flame appears on the liquid surface of the sample and extinguishes immediately, record the temperature as the flash point of the sample.4、 Continue heating at a rate of 5.5 ℃/min ± 0.5 ℃/min.5、 When the sample comes into contact with the flame and immediately ignites, and can continue to burn for no less than 5 seconds, stop heating and record the temperature as the ignition point of the sample.SYD-3536 Cleveland Open Flash Point Tester/Flash Point Tester Technical Parameters:1. Working power supply: AC 220V ± 10%, 50Hz.2. Heating device: Quartz tube electric furnace heating, no open flame, explosion-proof, continuously adjustable power from 0 to 600W.3. Scanning device: automatic scanning.4. Temperature gauge: -6~400 ℃, with a division of 2 ℃, in accordance with the technical specifications of GB/T514 for liquid thermometers used in petroleum product testing.5. Ignition device: ⑴ Ignition source: Gas (or other civilian combustible gas, the same below);6. Environmental temperature: -10 ℃ to 50 ℃.7. Relative humidity: ≤ 85%.8. Power consumption of the whole machine: not exceeding 650W.9. Cleveland Cup: Material H62, inner diameter 63.5 ± 0.25mm, depth 33 ± 0.1mm, distance from upper edge 9.5 ± 0.5mm, with a circular marking on the inner wall10. Igniter: Automatic scratch ignition, nozzle diameter of Φ 0.6-0.8mm11. Temperature gauge: -6~400 ℃, with a division of 2 ℃, in accordance with GB514-7512. Electric furnace heating power: 400W continuous temperature control13. Power supply: 220V ± 10% 50Hz14. Dimensions and dimensions: 350 × 260 × 170mm15. Weight: 6kg