Developed to solve various difficulties in the determination of residues of four pesticides and their metabolites, CNWSep polar pesticide specific columns were used. The four pesticides and their metabolites, including glyphosate, have suitable retention, good peak shape, stable peak emission, and no residue, and the chromatographic column has good durability and stability; Applicable standards: GB 23200.122-2026 National Food Safety Standard Determination of Residues of Four Pesticides and Their Metabolites, including Glyphosate, in Plant Derived Foods by Liquid Chromatography Mass Spectrometry;

Product Details

Developed to solve various difficulties in the determination of residues of four pesticides and their metabolites, CNWSep polar pesticide specific columns were used. The four pesticides and their metabolites, including glyphosate, have suitable retention, good peak shape, stable peak emission, and no residue, and the chromatographic column has good durability and stability;
Applicable standards: GB 23200.122-2026 National Food Safety Standard Determination of Residues of Four Pesticides and Their Metabolites, including Glyphosate, in Plant derived Foods by Liquid Chromatography Mass Spectrometry;

parameter
● Separation mode: Anion exchange
Column tube material: PEEK
● pH range: 3-12
● Voltage endurance upper limit: 20MPa (1 MPa=10 bar=145 psi)
● Temperature upper limit: 60 ℃
Organic solvent compatibility: 0-100% methanol, acetonitrile, acetone, etc


CNWSepThe polar pesticide specific column is a newly developed product by Anpu Experimental, specifically designed for the detection of polar pesticides such as glyphosate, glufosinate ammonium, and their metabolitesA fixed chromatographic column can solve the problems of no retention, no peak, poor peak shape (tailing, wide peak), unstable peak time in polar pesticide determinationVarious difficulties such as residue.


newCNWSepThe preservation solution for polar pesticide columns is4.5mM Na2CO3Recommended for use before use0.8 mL/min 4.5mM Na2CO3 activation60min.Notes:1)Due toNa2CO3It is a non-volatile salt, and it is recommended to use it in a regular mannerHPLC(Disconnect the detector) orICInstrument (disconnect detector)Activation;2)Chromatography column connectionHPLCorICBefore using the instrument system, use it first0.8 mL/min 4.5mM Na2CO3Rinse the entire system (disconnect detection)Connect the device to the system in the direction indicated on the chromatographic column label;