British Alpha Dew Point MeterFeatures:
User friendly design, functionality*
auto-calibration
RS 485 serial communication
British Alpha Dew Point MeterTechnical Specifications:
Measurement principle of Alpha dew point meter in the UK: alumina capacitance hygrometer
Range: -110 ℃~+20 ℃
Accuracy: ± 2 ℃
Protection level: IP 66
Certification: CE, Atex
Environmental temperature: storage, -50 ℃~+70 ℃; Operation, 0 ℃~+55 ℃
Working humidity: 10~95% RH, non condensing
Power supply: 220VAC, 50Hz, 7.5W
2 independent, freely programmable alarm relays
Linear current or voltage relay signal
The sensor connection line can be up to 1km long
Calibrate according to national or standard standards
Relay output: single point, double throw, 120/240V, 50/60Hz, 2A, internal isolation
Linear (relay) output: 0~5V, 0~10V, 1~5V, 2~10V, 4~20mA
Our company supplies Alpha dew point meters from the UK, which are imported dew point meters. For more information about Alpha dew point meters from the UK, please call us for consultation.
Introduction to Alpha Dew Point Meter in the UK
The British Alpha Dew Point Meter is an economical and practical online dew point meter used for continuous analysis of humidity in air or other gases. Adopting * supercapacitor ADHS/1000 sensor; The front panel specification is IP65, with a 4-digit LED display showing dew point readings in ℃ or ℉ units, with a range of -80 to+20 ℃ (-112 to+68 ℉). The distance between the sensor and the instrument can reach 1000 meters.
Features of Alpha Dew Point Meter in the UK:
High quality and low price, fast response, simple operation
Accuracy ± 2 ℃ (DP)
1/8 Din disk mounting specification, front panel specification IP65
Digital display of ℃, ℉ or ppm (v)
*Interchangeable sensors
Range -80 to+20 ℃ (DP)
High precision measurement circuit
Isolate 4-20mA output, two alarm values (view/adjust settings from the front panel)
Calibration conforms to national and international standards
Order information: Standard configuration: analyzer, sensor, sensor holder, and 2-meter sensor cable
Specification and parameters of Alpha dew point meter in the UK
Installation: Flat installation with IP65 front panel
Display: 4-digit LED 14.2mm high characters
Range: -80~+20 ℃ (DP) (-112 ℉~+68 ℉ or 0~1000ppm (v) factory setting options)
Resolution: 0.1 ℃, 0.1 ℉, or 0.1ppm (v)
Alarm: Two adjustable alarm relays. Contact rated at 7A @ 240VAC or 7A @ 30VDC
Output: 4-20mA
sensor
Model: ADHS/1000 alumina supercapacitor sensor with IP65 connector
Range: -80 ℃ to+20 ℃ (or -112 ℉ to+68 ℉)
Accuracy: ± 2 ℃ (DP)
Pressure: Maximum pressure of 50 bar (optional high-pressure model)
Cable: Standard provides 2-meter cable; Up to 1000 meters in length
Sensor Seat
Model: ADSH - Stainless Steel, 1/8
Working conditions: -10 ℃~+50 ℃, 10-90% RH non condensing
Voltage: 90-250VAC; 50/60Hz, 6VA (maximum)