Welcome Customer !

Membership

Help

Cangzhou Huayi Testing Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Cangzhou Huayi Testing Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    Chengdong Industrial Zone, Xian County, Cangzhou City, Hebei Province

Contact Now

Cement Autoclave Tester

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The cement autoclave tester is suitable for the GB/T 750 national standard and is used by cement production units, building materials research institutes, colleges and universities, and construction quality inspection departments to determine the adverse effects of Mg0 (magnesium oxide) in cement on its stability. The equipment accelerates the hydration of magnesite in clinker under high temperature and high pressure conditions to measure the uneven changes in cement volume that may be caused by the hydration of magnesite

Product Details

Cement Autoclave TesterApplicable to the national standard GB/T 750, it is an instrument used by cement production units, building materials research institutes, colleges and universities, and construction quality inspection departments to determine the adverse effects of Mg0 (magnesium oxide) in cement on cement stability. The equipment accelerates the hydration of periclase in clinker under high temperature and high pressure conditions to measure the uneven changes in cement volume that may be caused by periclase hydration



Cement Autoclave Tester

15.1 Kettle volume: 8.5L

15.2 Inner diameter of kettle body: Ø 159mm

15.3 Operating pressure range: 0-2.0MPa (adjustable)

15.4 Maximum operating pressure: 2.5MPa

15.5 Maximum working pressure: 3.0MPa

15.6 Standard boost time (0-2+0.05MPa; room temperature -215.7+1.3 ℃): ≈ 45-75min

15.7 Safety valve opening pressure: 3.0MPa

15.8 Pressure automatic control fluctuation range:<± 0.05Mpa

15.9 Pressure holding time setting range: 1~99h (adjustable)

15.10 Material of kettle body: All stainless steel. High quality thickened kettle body ensures experimental safety

15.11 Design of independent electronic control system to ensure constant pressure and stabilization of equipment, while limiting control pressure to prevent pressure overshoot.

15.12 Control mode: 7-inch color touch screen control

15.13 Rated voltage: 220V

15.14 Rated power: 1200+600

YZF-2ACement Autoclave Tester

1. Kettle volume~8.5L

2. Inner diameter of kettle body: ф 160mm

3. Maximum working pressure: 2.5Mpa

4. Standard boost time: -45~75min

5. The fluctuation range of automatic pressure control+0.05Mpa

6. Pressure holding time: 3h (adjustable)

7. Rated voltage: 220V

8. Rated power 1200+600W

9. Size: kettle body diameter 400 * 1120mm

10. Control cabinet 480 * 300 * 894mm

YZF-2C Touchscreen Cement Autoclave Tester

1. Kettle volume x8.5L

2. Inner diameter of kettle body: ф 156mm

3. Cement compressionWork pressure: 0.8~2.0Mpa(Continuously adjustable)

4. Standard boost time: -45~75min

5. (Boosting to 2.0MPA) The fluctuation range of automatic pressure control is+0.05Mpa

6. Pressure holding time: 10 minutes to 30 hours (can be continuously set)

7. Rated voltage: 220V

8. Rated power 1200W+600W

9. Safe temperature setting: 220 ℃ (adjustable)

10. Equipment size: 1000 * 630 * 1200mm

11. Pressure reduction time: no more than 10 minutes (from 2.0MPa to 0.1MPa)

12. Relief pressure of safety valve: 2.5MPa