Canadian Pro lab strain cryopreservation tube

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Canadian Pro lab strain cryovials are bottles containing small beads used for transporting and storing microorganisms. 25 small beads with marked colors are packaged and stored in a preservation tube containing a preservative. The beads are washed and bacteria are adsorbed on top, and the preservation tube is kept at -70 ° C during the storage period; C, When cultivation is needed, individual beads can be easily removed from the storage tube and directly streaked onto the microbial culture medium.

Product Details

Canadian Pro lab strain cryopreservation tube

Common ordering model specifications:

Model 1: PL.170/M (5 colors, 80 pieces/box) (Each storage tube contains 25 magnetic beads and storage solution)

Purpose:
Microbank ™ It is a bottle containing small beads used for transporting and storing microorganisms.

Introduction and Explanation:
The long-term preservation of microorganisms is a challenge, as organisms require low-temperature storage and the least possible interference. However, Microbank ™ Provided a preservation solution to address this issue.
purpose
25 small beads marked with colors are packaged and stored in a preservation tube containing a preservative. The beads are washed and bacteria are adsorbed onto them. The preservation tube is then kept at -70 ° C during the storage period. When cultivation is required, individual beads can be easily removed from the preservation tube and directly streaked onto the microbial culture medium.
operating steps
A. Prepare
1. Use a prepared label, label the tube with a barcode, and inoculate one organism per tube. (You can also refer to step 6).
2. Open the cap of the small tube under sterile conditions.
3. Take 3-4 samples of pure cultured small bacterial colonies (cultured for 18-24 hours) and inoculate them with a liquid preservative using a pipette buffer.
4. Cover the bottle cap and invert it 4-5 times to absorb microorganisms, without vortexing.
5. At this point, microorganisms will be adsorbed onto the beads, and the buffer solution needs to be poured out to make the inoculated beads as liquid free as possible, and the bottle cap should be closed.
6. Make a record or other record of the culture barcode provided on the bottle.
7. The cryovials used for storing vaccinations are kept at -70 ℃ for long-term effectiveness.
B. Recovery

1. Under sterile conditions, open the bottle cap and use sterilized inoculants or tweezers to remove a small bead. Cover the bottle cap and store it at low temperature as soon as possible. Excessive temperature changes can reduce the survival ability of organisms.
2. Small beads can be directly inoculated onto solid culture medium or dripped onto suitable liquid culture medium.
3. As a push storage, each storage tube can hold approximately 25 times the same possible number of cultures.
局限性
1 Microbank ™ Providing a method for long-term preservation of organisms.
2. In use, aseptic techniques must be proficient to continue ensuring the integrity of microorganisms
3 Microbank ™ The following conditions cannot be used before vaccination:
a. The tube shows any signs of leakage (frozen tube damage).
b. The cryovials are contaminated.
c. The expiration date of the tag has been exceeded.
4. Anyway, the small beads cannot be put back into the cryovial after being removed.
5 Microbank ™ Providing different colors for easy color recognition does not imply any changes in product functionality.
safety precautions
When manipulating hazardous cultures, a biosafety cabinet is required.
2. When abandoning or partially using cryovials, pay attention to biological hazard prevention.
3. When saving Microbank ™ In liquid nitrogen. Please note the following:
a. Ensure that the storage cap is tightened properly: excessive tightening can twist the silicone rubber seal inside the cap and cause leakage.
b. Ensure that the thread and cap of the storage tube are dry before sealing: liquid droplets in liquid nitrogen will damage the seal.
c. All Microbank ™ The storage tube should be kept frequently in the gas phase, above liquid nitrogen. If immersed, they can develop cracks or fractures when returned to room temperature.
d. When removing the storage tube from the liquid nitrogen tank, safety equipment such as gloves, protective face shields, etc. should be used
Packing:
Microbank ™ The packaging is 80 pieces per box.
keep in storage:
Before use, unused Microbank ™ Can be stored at 4 ° C or room temperature but avoid direct light. Stored in these microbanks ™ Can be used within the effective date marked on the product.

Canadian Pro lab strain cryopreservation tube