Boiler water quality online analyzer-Silicate radical
Suitable for boiler feedwater, boiler water, circulating water, process water, and recycled water
The quality of boiler water isLine analyzer-Product Features
▪ Automatic control of reaction temperature, constant temperature measurement and calibration;
▪ Adopting photoelectric metering and dosing method can achieve precise measurement;
▪ Large capacity memory that can store measurement data for 5 years;
▪ Cold light source spectral measurement extends the service life of the light source;
▪ Automatically adjust the light intensity of the light source, and ensure the accuracy of the instrument measurement even after the light source attenuates;
▪ 7-inch touch sensitive color LCD screen, providing more intuitive operation and display;
Boiler water quality online analyzer-Performance indicators
monitoring factor |
Total iron |
Silicate radical |
phosphate radical |
sodium ion |
Hydrazine |
measurement range |
(0-1mg/L) Or(0-5mg/L), scalable |
(0-200 µ g/L) or(0-2000 µ g/L), expandable |
0-20.0mg/L, scalable |
(2.00~9.00pNa(229000µg/L~0.23µg/L) |
0-100.0 µg/L |
Instrument indication error |
standard solution≤0.2mg/L,not exceed±0.02mg/L |
±2%F.S |
±1%F.S |
±0.05pNaor±5µg/L |
±2%F.S |
standard solution≥0.2mg/L, not exceed±10%; |
|||||
heavy again sex |
not greater than5% |
not greater than1% |
not greater than1% |
/ |
not greater than1% |
measurement period |
shortest30minute |
shortest30minute |
shortest20minute |
real-time monitoring |
30minute |
stable fixed sex |
Baseline drift: using blank calibration, does not affect accuracy |
||||
Chemical drift |
not greater than1%reading/Month (varies depending on the stability of the reagent) |
||||
temperature sensor |
PT100 |
||||
Temperature measurement range |
(0.0~60.0)℃ |
||||
Temperature measurement accuracy |
±0.5℃ |
||||
Temperature compensation range |
(0.1~60.0)℃ |
||||
Isolate output signal and load |
4~20mA(RL<500) |
||||
Alarm contact capacity |
normally open contactAC220V/3A,DC24V/5A |
||||
Normal working conditions of the instrument |
a)Ambient temperature0~45℃ |
||||
Sample conditions |
b)Relative humidity: not greater than85% |
||||
traffic:100300mL/min | |||||
Temperature:(5~50)℃ |
|||||
pressure:14 KPa | |||||
Allowable solid content of water sample: not greater than5Microns (no gelatinous substances allowed, no grease) | |||||
power supply |
AC220V±10% 50Hz±0.5Hzpower:150W |
||||
Instrument dimensions |
720×460×300mm |
||||
Instrument opening size |
664×404mm |
||||