Central air conditioning microcomputer control laboratory equipment (with microcomputer interface)

NegotiableUpdate on 11/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

DB-JD03B Central Air Conditioning Microcomputer Control Laboratory Equipment (with microcomputer interface) The central air conditioning system consists of one or more cold and heat source systems and multiple air conditioning systems

Product Details

DB-JD03B Central Air Conditioning Microcomputer Control Laboratory Equipment (with microcomputer interface)
中央空调微机控制实验室设备

The central air conditioning system consists of one or more cold and heat source systems and multiple air conditioning systems. The principle of liquid vaporization refrigeration is used to provide the required cooling capacity for the air conditioning system, in order to offset the thermal load of the indoor environment; The heating system provides the required heat for the air conditioning system to offset the indoor cooling load. The refrigeration system is a crucial part of the central air conditioning system, and its types, operating modes, structural forms, etc. directly affect the economy, efficiency, and rationality of the central air conditioning system during operation.

1、 Significant features of central air conditioning laboratory equipment:
1. Using fully transparent materials, the mold is molded in one go, with strong intuitiveness, which is helpful for teaching.
2. The overall design is reasonable, the appearance is beautiful, it is simulated, and the volume is small.
3. Both the refrigeration system and the heating system are equipped with multi-level protection measures to ensure the safe and reliable operation of the equipment.
4. The refrigeration system is made of all copper material, which has good efficiency and long service life.
5. Fully functional, capable of both cooling and heating, with a simulation demonstration system and all fault settings.
6. Equipped with a microcomputer communication interface, it facilitates remote control of the working status of experimental equipment and collection of multiple related data.
Main technical parameters:
Working power supply: single-phase three wire 220V ± 5% 50Hz
Dimensions: 240cmX110cmX190cm
Power consumption of the whole machine: cooling 2.5KVA
Heating 1.6KVA
Refrigerant: R22
Heating method: Electric heating (adjustable)
2、 Characteristics and working principles of each main component
1. Compressor:
The system adopts a fully enclosed piston compressor, with a normal operating temperature of only 0 ℃, which is safe and reliable, compact in structure, low in noise, and good in sealing. The refrigerant is R22.
2. Evaporator:
The refrigeration system adopts a transparent water tank evaporator, which is easy to observe and clear at a glance. The evaporator group is immersed in water, and the formulation evaporates in the tube. The water flows in the water tank under the action of the water pump to enhance the refrigeration effect.
3. Condenser:
The refrigeration system adopts a spiral tube condenser, which is a relatively new type of heat exchange equipment. It is made of two parallel copper coils and is a spiral body with two spiral channels. The middle spiral is the cooling water channel, and the outer spiral is the channel for high-pressure refrigerant.
4. Spray cooling tower:
The condensation method of this device adopts a counterflow cooling tower, with a mold formed in one go and a fully transparent structure. The suction fan is installed at the top of the tower, and the structure is fully simulated and intuitive; The cooling tower adopts suction type forced ventilation, and the tower is filled with fillers to improve the cooling effect; The warm water coming out of the condenser is pumped into the top of the tower by the cooling water pump and sprayed downwards by the nozzle of the water distributor.
5. Boiler:
The boiler is the core component of the central air conditioning heating system, which uses Ingrid electric heating tubes to completely isolate water and electricity. It has over temperature protection, anti dry burning protection, and over pressure protection to ensure human and machine safety; Adopting imported polyurethane foam insulation technology, the insulation performance is good.
6. Simulated Room:
The simulated room is made of fully transparent organic glass, which has a beautiful and compact appearance, occupies a small area, and has a compact structure; Featuring a fully transparent structure, it is easy to see at a glance; The room is equipped with coils, coil fans, and temperature control regulators.
7. Temperature control:
On the panel of this equipment experimental platform, there is a temperature control display device that can control the temperature range and has a circuit to detect the temperature of various key parts.
8. Simulation demonstration:
The device is equipped with a 500mm × 300mm system work demonstration board, which uses epoxy copper-clad board and four-color (red, green, blue, yellow) LED images to realistically display the temperature and working status of cold and hot pipes.
9. Temperature controller:
Two simulated rooms are equipped with temperature control regulators with digital displays, and the temperature range can be set by oneself. The instrument can automatically adjust the temperature according to the specific situation of the room temperature setting to reach the set value.
10. High and low voltage protection devices:
For safety reasons, the refrigeration system is equipped with high and low pressure protection relays to protect the normal operation of the compressor and system.
11. Water tank:
To conserve water resources in the recycling system; Complete tasks such as adding medium water, automatic adjustment, and filtration by adding a water tank; And it is equipped with an automatic water addition system. If the system lacks water resources, the water addition system will automatically start replenishing.
12. Central control section:
The overall control part of the experimental platform can complete tasks such as switching between cooling and heating of the equipment, as well as shutting down in cooling or heating state. The startup mode is all micro motion mode, using weak switch signals to control the microprocessor and drive the circuit to work, thereby extending the service life of the equipment.
13. Fault demonstration experiment:
The experiment can directly demonstrate twelve faults in the refrigeration system and three faults in the heating system, each with a separate demonstration switch.
14. Characteristics of microcomputer interface and control part:
There are two ways to control and display the parameters of the central air conditioning teaching experimental system. The first way is to control the working status of each part, set various parameters, and dynamically display them through the buttons on the control panel of the experimental platform. The second method is to communicate with the serial interface of the microcomputer through the serial port of the microcontroller (the motherboard of this experimental system uses advanced microcontrollers as the main chip), and is equipped with fully Chinese application software, so that all the control and display parameters required for the central air conditioning can be completed on the screen of the microcomputer.
<1> The software features are as follows:
(1) Dynamic display of temperature at various key points, including:
A、 Current heating value
B、 Current value of refrigeration
C、 Boiler import
D、 Boiler outlet
E、 Cooling tower inlet
F、 Cooling tower outlet
G、 Condenser inlet
H、 condenser outlet
I、 Evaporator inlet
J、 Evaporator outlet
K、 Simulated Room I
L、 Simulated Room II
(2) Temperature setting and display
The temperature setting can be freely selected between 0 and 99 degrees Celsius.
(3) Delay setting of compressor
The startup delay of the compressor can be set arbitrarily between 1-30 minutes.
(4) Switch control and indication
The operation and shutdown of various parts of the central air conditioning can be controlled through switches set on the microcomputer screen, and there is a switch display for remote operation. The switches are set as follows:
A、 cooling water pump
B、 cooling fan
C、 Refrigeration water pump
D、 compressor
E、 Electromagnetic valve I
F、 Electromagnetic valve II
G、 Heating water pump
H、 refrigeration
I、 heating
J、 shutdown
(5) Communication status display
Equipped with communication status and interface display between experimental system and microcomputer.
(6) Communication port selection
The communication port between the experimental system and the microcomputer has two optional serial ports, namely COM1 port and COM2 port.
<2> Characteristics of software equipped with microcomputers:
The software features a fully Chinese menu, which is very convenient and intuitive to operate. With just a click of the mouse, you can control various switches and set various parameters. You can set and operate some functions without reading the instructions.
All the functions implemented through microcomputer software can also be achieved through the device of the experimental bench control panel.
Central air conditioning configuration list:

serial number name Specification Model unit quantity
1 compressor 5519 Taiwan 1
2 starter 5519 only 1
3 water heater 402 Taiwan 1
4 liquid reservoir 1kg a 1
5 condenser a 1
6 hand valve 1/4 only 2
7 High and low pressure gauge only 2
8 expansion valve only 1
9 relay high pressure only 1
10 fan a 1
11 Air conditioning refrigeration fan only 4
12 heat pump 12W 2K-8 Taiwan 1
13 Boosting pump (cold water pump) 12W 2-8 Taiwan 2
14 Electromagnetic valve (liquid) 10cm 220V only 1
15 Electromagnetic valve (water) Ф1/2 220V only 2
16 evaporator only 2
17 filter Ф10cm a 1
18 sight glass Ф10cm a 1
19 thermostat a 2
20 thermostat 0-999C only 1
21 time delay relay set 1
22 thermal resistor only 8
23 Working principle demonstration board block 1
24 Temperature indicator light board block 1
25 control circuit board block 1
26 Simulated Room set 2
27 Simulated boiler set 1
28 cooling tower a 1
29 water tank set 2
30 stainless steel frame set 1
31 Experimental operation platform 2400×1200×900mm Zhang 1
32 Microcomputer control interface deputy 1