Welcome Customer !

Membership

Help

Beijing Dongfang Langrui Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Beijing Dongfang Langrui Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    Jiajie, No. 20 Kechuang 14th Street, Beijing Economic and Technological Development Zone; 2nd Floor, Unit 4, Building 16, BDA Enterprise Hui

Contact Now

Chromatography column CE553-C18-P-Pearl Tongluo Pill

NegotiableUpdate on 05/10
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Caprisil C18-P dual tail sealing treatment can effectively mask residual silanol groups on silica gel, reducing their effects and resulting in a good peak shape. Through ultra-high density bonding, this product also has a wide pH range (1.5-10), and has good separation effects on strongly alkaline compounds, especially traditional Chinese medicine substances, making it more suitable for routine analysis. The chromatographic column CE553-C18-P-Pearl Tongluo Pill adopts double tail sealing technology to achieve good peak shape; $r $n ● Wide pH range, achieving good durability.

Product Details

MORHCHEM is a professional manufacturer of consumables related to chromatography columns. The company's headquarters is located in California, USA. After more than 30 years of continuous innovation and challenges, it has developed Caprisil,NexHgel,ItolSep,Guard column,Synersorb,Spherigel,HyperStar,Prep,CapriChiarl A series of HPLC chromatography columns.

MORHCHEM is committed to helping customers solve various challenges encountered in the field of analytical chemistry, from routine testing to complex research and development projects. Our clients include pharmaceutical and biotech companies, clinical diagnostic laboratories, universities, research institutes, and government agencies.


Chromatography column CE553-C18-P-Pearl Tongluo Pill


Caprisil C18-P dual tail sealing treatment can effectively mask residual silanol groups on silica gel, reducing their effects and resulting in a good peak shape. Through ultra-high density bonding, this product also has a wide pH range (1.5-10), and has good separation effects on strongly alkaline compounds, especially traditional Chinese medicine substances, making it more suitable for routine analysis.

Adopting double tail sealing technology to achieve good peak shape;

● Wide pH range, achievinggoodDurability.

色谱柱CE553-C18-P-Pearl Tongluo Pill


Chromatography column CE553-C18-P-Pearl Tongluo Pill


Chromatography column: CE553-C18-P

Flow rate: 1ml/min

Injection volume: 10ul

Mobile phase: Acetonitrile: Water (15:85)

Detector: 238nm


Sample spectrum:


色谱柱CE553-C18-P-Pearl Tongluo Pill



Instructions for using reverse phase chromatography column


1、 Conventional flushing method under mobile phase conditions

1. Before use: If methanol water or acetonitrile water is used as the mobile phase, the sample can be directly equilibrated with the mobile phase for 40 minutes before baseline stabilization.

2. After use: Rinse with pure methanol or acetonitrile water (70:30) for more than 40 minutes and store.

2、 The mobile phase contains buffer salts

1. Transition before use: Transition with 90% water and organic phase for 40-60 minutes. Then, after 40 minutes of equilibration under mobile phase conditions, the sample is taken (if under gradient conditions, the initial gradient equilibrium is followed).

2. Rinse after use: Rinse with 90% water and organic phase for at least 60 minutes. Then rinse with pure methanol or acetonitrile water (70:30) for more than 40 minutes and store.

3、 The mobile phase contains ion pair reagents

1. Transition before use: Transition with 90% water and organic phase for 40-60 minutes. Then equilibrate the sample under mobile phase conditions for 120 minutes (if it is under gradient conditions, follow the initial gradient equilibrium).

2. Rinse after use: Rinse with 90% water and organic phase for at least 180 minutes. Then rinse with pure methanol or acetonitrile water (70:30) for more than 40 minutes and store.

Note:

1.Factory storage conditions:7030=Acetonitrile: Water.

2.It is recommended to use a dedicated column for chromatography columns containing ion pair reagents.

3.It is recommended to store it in the factory solvent condition for long-term non use, and it is strictly prohibited to store it in a mobile phase containing salt.