Brain stereotaxic device

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The standard vernier ruler positioning device of the American Stolting company's rat brain stereotaxic device has a fixed accuracy of 0.1mm and can rotate 90 degrees vertically to lock the position at any time. The operating arm movement range of the single arm stereotaxic device (up and down, left and right, front and back) can reach 80mm. It can be optionally equipped with a microinjection pump, a microscopic camera device, a skull drill, and includes an 18 degree ear rod and a rat adapter.

Product Details

  Brain stereotaxic deviceIt is the use of a three-dimensional coordinate system defined by landmarks or other reference points outside the skull to determine the position of certain neural structures beneath the cortex, in order to perform targeted stimulation, destruction, injection of drugs, or guidance of potentials under non direct visual exposure. It is an important research equipment in the fields of neuroanatomy, neurophysiology, neuropharmacology, and neurosurgery, which can be used for the establishment of Parkinson's disease animal models, wire animal models, brain tumor animal models, learning and memory, neural stem cell transplantation, cerebral ischemia, and other research.

  

Stolting is an industry leader in the field of stereopositioning devices. Its professional technical details, classic design style, and detailed accessories and models can meet all the needs of different users. For more than 50 years, it has been the gold standard for stereopositioning devices

  

According to applicable animals, it can be divided into mouse type, rat type, large animal type, and universal type for mice and rats (New Standard)

  

According to specific configurations, it can be divided into basic type, Ultra Precise type, Rotating Elliptic type, Digital display type, and Motorized type

  

The rat stereotaxic device is an important research equipment in the fields of neuroanatomy, neurophysiology, neuropharmacology, and neurosurgery. It is used to perform targeted injection, stimulation, destruction, and potential guidance of neural structures. It can be used for the establishment of Parkinson's disease animal models, epilepsy animal models, brain tumor models, learning and memory, brain neural stem cell transplantation, cerebral ischemia, and other research.


1. Design concise
The time tested U-shaped frame design, sturdy structure, and adapter that can be used with all experimental animals ensure that this product is the choice for locators.
2. The ruler is easy to read
All rulers are positioned to read from an open U-shaped end, which is also the position of most scientists. The numbers on the ruler are large and easy to read. The ruler is laser engraved, which can achieve durability for all three rulers. The accuracy of the ruler has reached 100 μ m (standard type), 10 μ m (digital display type), and 1 μ m (fully automatic type).
3. Smooth movement
standard formBrain stereotaxic deviceAdopting three thread, it can achieve * * position positioning, with a smooth and linear positioning process.
4. * Adjustment
By guiding the thread, the operating arm can control the movement in the left, right, and up and down directions, and the front and back control is carried out through wedge-shaped tenons, which can move 80mm in each direction. The universal joint allows the operator to rotate the gripper up to 90 degrees in the up and down or left and right planes. The improved locking component allows the locator to be locked at any angle without sliding, and also provides 90 degree vertical locking.
The operator can move the operating arm or gripper outside the operating area by swinging the joint during the experiment, and then reliably return to * * when needed.
5. Easy electrophysiological operation
The brass sleeve integrated on the operating arm facilitates grounding and can be directly connected to the metal part of the operating arm, even to the gripper.
6. Strong scalability
Additional operating arms, injection devices, cranial drills, etc. can be added, and different fixators can be added as needed for various animals.
There are two specifications for rat ear canals -18 ° and 45 °. 18 ° ear rods are relatively easy to penetrate into animal ear canals and fix skulls, but in most cases, they can cause damage to animal eardrums, especially for animals that require long-term care. The 45 ° ear rod * is obtuse and generally does not cause significant damage, making it suitable for long-term testing.

  

Technical parameters:

Fixed accuracy of standard vernier ruler positioning instrument: 0.1mm
Can rotate 90 degrees vertically and lock position at any time
The range of movement of the operating arm (up and down, left and right, front and back) can reach 80mm
Optional micro injection pump, microscopic camera device, and cranial drill for use
Includes 18 degree ear rod and rat adapter.

All products of the company are used for scientific research experiments and cannot be used for medical purposes