KleinwachterCPM-374 Charging Board Monitor Electrostatic Flat Plate Detector
KleinwachterCPM-374 Charging Board Monitor Electrostatic Flat Plate Detector
Charging pad monitoring device
Charge Plate Monitor
Item number: CPM-374
Brand: Kleinw ä chter
Origin: Germany
CPM-374 is a versatile charging pad monitor with a lightweight design,
Easy to move. It can work through a built-in battery or an external power source.
All functions of the instrument are operated through two buttons. LCD display screen display operation program
And the test results. The supporting control software can start/end testing and set testing parameters through computer control.
The software interface displays real-time test readings, generates curve graphs, prints and saves test results.
Charging pad test mode:
Test the ion balance and static dissipation time of the static eliminator (IEC 61340-5-1 standard)
Test the static decay time of the material (IEC 61340-2-1 standard, Method 2)
Test the static decay time of the material (SAE J1645 standard)
Voltage meter test mode:
→ Has MK11 and PLAY sub modes:
Test the static electricity level of human walking (EN 61340-4-5 and EOS/ESD S.3.1 standards)
Kleinwachter CPM-374 Charging Board Monitor Electrostatic Flat Plate Detector
CPM-374 Product Parameters
Metal plate size: 150mm x 150mm
System capacitance: 20pF
Display: 100 x 24mm, 2-row 16 bit LCD display screen
Test range
Charging pad mode: 0-99 seconds (0-1000V), timing resolution of 0.1 seconds
Voltage meter mode: 0-2kV (MK11) 0-4kV (PLATE)
Field strength meter mode: 0-200kV/m
PC interface: RS232, 9-pol. Sub-D terminal
Built in rechargeable battery: 7.2V, 1300mAh
Battery life: 4 hours
Power adapter: 230VAC to 12VDC
Working environment temperature: 0-40 ℃
Working environment humidity: 10-60%

Static eliminator ion balance and discharge time test (IEC 61340-5-1 standard)
The starting voltage can be set to 1000V~500V (gradually decreasing by 50V)
The end voltage can be set to 0-500V (set in increments of 50V)
The testing time for ion balance can be set to 0-10 minutes. The testing methods can be set to automatic, only measure positive voltage decay, and only measure negative voltage decay
The test data is saved in the instrument's memory and can also be connected to a computer to output real-time data and generate curve graphs