△Multiple combinations of injectors:
Rich combinations of injection ports can be configured as follows:
PIP sampler+PIP sampler
SPL injector+SPL injector
SPL sampler+PIP sampler
SPL sampler+PIP sampler+PIP sampler
SPL injector+SPL injector+PIP injector
SPL sampler+six way valve sampler
PIP sampler+six way valve sampler
SPL injector+PIP injector+PIP injector+six way valve injector+ten way valve injector
SPL injector+SPL injector+PIP injector+six way valve injector+ten way valve injector
Note: PIP packed column sampler, SPL capillary sampler
Multiple detector combinations:
The configurable detector combinations are as follows:
FID detector+FID detector
TCD detector+TCD detector
FID detector+TCD detector
FID detector+ECD detector
FID detector+FPD detector
FID detector+TCD detector+converter
FID detector+FID detector+TCD detector+converter
FID detector+ECD detector+FPD detector
FID detector+ECD detector+NPD detector
FID detector+converter+ZD detector
Note: FID flame ionization detector, TCD thermal conductivity cell detector
ECD electron capture detector
FPD flame photometric detector, NPD nitrogen phosphorus detector, ZD zirconia detector
Pressure protection method: The carrier gas has pressure protection functionYes, the instrument will automatically operate when the gas pressure is below 0.1MpaCut off the power supply to effectively protect the safety of chromatographic column use
● Display mode: Fully tempered glass touch screen display
Communication interface: Ethernet, IEEE802.3 (optional module)Proposed output
● Temperature control area: Six channel temperature control
Temperature control accuracy: ± 0.1 ℃ - ± 0.2 ℃
● Temperature control range: Room temperature+8 ℃ -450 ℃, with 1 ℃For increments
● Program heating: 33rd order program heating, heating rate0.1-40 ℃/min, with increments of 0.1 ℃, initiallyTermination time range: 0-6000min, with 1min as the intervalIncremental.
● 外部事件:6通道外部事件
● Sample injector system: Installation quantity 3, single/double packed columns
Injection System (PIP)/Capillary Injection System (SPL)
Detector system: Installation quantity 3, FID/TCD/FPD /ECD/NPD
/ZD/PDHID
● Sample injector system (optional): valve injection system/liquid automaticsampler
● Pre processing system (optional): Headspace sampler, thermal analyzer,Blow and capture devices, etc
● External system connection: supports one key trigger start and relay conduction
Power supply: 220V 50HZ 2000W
△ Hydrogen flame ionization detector (FID):
Quality based detector
Suitable for trace analysis of organic compounds
Detection limit: Mt ≤ 5 × 10-12g/s (n-hexadecane-isooctane solution)
Noise: ≤ 5 × 10-14A
Drift: ≤ 1 × 10-13A/30min
● Linear range: ≥ 106
● Ignition method: automatic ignition
△ Thermal conductivity detector (TCD):
Concentration type detector
Constant analysis applicable to organic and inorganic gases
Sensitivity: S ≥ 3500mv • ml/mg (conventional)
5000mV • ml/mg (highly sensitive) (benzene toluene solution)
Noise: ≤ 0.01mv
Baseline drift: ≤ 0.03mv/30min
● Linear range: ≥ 104
Flame photometric detector (FPD):
Quality based detector
Suitable for trace analysis of sulfur-containing and phosphorus containing compounds
Detection limit: (S) ≤ 5 × 10-11g/s, (P) ≤
1×10-12g/s;
Noise: ≤ 0.03mv
Baseline drift: ≤ 0.2mv/30min
● Linear range: ≥ 103 (S), 102 (P)
△ Electron Capture Detector (ECD):
Radioactive ionization detector
Suitable for heteroatoms containing halogen elements such as N, O, and S
Trace analysis of compounds
● 放射性同位素: 63Ni
Activity: 370MBq (10mCi)
Detection limit: ≤ 1 × 10-14g/s
Noise: ≤ 0.03mv
Baseline drift: ≤ 0.2mV/30min
● Linear range: ≥ 103
△ Nitrogen phosphorus detector (NPD):
Quality based detector
Suitable for trace analysis of nitrogen-containing and phosphorus containing compounds
Detection limit: (N) ≤ 5 × 10-12g/s, (P) ≤
1×10-12g/s
Noise: ≤ 0.03mv
Baseline drift: ≤ 0.2mv/30min
● Linear range: ≥ 103 (N), 102 (P)
△ Zirconia detector (ZD):
Electrochemical detector
Suitable for trace analysis of H2, O2, CO, CH4
Detection limit: H2 and O2 ≥ 0.1 ppm
CO、CH4≥0.5 ppm