Welcome Customer !

Membership

Help

Tianjin Runze Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Tianjin Runze Instrument Co., Ltd

  • E-mail

    market@ensoultech.com

  • Phone

    15611538392

  • Address

    401-501, Building 13, Huiying Industrial Park, Intersection of Zhonghuan West Road and Xiwu Road, Tianjin Airport Economic Zone

Contact Now

CHNS-O Element Analyzer

NegotiableUpdate on 01/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The EMA 502 CHNS-O elemental analyzer is an accurate and reliable solution for the determination of carbon, hydrogen, nitrogen, sulfur, and oxygen, suitable for industrial fields such as pharmaceuticals and life sciences, organic chemistry, petrochemicals and energy, environment, agriculture, food and feed.
Product Details

EMA 502CHNS-O Element AnalyzerIt is an accurate and reliable solution for the determination of carbon, hydrogen, nitrogen, sulfur, and oxygen, suitable for industrial fields such as pharmaceuticals and life sciences, organic chemistry, petrochemicals and energy, environment, agriculture, food and feed.

Integrated solution to broaden your analytical potential

(1)EMA 502CHNS-O Element AnalyzerIt is an accurate and reliable solution for the determination of carbon, hydrogen, nitrogen, sulfur, and oxygen, suitable for industrial fields such as pharmaceuticals and life sciences, organic chemistry, petrochemicals and energy, environment, agriculture, food and feed.

(2) The EMA 502 elemental analyzer CHNS-O analysis helps to determine the structure of unknown compounds and evaluate the structure and purity of synthesized compounds.

(3) According to the reference method, EMA 502 can perform CHNS and O measurements in just a few minutes without the need for any additional components or external modules.

(4) EMA 502 is a safe analyzer that does not require irritating chemicals or time-consuming analysis steps.

Universality and productivity, * comfortable operation

(1) The EMA 502 is designed to work 24/7, 365 days a year without human supervision, and has fast and simple daily maintenance.

(2) Processing up to 117 samples at once, EMA 502's outstanding electronic automatic sampler and microbalance are connected to a PC for direct weighing data transmission. It can directly transmit weighing data, so the efficiency is *, ensuring the highest sample flux.

(3) The carbon content of solid, semi-solid, and liquid samples analyzed by EMA 502 can reach up to 20 milligrams.

(4) With just a powerful instrument and quick configuration changes, one can successfully face various analytical challenges in elemental analysis.

(5) Easily set up and execute your CHNS analysis, and thenpassSwitch the connection panel to O mode.

Stable performance, validated accuracy, and tested reliability

(1) EMA 502 is a flexible and powerful analyzer designed to achieve reliability and high-quality accuracy.

(2) TCD detection technology ensures extremely accurate and reproducible results, with an RSD value of 0.2% (sulfamic acid).

(3) The results are automatically calculated by EMASoftTM software and receive real-time data from the EMA 502 elemental analyzer through gas chromatography columns and TCD. Even before checking the results, a comprehensive understanding of the analysis output can be obtained, providing a real-time view of the analysis process and path with high-quality performance throughout the entire instrument life cycle.

Utilizing EMASoft ™ Software usability and data security

(1)EMASoft ™ The software is a powerful VELP solution for controlling and operating the EMA 502 elemental analyzer.

(2)EMASoft ™ Featuring a user-friendly interface that displays all relevant information at a glance: results, database, and instrument operating conditions.

(3) Custom methods can be selected and created from pre installed method libraries. A simple calibration curve is created for all elements, allowing testing of any sample matrix without the influence of memory

(4) The EMA 502 software can be upgraded through the optional 21 CFR Part 11 software package, suitable for laboratories in the pharmaceutical, cosmetics, and food industries that require compliance with FDA regulations.

Supported by VELP Ermes cloud platform, achieve high efficiency and improve workflow

(1) The EMA 502 features connectivity options for the VELP Ermes IoT cloud platform, an intelligent laboratory solution that allows for reduced routine operations as your analysis can be monitored in real-time anytime, anywhere.

(2) You can manage multiple instruments, consumables, workflows, analyze data, and instrument working conditions using only a personal computer, smartphone, or tablet.

(3) Instant event and alarm notifications can inform the analysis situation, and the interruption of remote analysis ensures control over laboratory processes.

(4) Only allow specific personnel within the organization to access instruments and data, and decide whether you are willing to directly share information with VELP or authorized service centers to benefit from reduced diagnostic time and enhanced service support, thereby achieving the highest system uptime.

(5) Through VELP's Ermes cloud platform, CHNS-O's experimental experience has reached a new level.