- Phone
-
Address
Penghao Business District, Hanguang South Road, Yanta District, Xi'an City
Xi'an Zhantian Electronic Technology Co., Ltd
Penghao Business District, Hanguang South Road, Yanta District, Xi'an City
Application industry:Ultrasonic concentration meterIt can be used for concentration monitoring, purity control, product testing, quality control, hygiene concentration measurement, polymerization crystallization neutralization and separation process control, etc,
Ultrasonic concentration meters can be widely used in the sugar industry, dairy industry, food industry, paper industry, chemical industry, etc. They can measure concentration, density, viscosity, solid content, crystallinity, polymerization degree, sedimentation degree, sludge content, etc
Classification of ultrasonic concentration meters
There are two types of measuring probes for ultrasonic concentration meters:
There are two types of folding: insertion type and clip on type
working principle:
Ultrasonic concentration meterBy using the principle of ultrasound, process parameters such as liquid concentration or density are determined by measuring the sound velocity of the liquid. The ultrasonic concentration meter host pre stores temperature and sound velocity characteristic parameter curves for various media, and calculates the required process control parameters based on these curves. The ultrasonic concentration meter host is based on dual microprocessor digital signal processing technology, which can work stably and reliably even under harsh working conditions. It is very suitable for controlling complex process, with flexible input and output configuration, and temperature measurement can be completed through the built-in temperature probe.
Ultrasonic concentration meters can simultaneously measure and display concentration and flow rate. There are two types of measuring probes for ultrasonic concentration meters, one is plug-in and the other is clip on. When using a clamp probe, calibration is usually required. The plug-in probe is particularly suitable for concentration measurement in batch reactors and mixers, with precision and reliability. After factory calibration, there is no need to zero or set on site, and measurement can start immediately after installation.
Classification of ultrasonic concentration meters
There are two types of measuring probes for ultrasonic concentration meters:
Folding is a plug-in type
Insertion type ultrasonic concentration meter (Insertion type probe is particularly suitable for concentration measurement in batch reactors and mixers, accurate and reliable. After factory calibration, there is no need to zero or set on site, and measurement can be started immediately after installation)
Technical parameters of plug-in ultrasonic concentration meter:
Speed range: 300M/S... 000M/S
Accuracy: 0.03% reading plus or minus 0.04% M/S
Repeatability: 0.01% reading plus or minus 0.01M/s
Resolution: 0.005M/s
Temperature measurement: Resolution: 0.005K, Accuracy: 0.1K
Medium temperature: -20 degrees ...+140 degrees
Process connection: DIN flange
Material: Stainless steel 1.4571, titanium, Hastelloy 2.4605, etc.
The other type of folding is clip on
Clamp on ultrasonic concentration meter (usually requires calibration when using a clamp on probe).
Technical parameters of clamp type ultrasonic concentration meter:
Clamp on ultrasonic concentration meter
Speed range: 300M/S... 3000M/S
Accuracy: 0.25% reading plus or minus 0.1M/s
Repeatability: 0.15% reading plus or minus 0.1M/s
Resolution: 0.01M/s
Temperature range: -30 degrees ...+200 degrees (depending on the probe model)
Protection level: IP65 (special level IP68, please contact FLEXIM)
Caliber range: DN6... DN6500 (depending on probe model)
Pipeline material: All sound conducting materials