-
E-mail
178452452@qq.com
-
Phone
13082764611
-
Address
Shandong Wucheng Luquan Tun Development Zone
Dezhou Gengzi Environmental Technology Co., Ltd
178452452@qq.com
13082764611
Shandong Wucheng Luquan Tun Development Zone

Application range of closed cooling tower: It is converted from a cross flow open tower and suitable for projects with multiple parallel combinations of various water volumes, with relatively low efficiency.
feature
1. Using fiberglass outer panel, even if the operating environment is relatively humid, it is not easy to rust, the outer panel is not easy to fade, and can be used for a long time.
2. Cross flow design, the power of the air supply fan is relatively small, the noise can be reduced, and because the spray water falls through the packing, the sound of water when it falls is also small.
3. The fan blades are made of wing shaped hollow aluminum alloy, which has the characteristics of high strength, light weight, easy balance adjustment, and large air volume. It can be driven by a low-power motor; The cross flow form reduces the resistance that the fan overcomes, and compared to the counter flow type, it can have a larger air volume at lower power; Even with a large amount of water, the water pressure head is significantly reduced, resulting in a more significant energy-saving effect.
4. Optimize the arrangement and enhance the heat affected effect
The copper coil is connected to the riser through threads for easy disassembly; Optimize the arrangement of coils, change from sequential arrangement to cross arrangement, and enhance heat transfer efficiency.
5. Reduce the operating cost of the cooling system
Due to the operation of circulating water in a closed state, it will not be contaminated and there is no need to spend any cost on exchanging circulating water. At the same time, due to the prevention of corrosion of the circulation system by air pollutants such as sulfide gases, dust, microorganisms, etc., the heat exchanger of the refrigeration unit is not prone to scaling and does not require drugs, reducing the maintenance and electricity costs of the refrigeration unit.