-
E-mail
3216820288@qq.com
-
Phone
13770421007
-
Address
Jinhu County Industrial Park, Jiangsu Province
Jiangsu Changshun Instrument Co., Ltd
3216820288@qq.com
13770421007
Jinhu County Industrial Park, Jiangsu Province
|
Clamp flowmeter
|
1、 Introduction to Clamp Flow Meter
CS-LWGY seriesClamp flowmeterIt is a new generation turbine flowmeter that has been optimized and designed based on domestic and foreign flow meter technology. It has the characteristics of simple structure, lightweight, high accuracy, good reproducibility, sensitive response, and easy installation, maintenance, and use. It is widely used to measure liquids in closed pipelines that do not corrode stainless steel 1Cr18Ni9Ti, 2Cr13, corundum AI2O3, and hard alloys, and have no impurities such as fibers or particles. The liquid has a kinematic viscosity of less than 5 × 10-6m2/s at working temperature. For liquids with a kinematic viscosity greater than 5 × 10-6m2/s, the flowmeter can be calibrated for real liquid before use If paired with display instruments with special functions, it can also perform quantitative control, over limit alarm, etc., making it an ideal instrument for flow measurement and energy saving. Sensors are precision flow measurement instruments that can be used to measure the flow and total amount of liquids when paired with corresponding flow accumulation instruments. Widely used in the fields of petroleum, chemical, metallurgy, scientific research and other metrology and control systems. Turbine flow sensors equipped with sanitary fittings can be applied in the pharmaceutical industry. The integrated turbine flowmeter has an explosion-proof design and can display the total flow rate, instantaneous flow rate, and flow saturation percentage. The battery adopts a long-lasting lithium battery, and the service life of a single function odometer battery can reach more than 5 years, while the service life of a multifunctional display meter battery can also reach more than 12 months. The integrated meter head can display a wide range of flow units, including cubic meters, gallons, liters, standard cubic meters, standard liters, etc. It can set fixed pressure and temperature parameters to compensate for gases. In situations where pressure and temperature parameters do not change significantly, this instrument can be used for fixed compensation accumulation. The technical performance of liquid turbine flow meters can be calibrated using real flow for hydraulic oil, engine oil, and small-diameter specifications with high viscosity.

2、 Characteristics:
◆ Low pressure loss, impeller has anti-corrosion function.
◆ It has high resistance to electromagnetic interference and vibration, reliable performance, and long working life.
The ultra-low power single-chip microcomputer technology used has strong overall functionality, low power consumption, and superior performance. Intelligent flow display with non-linear accuracy compensation function. The accuracy of the correction formula is better than ± 0.02%.
The instrument coefficient can be set online through buttons and displayed on an LCD screen, which is intuitive, clear, and highly reliable.
Adopting EEPROM for power down protection of accumulated flow and instrument coefficient. The protection period is greater than 10 years.
3、 Main technical parameters:
1. Nominal diameter: (4-200) mm. Basic parameters are shown in Table 1;
2. Medium temperature: (-20~80) ℃; Split type (-20~120) ℃;
3. Environmental temperature: (-20~55) ℃;
4. Accuracy: ± 0.5%, ± 1%;
5. Detector signal transmission line system: three wire voltage pulse (three core shielded cable);
6. Power supply: Voltage: 12V ± 0.144V, Current: ≤ 10mA;
7. Output voltage amplitude: High level ≥ 8V, low level ≤ 0.8V;
8. Transmission distance: The distance from the sensor to the display instrument can reach 1000m;
9. On site display power supply: 3.6V (powered by lithium battery, can be used continuously for more than 3 years);
10. Display mode: On site LCD displays instantaneous flow and cumulative flow;
11. On site display with signal output power supply: 24V; 4-20mA two-wire current output;

4、 Basic parameters
|
Execution standards |
Turbine flow sensor (JB/T9246-1999) |
|
Instrument caliber and connection method |
4. 6, 10, 15, 20, 25, 32, 40 are connected by threads (15, 20, 25, 32, 40) 50, 65, 80, 100, 125, 150, 200 are connected by flanges |
|
accuracy class |
± 1% R, ± 0.5% R, ± 0.2% R (to be customized) |
|
Range ratio |
1:10; 1:15; 1:20 |
|
Sensor material |
304 stainless steel, 316 (L) stainless steel, etc |
|
Conditions of Use |
Medium temperature: -20 ℃~+120 ℃ Environmental temperature: -20 ℃~+60 ℃ Relative humidity: 5%~90% Atmospheric pressure: 86KPa~106KPa |
|
Signal output function |
Pulse signal, 4-20mA signal |
|
Communication output function |
RS485 communication, HART protocol, etc |
|
Working power supply |
A. External power supply:+24VDC ± 15%, ripple ≤ ± 5%, suitable for 4-20mA output, pulse output, RS485, etc B. Internal power supply: 1 set of 3.0V10AH lithium batteries, which can work normally when the battery voltage is between 2.0V and 3.0V. |
|
Signal line interface |
Basic type: Hosman connector or built-in three core cable; Explosion proof type: Internal thread M20 × 1.5 |
|
Explosion proof grade |
ExdIIBT6 or ExdIICT4 |
|
protection grade |
IP65 or higher (customizable) |
2. Flow range and working pressure
|
Instrument caliber (mm) |
Normal flow range (m3/h) |
Expand flow range (m3/h) |
Conventional connection method Compared to the withstand voltage level |
Specially designed pressure resistance level (MPa) (Flange clamping) |
|
DN 4 |
0.04~0.25 |
0.04~0.4 |
Threaded connection/6.3MPa |
10. 16, 25 |
|
DN 6 |
0.1~0.6 |
0.06~0.6 |
Threaded connection/6.3MPa |
10. 16, 25 |
|
DN 10 |
0.2~1.2 |
0.15~1.5 |
Threaded connection/6.3MPa |
10. 16, 25 |
|
DN 15 |
0.6~6 |
0.4~8 |
Threaded connection/6.3MPa Flange connection/2.5MPa |
4.0, 6.3, 10, 16, 25 |
|
DN 20 |
0.8~8 |
0.45~9 |
Threaded connection/6.3MPa Flange connection/2.5MPa |
4.0, 6.3, 10, 16, 25 |
|
DN 25 |
1~10 |
0.5~10 |
Threaded connection/6.3MPa Flange connection/2.5MPa |
4.0, 6.3, 10, 16, 25 |
|
DN 32 |
1.5~15 |
0.8~15 |
Threaded connection/6.3MPa Flange connection/2.5MPa |
4.0, 6.3, 10, 16, 25 |
|
DN 40 |
2~20 |
1~20 |
Threaded connection/6.3MPa Flange connection/2.5MPa |
4.0, 6.3, 10, 16, 25 |
|
DN 50 |
4~40 |
2~40 |
Flange connection/2.5MPa |
4.0, 6.3, 10, 16, 25 |
|
DN 65 |
7~70 |
4~70 |
Flange connection/2.5MPa |
4.0, 6.3, 10, 16, 25 |
|
DN 80 |
10~100 |
5~100 |
Flange connection/2.5MPa |
4.0, 6.3, 10, 16, 25 |
|
DN 100 |
20~200 |
10~200 |
Flange connection/1.6MPa |
2.5, 4.0, 6.3, 10, 16, 25 |
|
DN 125 |
25~250 |
13~250 |
Flange connection/1.6MPa |
2.5, 4.0, 6.3, 10, 16 |
|
DN 150 |
30~300 |
15~300 |
Flange connection/1.6MPa |
2.5, 4.0, 6.3, 10, 16 |
|
DN 200 |
80~800 |
40~800 |
Flange connection/1.6MPa |
2.5, 4.0, 6.3, 10, 16 |
| Selection Table: |
|
Model number |
Explanation |
|||||||
|
CS-LWGY |
□ |
/□ |
/□ |
/□ |
/□ |
/□ |
/□ |
|
|
Nominal Diameter |
4 |
|
|
|
|
|
|
4mm |
|
6 |
6mm |
|||||||
|
10 |
10mm |
|||||||
|
15 |
15mm |
|||||||
|
20 |
20mm |
|||||||
|
25 |
25mm |
|||||||
|
32 |
32mm |
|||||||
|
40 |
40mm |
|||||||
|
50 |
50mm |
|||||||
|
65 |
65mm |
|||||||
|
80 |
80mm |
|||||||
|
100 |
100mm |
|||||||
|
125 |
125mm |
|||||||
|
150 |
150mm |
|||||||
|
200 |
200mm |
|||||||
|
Instrument Type |
N |
Sensor type:+12V or 24V power supply, output three wire pulse signal |
||||||
|
A |
Transmitter type:+24V power supply, output two-wire 4-20mA |
|||||||
|
B |
Intelligent type: Powered by lithium batteries, no signal output displayed on site |
|||||||
|
C |
Intelligent type:+24V power supply, on-site display and output of two-wire 4-20mA |
|||||||
|
C1 |
Intelligent type:+24V power supply, on-site display with RS485 communication protocol |
|||||||
|
C2 |
Intelligent type:+24V power supply, on-site display with HART communication protocol |
|||||||
|
accuracy class |
05 |
Level 0.5 |
||||||
|
10 |
Level 1.0 |
|||||||
|
02 |
0.2 level (negotiated ordering, longer production cycle) |
|||||||
|
Turbine type |
W |
Expand measurement range |
||||||
|
S |
Standard measurement range |
|||||||
|
Instrument material |
S |
304 stainless steel |
||||||
|
L |
316 (L) stainless steel |
|||||||
|
Explosion proof grade |
N |
Non explosion proof type |
||||||
|
E |
Explosion proof type, Exd Ⅱ BT6 |
|||||||
|
pressure rating |
N |
Conventional (refer to Table 2) |
||||||
|
H(x) |
High voltage (refer to Table 2) |
|||||||