Brand new Kracht flowmeter TM16HR320V genuine
Gear flowmeter is a high-precision type of flow meter. Its main job is to cut liquid substances into a unit volume of liquid through its own mechanical measuring elements, and it can perform high-quality work multiple times. That's why it is a high-precision flowmeter.
Gear flowmeter measures flow rate with a fixed volume, independent of the flow state and viscosity of the fluid. However, changes in viscosity can cause variations in the amount of leakage, and excessive leakage can affect measurement accuracy. As long as the machining accuracy and tight fit of each moving component are ensured, the elliptical gear flowmeter can prevent corrosion and wear during use. High measurement accuracy can be obtained, generally ranging from 0.5% to 1%, and can also reach up to 0.3% depending on the operating conditions.
Function:
1According to the principle of gear motor, measuring gears driven by liquid flow
2The gear operates without contact in the measuring chamber, and the bearing components use ball bearings or sliding bearings with low friction
3The motion information of the gear is obtained by two sensors installed on the cover plate without contact
4When the measuring device rotates one tooth product, the sensor emits a signal corresponding to the geometric tooth productVgzThe signal
5:This signal is converted into a square wave signal by a preamplifier
6Dual channel sampling can achieve better resolution and flow recognition
Product Features
1:For various applications,VCThe series has been classified according to specific media by distinguishing various clearances, bearings, and materials
2A broad measurement range can meet various specific needs
3Within the range, the measurement is not affected by viscosity
4Low pressure drop, high sensitivity measurement, high working pressure, low noise
5High precision measurement with excellent repeatability
6:Within a wide temperature range, the output signal is not affected by temperature
7High accuracy can still be maintained at the lower limit of low flow rate measurement range
8High operational reliability of electronic devices
9Pre amplifier terminal is easy to use
Brand new Kracht flowmeter TM16HR320V genuine
The reason for the error is that for volumetric flow meters, when the flow rate is small, the error is negative, but when the flow rate increases, it becomes positive and remains basically unchanged. This phenomenon is mainly caused by leakage in the gap between moving parts, which is obviously related to the gap, viscosity, front and rear pressure difference, as well as the time required to flow through a certain volume.
In order to reduce errors, the instrument has a lower limit for flow measurement, which means it should not operate at extremely low flow rates. However, if the flow rate of the flow instrument is too large, it will increase the speed of the moving parts and increase wear. Therefore, the upper limit of the allowed flow rate is often determined based on the allowable speed of wear. Therefore, the flow rate through a volumetric flowmeter is limited by upper and lower limits, and the range ratio is often selected between 5 and 10.
New model of Kracht flowmeter:
BT0BZ0CK51, B12 GDME, BT6BZ0CK51/04, KF10RG10 matching magnetic coupler (domestic)
VC12K3F1P2SH,VC0.2K1P1P2SH,VC0.04K1P1P2SH,VC0.4K1P1P2K5K
VC0.2K1P1P2K5K,TM34TFC040V,VC3K1F1P2SH+AS8-I-24
VC 0.025 P6 RS 新型号 VC 0.025 K2 P3 R2 SH,VC 1 K2 F3 P2 SH
AS8-RS-24, VC 0,04 K1 P1 P2 KX5V with stainless steel base plate+5M cable
VC 1 K1 P1 P2 KX5V with stainless steel base plate and 5M cable, VCA 0,2 U4 F4 R1 VH
VC0.025K1P1P2SH,VC0.2 K1 F1 P2 SH + MVC 0.2 R3 CO5*
TM16HR320V, VC 1 F1 PH new model VC1 K1 F1 P2 HH, SVC4K3F1S2SH
SPVM10A1G1A05,VC1F1PV (VC1K1F1P2VH),VC 0.1 K1 F1 P2 SH
VC0.025K2F3R2VH,VC0.025K2P3R2SH,VC0.025K2F3P2XH
VC 0.2K5F3R2SH,VC0.04K2Q3P2T5K,VC1K2Q3P2T1.5K
VC0.2K2Q3P2T5K,VC0.2K2P3P2K5K,VC0.04K2P3P2K5K
VC1K2P3R2K5K,VC0.04K1F1P2SM,VC0.2K1F1P2HH
VC5G1F1P2SH, VCA 0,2 FB R1V/148 discontinued, new model: VCA 0,2 U4 F4 R1 SH
VCA2M5F4R1SH/40, VC3F1PS now upgraded model: VC 3 K1 F1 P2 SH with 5M cable
VCA02U4F4R1SH,VC3G1F1P2SH,VC0.4K1F1P2XH,VCA0.04 K4 F3 R1 SH