Item Number:
n 28-0000-01- Gas Endeavour III Standard Configuration (0.5 L Reactor)
n 28-0000-02- Gas Endeavour III Standard Configuration (1 L Reactor)
n 28-0000-03- Gas Endeavour III Animal Nutrition Edition (0.25 L Reactor)
n 28-0500-01- Gas Endeavour III DUO (1 L reactor)
n 28-0600-01- Gas Endeavour III MAX (1 L reactor)
n 29-0000-01- Gas Endeavour III Light Standard Configuration (2 L Reactor)
n 29-0500-01- Gas Endeavour III Light DUO (2 L reactor)
function
Improve work efficiency and measurement accuracy
Gas Endeavour III has revolutionized industry standards by significantly reducing the manpower required for testing, individual operational skill requirements, and reducing the risk of random errors caused by operations, surpassing traditional methods and competitive solutions. After easily completing the experimental preparation and setup, Gas Endeavour III can automatically execute the entire testing process until the end. Real time monitoring and easily accessible reports make the inspection of experimental data easy and simple, not only improving the efficiency and quality of data collection, but also greatly simplifying the entire testing operation.

Experience BPC®Advantages of Core
The Gas Endeavour III adopts advanced gas detection units from BP Instruments, and incorporates excellent human-machine interaction operability with BPC Core professional software. It has powerful data acquisition, real-time data analysis display, report output, and extremely convenient remote monitoring functions. Compared with other instruments, it is used for both batch experiments and continuous experiments, providing switchable multifunctionality. In addition, by combining the two measuring units of 2ml and 9ml, it is easy to switch and combine the optimal test configurations of two different resolutions according to usage needs on the software.
Embedded solution without external dependencies
Gas Endeavour III provides advanced embedded solutions that do not require external computer storage and data processing. With its built-in microcontroller, it can store and process gas volume and flow measurement data locally, ensuring the reliability and data security of equipment use. By eliminating dependence on external systems, it can prevent the risk of data loss due to computer system crashes or system upgrades. In addition, the device has a huge storage capacity, which can store 15 million data points and collect up to 130000 liters of gas per experiment.

AURORA ™ software
- Pre installed on Gas Endeavour III
Experience Aurora ™ Software features
Aurora ™ It is the software solution for BPC Instruments' latest generation laboratory analytical instruments, providing the best adaptability, accuracy, interoperability, and security confidentiality for Gas Endeavour III. With its professional and interactive design philosophy, device parameter settings, monitoring processes, and download results have become reliable and convenient. Aurora ™ Pre installed on Gas Endeavour III, no need to purchase a separate software license or install on an external computer.

Easy access anytime, anywhere
The remote access feature of Gas Endeavour III enables easy access and monitoring of experiments from any web browser on your preferred computer, tablet, or smartphone, anytime, anywhere. By using Ethernet switches, multiple instruments can also be connected together, easily doubling the number of test channels for Gas Endeavour III. With this feature, each Gas Endeavour can run as a standalone device or be connected in parallel to meet your actual needs.
Advanced and reliable mixing system
The Gas Endeavour III integrated mixing system is driven by a high-quality, multifunctional brushless stepper motor. This system can perform gentle, precise, and controllable mechanical stirring in a closed gas environment. And it has achieved excellent performance in different solid suspension liquid systems, winning the trust of many customers worldwide.

configuration
Gas Endeavour III offers two versions: the standard 18 channel version and the streamlined 9-channel Light version. It offers a total of seven configurations, including standard configuration with two reactor sizes to choose from, animal nutrition version, DUO, and Max package. Here are some commonly used configurations. For more detailed information about system configuration, please contact our product experts.
Gas Endeavour III Standard Edition
The Gas Endeavour III, with its reliable and convenient operation and modular design, combines the elegant appearance and functionality of Northern Europe to ensure quality and reliability.

Gas Endeavour III Animal Nutrition Edition
Experience the convenience and precision brought by Gas Endeavour III in changing animal nutrition research.

Gas Endeavour III Max 版
Designed specifically for users with diverse needs, Gas Endeavour III MAX provides all the necessary equipment and accessories to meet your needs for real-time online monitoring of gas production and consumption dynamics in batches or continuous experiments.

Application field
Gas Endeavour is a versatile solution suitable for multiple fields, including:
• In vitro digestibility study
• Monitoring hydrogen production
• Promote ethanol fermentation process
• Wastewater analysis
• Evaluate microbial activity
Technical Specifications
Training Unit - Standard Version
• The maximum number of reactors in the system: 18 or 9
• Reactor material: Glass
• Standard reactor capacity: 500 ml or 1000 ml
• Heating typeConstant temperature water bath
• size68 x 56 x 33 cm (constant temperature water bath)
• temperature controlUp to 60 ° C (140 ° F) with an accuracy of 0.2 ° C
• Reactor stirringMulti functional mechanical mixer, using brushless DC motor (adjustable interval, speed, and rotation direction), with a maximum speed of 220 revolutions per minute

Cultivation Unit - Animal Nutrition Edition
•Maximum number of reactors per system: 18 or 9
•Reactor material: Glass
•Standard reactor capacity:250 ml
•Heating typeConstant temperature shaker water bath
•size53 x 33 x 28 cm (constant temperature water bath)
•temperature controlUp to 99 ° C (210 ° F)

Carbon dioxide adsorption unit
•CO2 adsorption bottle18 and 9
•Capacity of carbon dioxide adsorption bottle: 250 ml
•Bottle holder size: 55 x 28 x 17 (two groups and one group)
•Recommended adsorbent solution3 M NaOH (including pH indicator *), 200ml per bottle (not included)
•Absorption efficiency:>98%
*The standard configuration of the instrument does not include recommended adsorption solution

BPC Core Core Unit
•working principleGas liquid displacement and buoyancy
•Number of gas measurement chamber units: 18 or 9
•unit size: 55 x 19 x 17 cm
•Built in sensorsTemperature, pressure, magnetic force, level gauge
•interfaceEthernet, power supply USB B、 motor control
•display screenOLED screen 2.8-inch 256 x 64
•shellAluminum alloy and plastic
•power supply: 12V DC/1.0A, 100-240V AC
•Applicable Environment: Indoor
•measuring mediumDeionized water and distilled water
•Operating temperature: 0 – 50℃
•Operating pressure: -50 – 50 mbar
•Diameter of inlet and outlet: ID: 2.4 – 2.6 mm; OD: 4.2 – 4.7 mm; Recommended tracheal diameter: Inner diameter ID: 4 mm; Outer diameter OD: 6 mm
•Measurement resolution:2ml or 9ml
•Testing capacityEach channel of the 9ml flow chamber unit can cumulatively measure 7200L of gas; Each channel of the 2ml flow chamber unit can cumulatively measure 1600L of gas
•measurement range: 1-6000 ml/h (9ml flow chamber unit); 0.2-1500 ml/h (2ml flow chamber unit)
•repetitivenessCV ≤ 1% (9ml flow chamber unit); CV ≤ 3% (2mlFlow chamber unit
•Applicable gasesNon corrosive gases (such as CH4, CO2, H2, N2, etc.)

Bipu Instrument (Zhejiang) Co., Ltd. provides you with information on the parameters, price, model, principle, etc. of the Gas Endeavour III microbial degradation respirator. The price is negotiable, and you can contact us for more related informationconsulting service