Welcome Customer !

Membership

Help

Shilian Boyan (Beijing) Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shilian Boyan (Beijing) Technology Co., Ltd

  • E-mail

  • Phone

  • Address

Contact Now

BioTech Fluid Systems 4

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

BioTech Fluid System consists of 4 BTF cone plate units arranged in parallel, each measuring 28 cm; #178; )Fully automated computerized bioreactor, ranging from 0 to approximately 100 dyn/cm #178; Different shear stress distributions and temperature control of the entire system.

Product Details

BioTech-Flow-System 4

5_A25T1}RNFS4_Q]37J{9PF.png

4aBTFCone plate unit (parallel arrangement, each28 cm²)Fully automated computerized bioreactor0 –about100 dyn/cm²Different shear stress distributions and temperature control of the entire system.

type

4aBTFCone plate unit (parallel arrangement, each28 cm²)Fully automated computerized bioreactor0 –about100 dyn/cm²Different shear stress distributions and temperature control of the entire system.

advantage

Generate high-precision shear stress distribution: for example, used as a calibration tool in fluid dynamics; The range of shear stress adjustment is 0 Up to about100 dyn/cm2.

Free adjustable flow profile: provides adjustable constant, pulsating, oscillating, and freely adjustable flow profiles

Easy to set up, lifetime use

Customer specific settings: individualBTFUnit and multi-channel settings, combined or not combined with control units and/Or software and/Or impedance spectroscopy, it can also be used inBSL 4Used in the laboratory

Transparency: Online observation of the investigated system, such as live cells

Long term experiment on continuous medium replacement

Computer controlled bioreactor: flexible software for easy data navigation, classification, and image acquisition for time-resolved image analysis

Multi channel setting: studying the manipulation and control of cells in the same channel under different shear stress levels during the same time period

Electrophysiological measurements (impedance spectroscopy): the barrier function of sheet-like cell layers (e.gTERCross cell resistance of epithelial cells or endothelial cells

Sealed chamber for cell culture (e.g. infection, hypoxia)


biotechnology

Cell matrix interaction

Cell adhesion measurement and cell release kinetics related to biomaterials or fixed/absorbing proteins

Measure protein absorption using TIRF analysis method


Microfluidic Dynamics

Wall shear stress sensor calibration equipment

Nano and Microfluidic DynamicsMPS3Calibration of Micro Column Shear Stress Sensor(S. LargeTheC. BridgesTheW. SchröderTheACCESS e.V. Aachen

Product

customizableBTFThe system meets the needs of customers